This research study experimentally the effect of air flow rate on humidification process
parameters. Experimental data are obtained from air conditioning study unit T110D. Results obtained
from experimental test, calculations and psychometrics software are discussed. The effect of air flow rate
on steam humidification process parameters as a part of air-conditioning processes can be explained
according to obtained results. Results of the steam humidification processes (1,2) with and without
preheating with 5A and 7.5A shows decreasing in dry bulb temperature, humidity ratio, and heat add to
moist air with increasing air flow rate, but humidification load, and total energy of moist air increase with
increasing air flow rate in the testing tunnel. The steam humidification process (1) with dehumidifying
coil shows increase in dry bulb temperature, humidity ratio, humidification load, and heat add to moist air
with increasing air flow rate in the testing tunnel, but the total energy decrease as air flow rate increase.
These obtained results can be beneficial for controlling comfort air-conditioning processes in buildings
This study presents a transient thermo-mechanical finite element framework for high-speed end milling of AISI 4340 steel. The model couples moving heat sources, rate- and temperature-dependent plasticity, and adaptive mesh refinement (AMR) triggered by temperature gradient, plastic strain rate, and contact pressure. It is integrated with a design of experiments/response surface methodology using cutting speed (VC), feed per tooth (fZ), radial depth of cut/width of cut (ae), axial depth of cut (ap), and coolant mode. Responses include peak interface temperature per tooth (Tpeak), predicted surface residual stress (?_xx^"surf" ), and depth of compressive residual stress layer (dcomp). Experiments provide X-ray diffraction-based surfac
... Show MoreThis research investigates the adsorption isotherm and adsorption kinetics of nitrogen from air using packed bed of Li-LSX zeolite to get medical oxygen. Experiments were carried out to estimate the produced oxygen purity under different operating conditions: input pressure of 0.5 – 2.5 bar, feed flow rate of air of 2 – 10 L.min-1 and packing height of 9-16 cm. The adsorption isotherm was studied at the best conditions of input pressure of 2.5 bar, the height of packing 16 cm, and flow rate 6 Lmin-1 at ambient temperature, at these conditions the highest purity of oxygen by this system 73.15 vol % of outlet gas was produced. Langmuir isotherm was the best models representing the experimental data., and the m
... Show MoreIn the present work, experimental tests was done to explain the effect of insulation and water level on the yield output. Linear basin, single slope solar still used to do this purpose. The test was done from May to August 2017 in Mosul City-Iraq (Latitude: Longitude: Elevation: 200 m, and South-East face). Experimental results showed that the yield output of the still increased by 20.785% and 19.864% in case of using thermal insulation at 4cm and 5cm respectively, also the yield output decrease by 15.134% as the water level increase from 4 to 5cm, with the presence of insulation and 14.147% without it. It has been conclude that the insulation and water level play important role in the process of passive
... Show MoreTendon is important structure of the human body, since it can sustain tensile loading. The primary function of this tissue is to stabilize the joints they attached to it during daily activities. As well as, tendon has viscoelastic properties that can determine their response to loading and restrict the potential of injuries. One of the major points that this paper works with is the study of the biomechanical behaviour of tendon in response to tensile loading to describe their biological behaviour. Also, conclude the mathematical expression that may illustrate the tendon behaviour. All of the experiments were made in Physiology laboratories / Medical College/ Al- Nahrain University on ten rats "Rattus Norvegicus" of [108- 360] gm weight f
... Show MoreThe ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is
... Show MoreTo study the qualitative changes in testis tissue after carbon tetrachloride (CCl4) administration and to determine whether citric acid (CA) has a protective effect against testis damage induced by CCl4. This study compared two types of CA by measuring the histoarchitecture of the testis and serum levels of progesterone, estrogen and testosterone on mice. One of the most produced organic acid is citric acid. In this study, CA produced by microbial fermentation using Aspergillus Niger 5mg/kg and derived from citrus limon 400mg/kg (lemon). Mice were treated with daily intraperitoneal (i.p.) injection for seven successive days after randomly separated into six groups: (1) control, (2) CCl4 (0.02%), (3) limon citric acid (400 mg/kg), (4) CCl4 (
... Show MoreThis paper presents the thermophysical properties of zinc oxide nanofluid that have been measured for experimental investigation. The main contribution of this study is to define the heat transfer characteristics of nanofluids. The measuring of these properties was carried out within a range of temperatures from 25 °C to 45 °C, volume fraction from 1 to 2 %, and the average nanoparticle diameter size is 25 nm, and the base fluid is water. The thermophysical properties, including viscosity and thermal conductivity, were measured by using Brookfield rotational Viscometer and Thermal Properties Analyzer, respectively. The result indicates that the thermophysical properties of zinc oxide nanofluid increasing with nanoparticle volume f
... Show MoreAbstract
One of the most suitable materials to be used in latent heat thermal energy storage system (LHTES) are Phase change materials, but a problem of slow melting and solidification processes made many researchers focusing on how to improve their thermal properties. This experimental work concerned with the enhancing of thermal conductivity of phase change material. The enhancing method was by the addition of copper Lessing rings in phase change material (paraffin wax). The effect of diameter for the used rings was studied by using two different diameters (0.5 cm and 1cm). Also, three volumetric percentages of rings addition (3%, 6% and 10%) were tested for each diameter. The discharging process was done with
... Show MoreGrass carp at a weight of 34.68 + 2 g were gradually exposed to four saline concentrations: tap water (0.1), 3, 6, 9, and 12 gm/litter, and the first concentration represented a control treatment. Fish were fed on a diet with a protein content of 30% for ten weeks. Results of the growth experiment showed that the feed conversion rate was 2.46, 3.58, 4.84, 6.77, and -8.56 in the first to fifth treatments, respectively, and the rate feed conversion efficiency was 40.65, 27. 93, 20.66, 14.77 and 11.68 %, while the protein intake was 22.38, 20.44, 18.86, 17.47 and 16.56 g in salt concentrations of 0.1, 3, 6, 9 and 12 g/L, respectively. In another experiment to study the effect of salt acc