Preferred Language
Articles
/
joe-2971
DYE REMOVAL FROM TEXTILE WASTEWATER BY COAGULATION USING ALUM AND PAC
...Show More Authors

Removal of solar brown and direct black dyes by coagulation with two aluminum based
coagulants was conducted. The main objective is to examine the efficiency of these
coagulants in the treatment of dye polluted water discharged from Al-Kadhymia Textile
Company (Baghdad-Iraq). The performance of these coagulants was investigated through
jar test by comparing dye percent removal at different wastewater pH, coagulant dose,
and initial dye concentration. Results show that alum works better than PAC under acidic
media (5-6) and PAC works better under basic media (7-8) in the removal of both solar
brown and direct black dyes. Higher doses of PAC were required to achieve the
maximum removal efficiency under optimum pH conditions for both dyes. It was
observed that under optimum conditions of pH and dose values, PAC was significantly
higher dye removal efficiency than alum for all dyes initial concentrations.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
Promoting Solar Cell Efficiencies via Employing Sliver- Carbon- Pomegranate Peel Nano System
...Show More Authors

In this work, a functional nanocomposite consisting of multi walled carbon nanotubes combined with nanoparticles of silver and Pomegranate peel extract (MWCNTs- SNPs -NPGPE) was successfully synthesized using ultra sonic technique. The nanocomposite has been characterized using Transmission electron microscope (TEM), XRD, Energy dispersive X-ray spectroscopy (EDS) UV-Vis and FTIR. The obtained results reveal that the MWCNTs-SNPs-NPGPE nanocomposite exhibits form of nanotubes with rough surfaces and containing black spots, which are the silver nanoparticles. The dimensions of this tube are 161 nm in length and 60 nm in width with nanoparticles of silver not exceeding 20 nm. The XRD pattern of the prepared MWCNTs-SNPs-NPGPE nanocomposite s

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Mar 02 2014
Journal Name
Baghdad Science Journal
Comparison of Properties of Various Heat Storage Fluids used with Evacuated Tube of Solar Water Heater
...Show More Authors

The aim of this work was to capture solar radiation and convert it into solar thermal energy by using a storage material and the heat transfer fluid like oil and water and comparison between them, we used the evacuated tube as a receiver for solar radiation, The results showed that the oil better than water as storage material and the heat transfer fluid and the effective thermal conductivity material and good for power level, rates and durations of charge and discharge cycles.

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Numerical Analysis of Double Diffusive Laminar Natural Convection in a Right Angle Triangular Solar Collector
...Show More Authors

A numerical study of the double-diffusive laminar natural convection in a right triangular solar collector has been investigated in present work. The base (absorber) and glass cover of the collector are isothermal and isoconcentration surfaces, while the vertical wall is considered adiabatic and impermeable. Both aiding and opposing buoyancy forces have been studied. Governing equations in vorticity-stream function form are discretized via finite-difference method and are solved numerically by iterative successive under relaxation (SUR) technique. Computer code for MATLAB software has been developed and written to solve mathematical model. Results in the form of streamlines, isotherms, isoconcentration, average Nusselt, and average Sherw

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Heavy Metals Pollution Assessment of the Soil in the Northern Site of East Baghdad Oil Field, Iraq
...Show More Authors

Twenty four soil samples were collected from different sites in north sector of East Baghdad oil field, Iraq , and analyzed to assess the impact of urbanization and industrialization essential pollution. The soil samples were analyzed for heavy metals (As, Cd, Cr, Cu, Hg, Ni, Pb, and Zn) by using inductively coupled plasma–mass spectrometry (ICP-MS). Mean concentration of heavy metals in soil samples follows this pattern: Zn > Ni > Cr > Cu >Pb > As> Cd> Hg. The results show significant variations (lower and higher) in the concentrations of heavy metals compared with local and world studies, this variation is attributed to the natural anthropogenic sources. The pollution of studied soil was assessed using many soil

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 30 2024
Journal Name
Iraqi Journal Of Science
Content Validity-Based Evaluation Criteria System for Siting Wind-Solar Plants
...Show More Authors

     The spatial assessment criteria system for hybridizing renewable energy sources, such as hybrid solar-wind farms, is critical in selecting ideal installation sites that maximize benefits, reduce costs, protect the environment, and serve the community. However, a systematic approach to designing indicator systems is rarely used in relevant site selection studies. Therefore, the current paper attempts to present an inclusive framework based on content validity to create an effective criteria system for siting wind-solar plants. To this end, the criteria considered in the related literature are captured, and the top 10 frequent indicators are identified. The Delphi technique is used to subject commonly used factors to expert judgme

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Iraqi Journal Of Physics
Effect of Carbon Nanoparticles on the Performance Efficiency of a Solar Water Heater
...Show More Authors

Carbon nanoparticles are prepared by sonication using carbon black powder. The surface morphology of carbon black (CB) and carbon nanoparticles (CNPs) is investigated using scanning electron microscopy (SEM). The particles size ranges from 100 nm to 400 nm for CB and from 10 nm to 100 nm for CNPs. CNPs and CB are mixed with silicon glue of different ratios of 0.025, 0.2, 0.05, and 0.1 to synthesis films. The optical properties of the prepared films are investigated through reflectance and absorbance analyses. The ratio of 0.05 for CNPs and CB is the best for solar paint because of its higher solar water heater efficiency and is then added to the silicon glue . Temperature of cold water and temperature of hot water in storage tank were ta

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Iraqi Journal Of Science
Computer Vision of Optimal Geometric Concentration Ratio for the Solar Ball Lens
...Show More Authors

      This research evaluates the optical properties of an inhomogeneous and non-paraxial system using a solar ball lens (SBL) as a new thermal solar concentrated collector. This evaluation is based on detecting a diacaustic curve in a straightforward and accurate manner, with the diagnostic relying on image processing as a computational tool using the MATLAB program rather than a complicated numerical analytic procedure. The circle of least confusion (CLC) of the (SBL), (Fluorinated ethylene propylene (FEP) polymer – water core), was calculated. Furthermore, the study evaluated the maximum geometrical concentration ratio (G C) of refracted solar radiation that can be captured by a receiver of the (SBL). Without energy losses due

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Performance Analysis of Four Conceptual Designs for the Air Based Photovoltaic / Thermal Collectors
...Show More Authors

The  thermal  and  electrical  performance  of  different  designs  of  air  based  hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
A Impact of High Voltage Direct Current Link on Transmission Line in Kurdistan Power System
...Show More Authors

Kurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Photonic Crystal Fiber Pollution Sensor based on Surface Plasmon Resonance
...Show More Authors

       In this work, a pollution-sensitive Photonic Crystal Fiber (PCF) based on Surface Plasmon Resonance (SPR) technology is designed and implemented for sensing refractive indices and concentrations of polluted  water . The overall construction of the sensor is achieved by splicing short lengths of PCF (ESM-12) solid core on one side with traditional multimode fiber (MMF) and depositing a gold nanofilm of 50nm thickness on the end of the PCF sensor. The PCF- SPR experiment was carried out with various samples of polluted water including(distilled water, draining water, dirty pond water, chemical water, salty  water and oiled water). The location of the resonant wavelength peaks is seen to move to longer wavelengths (red shift)

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (9)
Scopus Crossref