The present work presents a new experimental study of the enhancement of turbulent
convection heat transfer inside tubes for combined thermal and hydrodynamic entry length of one
popular “turbulator” (twisted tape with width slightly less than internal tube diameter) inserted for
fire tube boilers. Cylindrical combustion chamber was used to burn (1.6 to 7kg/h) fuel oil #2 to
deliver hot gases with ranges of Reynolds number (10500 to 21700), and (11400 to 24150) for both
empty and inserted tube respectively.A uniform wall temperature technique was used by keeping
approximately constant water temperature difference (25ºC) between inlet and exit cooling water in
parallel flow shell and tube heat exchanger. The test tube consisted of smooth carbon steel tube of
(2400mm) long and (52mm) internal diameter. This test tube instrumented to derive local heat
transfer coefficient and local flue gasses static pressure.The experimental results show that for the
same fuel consumption, twisted tape insert with (H/D = 11.15) enhanced the mean Nusselt number
in (75.2%), (68.8%), (49.8%), (40.3%), and (16.7%) for fuel consumption (7kg/h), (6.16kg/h),
(4.5kg/h), (3.24kg/h), and (1.6kg/h) respectively.A set of empirical correlations that permit the
evaluation of the mean Nusselt number (for developing and fully developed region), and average
Nusselt number (for developed region) for empty and inserted tube are generated for engineering
applications.
In this research the change in the distance of the two stars in two binary star systems (13.6+8)M8and (13+10)M8 was studied, through the calculations the value (rate of mass transfer) of the two phases of dynamical stages of mass which are mass loss and mass transfer has been extracted in its own way ,by extracting the value of the value of (the distance variation between the two stars) has been found only in the mass transfer stage by using mathematical model ,in mass loss stage and were calculated from the change and the difference between the values of each at different times of binary star system evolution ,it was found that the maximum values of and are in ma
... Show MoreEndothelin-I (ET-I) is one of the potent vasoconstrictors secreted from endothelial cells when needed. Many studies revealed the elevation of serum ET-I with human diabetes and microangiopathies. Since insulin resistance is a case of mixed diabetic and pre-diabetic cases, many risk factors beyond obesity and inflammation are proposed. The current study aims to demonstrate the association between serum ET-I and asymmetric dimethylarginine (ADMA) and insulin resistance in type 2 diabetes mellitus (T2DM). Sera of 73 subjects were enrolled currently (control= 35 subjects, and 38 with T2DM for more than 7 years), aged (40-60) years old, with distinct body mass index (BMI) ≤ 25 for control volunteers and (BMI) ≥ 25 for obesity and diabetes
... Show MoreIntroduction & Aim: Long-term diabetes mellitus (DM) is known to have a deleterious impact on bone health, resulting in change in bone mineral density, bone turnover, and bone quality, all of which increase the risk of fractures. The aim of. this study was to link immunological and pro-inflammatory cytokine (I.L-6, I.L-1, and TNF-alpha) markers in patients.with type 1 diabetes to Their connection to bones formation (sPINP) and bone resorption parameters (sCTX). Materials & Methods: This study included 80 patients suffering from T1DM in the age range of 20-45 years. The patients were assayed for their biochemical (Vitamin D and HbA1c), Immunological (IL-6, IL-1 and TNF-alpha) parameters, as well as bone formation and resor
... Show MoreComplexes reaction of Fe+2, Cd+2, Hg+2 and Ag+ with the 2-thiotolylurea were prepared in ethanolic medium with the (1:1) M:L ratio yielded a series of neutral complexes. The prepared complexes were characterized using flame atomic absorption, micoelemental analysis (C.H.N), chloride content (Mohr Method) , FT.IR and UV-Vis spectroscopic, as well as magnetic susceptibility and conductivity measurement. From the above data, the proposed molecular structure for Fe+2, Cd+2 and Hg+2 complexes are tetrahedral geometry while Ag+ complex is trigonal structure.
This paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation
... Show MoreThis experiment was holdup in A-Faris poultry farms from 1st March to 11 of Aprile 2019. (ACTH) hormone infusion was tested in this experiment on acid-base regulation in broiler chickens. For 7 days, osmotic pumps dispensed 8 IU of ACTH in saline/kg of BW/d, or the same volume of saline as in ACTH at 1 l/h. On days 0 and 14, after the beginning of the infusions, blood samples were obtained to establish a baseline. The plasma concentrations of Na+, K+, and Cl- were decreased, whereas the partial pressure of CO2, anion gap, corticosterone, mean corpuscular hemoglobin concentration, and blood concentrations of hemoglobin and HCO - were all elevated due to the ACTH administration. When given ACTH, neither blood pH nor plasma Ca2+ levels changed
... Show MoreThermal management has grown more and more problematic as electronic components continue to get faster and smaller. One of the passive two-phase cooling systems are Oscillating heat pipe (OHP) that have the capacity to transmit a significant quantity of thermal energy across long distances. Oscillating heat pipe is a device that has the potential to satisfy this developing requirement. An investigation into the effects of orientation, filling ratio, and heat load on the initiation and characteristics of oscillatory motion, combining numerical simulations with experimental validation. A copper tube with a 2 mm inner diameter and a 2 mm wall thickness is used to fabricate the OHP. The condenser, evaporator, and adiabatic sections are
... Show More