Preferred Language
Articles
/
joe-2892
LOW COST AUTOMATIC SUN PATH TRACKING SYSTEM
...Show More Authors

Solar tracking systems used are to increase the efficiency of the solar cells have attracted the attention of
researchers recently due to the fact that the attention has been directed to the renewable energy sources. Solar tracking systems are of two types, Maximum Power Point Tracking (MPPT) and sun path tracking. Both types are studied briefly in this paper and a simple low cost sun path tracking system is designed using simple commercially available component. Measurements have been made for comparison between fixed and tracking system. The results have shown that the tracking system is effective in the sense of relatively high output power increase and low cost.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 26 2021
Journal Name
Journal Of Electrical Engineering & Technology
ANFIS Based Reinforcement Learning Strategy for Control A Nonlinear Coupled Tanks System
...Show More Authors

View Publication
Scopus (14)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sun Mar 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of Methyl Green Dye onto Bamboo in Batch and Continuous System
...Show More Authors

Adsorption techniques are widely used to remove certain classes of pollutants from waters, especially those that are not easily biodegradable. Dyes represent one of the problematic groups. The removal of methyl green from waste water using bamboo was studied in batch and continuous system. In batch system equilibrium time and adsorption isotherm was studied at different concentrations (5, 10, 15, 20, 25 and 30 ppm) and 50 mg weight of adsorbent.
Langmuir and Freundlich equations were applied for adsorption isotherm data. Langmiur equation was fitted better than Freundlich equation (R2=0.984 for Langmuir equation).The maximum percentage dye removal obtained 79.4% and adsorption capacity was 15.5 mg/g. For continuous system the breakthr

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design and Implementation for optical fiber communication system using frequency shift coding
...Show More Authors

In this research, optical communication coding systems are designed and constructed by utilizing Frequency Shift Code (FSC) technique. Calculations of the system quality represented by signal to noise ratio (S/N), Bit Error Rate (BER),and Power budget are done. In FSC system, the data of Nonreturn- to–zero (NRZ ) with bit rate at 190 kb/s was entered into FSC encoder circuit in transmitter unit. This data modulates the laser source HFCT-5205 with wavelength at 1310 nm by Intensity Modulation (IM) method, then this data is transferred through Single Mode (SM) optical fiber. The recovery of the NRZ is achieved using decoder circuit in receiver unit. The calculations of BER and S/N for FSC system a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 18 2025
Journal Name
Journal Of Optical Communications
Enhancing of underwater wireless optical communication system based on single photon detector
...Show More Authors
Abstract<p>This work investigates a simulation model of an underwater optical wireless communication (UOWC) system. Several water scenarios are considered: Harbor I (HA-I), Harbor II (HA-II), Coastal Ocean (CO), Clear Ocean (CL), and Pure Sea (PU). A laser diode (LD) with modulation schemes (NRZ-OOK) transmits data at various speeds of 2.5 Gbps, 5 Gbps, and 10 Gbps. To identify the optical signal, a single-photon detection (SPD), APD and PIN photodiodes are utilized. The analytical evaluation of the performance is executed using Q-factor, received power and bit error rate (BER). According to the results, the PU achieved an underwater distance of 35.5 m, 35 m, 34.5 m, for data tran</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Design and study for transmitter system of laser Nd-YAG (1.06 ?m)
...Show More Authors

In this research , design and study a (beam expander) for the Nd – YAG laser with (1.06 ?m) Wavelength has been studied at 5X zoom with narrow diversion in the room temperature. by using (ZEMAX) to study the system. Evaluate its performance via (ZEMAX) outputs, as bright Spot Diagram via (RMS), Ray Fan Plot, Geometric Encircled Energy and the value of Focal shift. Then study the effect of field of view on the outputs in the room temperature.

View Publication Preview PDF
Crossref
Publication Date
Thu Oct 30 2025
Journal Name
Ieee Access
Optic Flow Estimation for Human Spine Movements Using a Motion Capture System
...Show More Authors

Human interaction technology based on motion capture (MoCap) systems is a vital tool for human kinematics analysis, with applications in clinical settings, animations, and video games. We introduce a new method for analyzing and estimating dorsal spine movement using a MoCap system. The captured data by the MoCap system are processed and analyzed to estimate the motion kinematics of three primary regions; the shoulders, spine, and hips. This work contributes a non-invasive and anatomically guided framework that enables region-specific analysis of spinal motion which could be used as a clinical alternative to invasive measurement techniques. The hierarchy of our model consists of five main levels; motion capture system settings, marker data

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Hybrid Solar Air Conditioning System using a New Control Strategy
...Show More Authors

Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the sola

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
Voltage Profile Enhancing Using HVDC for 132KV Power System: Kurdistan Case Study
...Show More Authors

Nowadays power systems are huge networks that consist of electrical energy sources, static and lumped load components, connected over long distances by A.C. transmission lines. Voltage improvement is an important aspect of the power system. If the issue is not dealt with properly, may lead to voltage collapse.  In this paper, HVDC links/bipolar connections were inserted in a power system in order to improve the voltage profile. The load flow was simulated by Electrical Transient Analyzer Program (ETAP.16) program in which Newton- Raphson method is used. The load flow simulation studies show a significant enhancement of the power system performance after applying HVDC links on Kurdistan power systems. Th

... Show More
View Publication Preview PDF
Scopus (6)
Scopus Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Implementation of Power System Stabilizer Based on Conventional and Fuzzy Logic Controllers
...Show More Authors

To damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. A suitable PSS model was selected considering the low frequencies oscillation in the inter-area mode based on conventional PSS and Fuzzy Logic Controller. Two types of (FIS) Mamdani and suggeno were considered in this paper. The software of the methods was executed using MATLAB R2015a package.

 

 

View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue Sep 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Salivary mucoepidermoid carcinoma, auclair vs brandwein grading system: A histopathological comparative study
...Show More Authors

Background: The grading systems of salivary mucoepidermoid carcinoma depend on different histologic and morphologic features. The aim of this study was to compare between Auclair and Brandwein systems according to their histologic criteria, and the type of cell predominant. Materials and Methods: Twenty-one case included hematoxylin-eosin (H&E) stained tissue slides that were diagnosed as MEC, originally categorized into low and high grade type regardless of the grading system, have meticulously undergone histopathologic review. The sample was graded according to criteria owing to Auclair and Brandwein methods. The predominant type of cells was determined by microscopic examination according to grade of tumor. Results: Regarding the

... Show More
View Publication Preview PDF
Scopus Crossref