Preferred Language
Articles
/
joe-2890
HYDRODESULFURIZATION OF THIOPHENE OVER COMO/ AL2O3 CATALYST USING FIXED- AND FLUIDIZED-BED REACTORS
...Show More Authors

The present work reports a direct experimental comparison of the catalytic hydrodesulfurization of
thiophene over Co-Mo/Al2O3 in fixed- and fluidized-bed reactors under the same conditions. An
experimental pilot plant scale was constructed in the laboratories of chemical engineering department,
Baghdad University; fixed-bed unit (2.54 cm diameter, and 60cm length) and fluidized-bed unit (diameter of 2.54 cm and 40 cm long with a separation zone of 30 cm long and 12.7 cm diameter). The affecting
variables studied in the two systems were reaction temperature of (308 – 460) oC, Liquid hourly space
velocity of (2 – 5) hr-1, and catalyst particle size of (0.075-0.5) mm. It was found in both operations that the
conversion increases with increasing of reaction temperature, slightly decreases with increasing of liquid
hourly space velocity and not affected by particle size. Also a kinetic analysis was performed for thiophene
hydrodesulfurization reaction in fixed bed reactor and the results indicate that the reaction kinetics are not affected by pore and film diffusion limitations. The results of the comparison between the two reactors indicate that a low conversion was obtained in a fluidized bed than in fixed bed over the range of conditions studied. The lower conversion can be attributed to the gas that bypasses the bed in the form of bubbles or channels.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Feb 28 2023
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The Importance of Using Concentrator Solar Energy Technologies in Anbar Province
...Show More Authors

The aim of the research is a techno-economic analysis of the use of concentrated solar energy technologies in the Iraqi city, considering the concentrated solar energy technology is a renewable energy technology that derives its resources from the sun and is replenished at a rate that exceeds its use. It is also inexhaustible and environmentally friendly energy from its environmental footprint, unlike traditional fossil energy which produces greenhouse gases and a major cause of global warming.

This research measures the costs of concentrated solar energy technology to Reduce the effects caused by other energies and work to fill part of the shortfall in the total electricity production, even at a specific percentage, in preparati

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Heavy Metals from Industrial Wastewater by Using RO Membrane
...Show More Authors

Industrial wastewater containing nickel, lead, and copper can be produced by many industries. The reverse osmosis (RO) membrane technologies are very efficient for the treatment of industrial wastewater containing nickel, lead, and copper ions to reduce water consumption and preserving the environment. Synthetic industrial wastewater samples containing Ni(II), Pb(II), and Cu(II) ions at various concentrations (50 to 200 ppm), pressures (1 to 4 bar), temperatures (10 to 40 oC), pH (2 to 5.5), and flow rates (10 to 40 L/hr), were prepared and subjected to treatment by RO system in the laboratory. The results showed that high removal efficiency of the heavy metals could be achieved by RO process (98.5%, 97.5% and 96% for Ni(II),

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Manufacture of Lead Acid Battery Separators using Locally Produced Polyethylene
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Dec 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Reducing of Corrosion Rate in Boiler Tubes by Using Oxygen Scavengers
...Show More Authors

The corrosion behavior of carbon steel at different temperatures 100,120,140 and 160 Cͦ under different pressures 7,10 and 13 bar in pure distilled water and after adding three types of oxygen scavengers Hydroquinone, Ascorbic acid and Monoethanolamine in different concentrations 40,60 and 80 ppm has been investigated using weight loss method. The carbon steel specimens were immersed in water containing 8.2 ppm dissolved oxygen (DO) by using autoclave. It was found that corrosion behavior of carbon steel was greatly influenced by temperature with high pressure. The corrosion rate decreases, when adding any one of oxygen scavengers. The best results were obtained at a concentration of 80 ppm of each scavenger. It was observed that 

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 08 2006
Journal Name
Journal Of Engineering
INFLUENCE OF DEFECT IN THE CONCRETE PILES USING NON-DESTRUCTIVE TESTING
...Show More Authors

This paper presents the results of experimental investigation carried out on concrete model piles to study the behaviour of defective piles. This was achieved by employing non-destructive tests using ultrasonic waves. It was found that the reduction in pile stiffness factor is found to be about (26%) when the defect ratio increased from (5%) to (15%). The modulus of elasticity reduction factor as well as the dynamic modulus of elasticity reduction factor increase with the defect ratio

Publication Date
Wed Sep 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Improving the Properties of Asphalt Concrete Mixtures Using Iron Filling Wastes
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Active Vibration Control of Cantilever Beam by Using Optimal LQR Controller
...Show More Authors

Many of mechanical systems are exposed to undesired vibrations, so designing an active vibration control (AVC) system is important in engineering decisions to reduce this vibration. Smart structure technology is used for vibration reduction. Therefore, the cantilever beam is embedded by a piezoelectric (PZT) as an actuator. The optimal LQR controller is designed that reduce the vibration of the smart beam by using a PZT element.  

In this study the main part is to change the length of the aluminum cantilever beam, so keep the control gains, the excitation, the actuation voltage, and mechanical properties of the aluminum beam for each length of the smart cantilever beam and observe the behavior and effec

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Evaluation The Performance Geodetic of the Receivers Using Static Positioning Technique
...Show More Authors

Global Navigation Satellite System (GNSS) is considered to be one of the most crucial tools for different applications, i.e. transportation, geographic information systems, mobile satellite communications, and others. Without a doubt, the GNSS has been widely employed for different scientific applications, such as land surveying, mapping, and precise monitoring for huge structures, etc. Thus, an intense competitive has appeared between companies which produce geodetic GNSS hardware devices to meet all the requirements of GNSS communities. This study aims to assess the performance of different GNSS receivers to provide reliable positions. In this study, three different receivers, which are produced by different manufactur

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Iron from Al-Hussainyat Iron Ore using Acid Leaching
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
International Journal Of Science And Research (ij
Simulation of Chlorine Decay in Al-Gukook WaterDistribution Networks Using EPANET
...Show More Authors

The approach of the research is to simulate residual chlorine decay through potable water distribution networks of Gukookcity. EPANET software was used for estimating and predicting chlorine concentration at different water network points . Data requiredas program inputs (pipe properties) were taken from the Baghdad Municipality, factors that affect residual chlorine concentrationincluding (pH ,Temperature, pressure ,flow rate) were measured .Twenty five samples were tested from November 2016 to July 2017.The residual chlorine values varied between ( 0.2-2mg/L) , and pH values varied between (7.6 -8.2) and the pressure was very weak inthis region. Statistical analyses were used to evaluated errors. The calculated concentrations by the calib

... Show More