The present paper describes and analyses three proposed cogeneration plants include back pressure steam-turbine system, gas turbine system, diesel-engine system, and the present Dura refinery plant. Selected actual operating data are employed for analysis. The same amount of electrical and thermal product outputs is considered for all systems to facilitate comparisons. The theoretical analysis was done according to 1st and 2nd law of thermodynamic. The results demonstrate that exergy analysis is a useful tool in performance analysis of cogeneration systems and permits meaningful comparisons of different cogeneration systems based on their merits, also the result showed that the back pressure steam-turbine is more efficient than other proposals. Moreover, the results of the present work indicate that these alternative plants can produce more electric power than that required in the refinery. At present time, the industrial cogeneration plants are recommended in Iraq, especially in petroleum industry sectors, in order to contribute with ministry of electricity to solve the present crisis of electric power generation. Such excess in the power can sold to the main electric network. The economic analysis are proved the feasibility of the proposed cogeneration plants with payback period of four year and six months ,three year and eight months, and ten years for steam cogeneration plant, gas turbine cogeneration plant and diesel engine cogeneration plant respectively.
An experiment was conducted at the laboratories of College of Agriculture – Kerbala University during 2016. The aim of this study was to the effect of water extracts of medicinal plants germination percentage and development of plumule and radicle growth .The completely randomized design with three replicates was usedin each experiment consisted of water extracts (T1= Distilled water),(T2= Eruca sativa Eruca sativa L),(T3= Fenugreek ïºï»Ÿïº¤ï» ﺒﺔTrigonella foenum - graecum L),(T4= Sweet FennelFoeniculum vulgare.Mill),(T5=Borage Anchusa strigosa Lab),(T6=Dill Anethum graveolens L) ,(T7=Black cuminNigella Sativa L),(T8=Cumin Cuminumcyminum L),(T9= CorianderCoriandrum sativum L. ). Results of Lab.
... Show MoreThis study was conducted in the botanical garden, Department of biology, College of Science / Mustansiriyah University in spring season, where the starts from (15 February to 15 March, 2019). Under the natural environmental conditions in the greenhouse in order to evaluate the effectiveness of some plant extracts as a promoter for rooting the apical stem cutting of rosemary plants at different concentrations compared with the IBA growth regulator. Plant extracts are Parsley (Petroselinum crispum), Dill (Anethum graveolens) and date palm fruits (Phoenix dactylifera) were used with concentrations (0, 1.25, 2.5 g / l). The IBA concentration was (100 mg / L) with dipping time 24 hour for all treatments. The following measurements were taken aft
... Show MoreAbstract
The catalytic cracking conversion of Iraqi vacuum gas oil was studied on large and medium pore size (HY, HX, ZSM-22 and ZSM-11) of zeolite catalysts. These catalysts were prepared locally and used in the present work. The catalytic conversion performed on a continuous fixed-bed laboratory reaction unit. Experiments were performed in the temperature range of 673 to 823K, pressure range of 3 to 15bar, and LHSV range of 0.5-3h-1. The results show that the catalytic conversion of vacuum gas oil increases with increase in reaction temperature and decreases with increase in LHSV. The catalytic activity for the proposed catalysts arranged in the following order:
HY>H
... Show MoreKA Hadi, AH Asma’a, IJONS, 2018 - Cited by 1
Iraqi crude Atmospheric residual fraction supplied from al-Dura refinery was treated to remove metals contaminants by solvent extraction method, with various hydrocarbon solvents and concentrations. The extraction method using three different type solvent (n-hexane, n-heptane, and light naphtha) were found to be effective for removal of oil-soluble metals from heavy atmospheric residual fraction. Different solvents with using three different hydrocarbon solvents (n-hexane, n-heptane, and light naphtha) .different variables were studied solvent/oil ratios (4/1, 8/1, 10/1, 12/1, and 15/1), different intervals of perceptual (15, 30-60, 90 and 120 min) and different temperature (30, 45, 60 and 90 °C) were used. The metals removal perce
... Show MoreFeedback on students’ assignments can be done in many different ways. Nowadays, the growing number of students at universities has increased the burden on the instructors to give feedback on students’ writings quickly and efficiently. As such, new methods of modern online automated feedback tools, such as Hemingway app and ecree,are used to assist and help instructors. Hence, this research is an explanatory study to examine the effect of using the online automated feedback on some Iraqi EFL learners’ writings at the university level. The study comprised 60 students enrolled in an English language course at the University of Anbar. They were divided randomly into two groups, experi
... Show MoreIraqi crude Atmospheric residual fraction supplied from al-Dura refinery was treated to remove metals contaminants by solvent extraction method, with various hydrocarbon solvents and concentrations. The extraction method using three different type solvent (n-hexane, n-heptane, and light naphtha) were found to be effective for removal of oil-soluble metals from heavy atmospheric residual fraction. Different solvents with using three different hydrocarbon solvents (n-hexane, n-heptane, and light naphtha) .different variables were studied solvent/oil ratios (4/1, 8/1, 10/1, 12/1, and 15/1), different intervals of perceptual (15, 30-60, 90 and 120 min) and different temperature (30, 45, 60 and 90 °C) were used. The metals removal percent we
... Show MoreThis research analyzes the level of the short circuit effect of the Iraqi super network and decides the suitable location for the High Voltage Direct Current (HVDC) connections in order to obtain the best short circuit reduction of the total currents of the buses in the network. The proposed method depends on choosing the transmission lines for Alternating current (AC) system that suffers from high Short Circuit Levels (SCLs) in order to reduce its impact on the transmission system and on the lines adjacent to it and this after replacing the alternating current (AC) line by direct current (DC) line. In this paper, Power System Simulator for Engineering (PSS/E) is used to model two types of HVDC lines in an effective regi
... Show MoreThis paper provides an attempt for modeling rate of penetration (ROP) for an Iraqi oil field with aid of mud logging data. Data of Umm Radhuma formation was selected for this modeling. These data include weight on bit, rotary speed, flow rate and mud density. A statistical approach was applied on these data for improving rate of penetration modeling. As result, an empirical linear ROP model has been developed with good fitness when compared with actual data. Also, a nonlinear regression analysis of different forms was attempted, and the results showed that the power model has good predicting capability with respect to other forms.