The removal of heavy metal ions from wastewater by sorptive flotation using Amberlite IR120 as a resin, and flotation column, was investigated. A combined two-stage process is proposed as an alternative of the heavy metals removal from aqueous solutions. The first stage is the sorption of heavy metals onto Amberlite IR120 followed by dispersed-air flotation. The sorption of metal ions on the resin, depending on contact time, pH, resin dosage, and initial metal concentration was studied in batch method .Various parameters such as pH, air flow rate, and surfactant concentration were investigated in the flotation stage. Sodium lauryl sulfate (SLS) and Hexadecyltrimethyl ammonium bromide (HTAB) were used as anionic and cationic surfactant respectively. The sorption process, which is PH dependent, shows maximum removal of metal ions at pH 7. Langmuir and Freundlich isotherm expressions were found to give both a good fit to the experimental data. Kinetic data correlated well with Lagergren second order kinetic model, and flotation step enhanced the removal efficiency of nickel and cadmium from wastewater from about 75% to 94% and reduce turbidity so it can dispense with the filtering process, which is expensive technology. It is believed that flotation separation has great potential as a clean water and wastewater treatment technology.
Salicylaldehyde was react with 4-amino-2,3-dimethyl-1-phenyl-3-pyrazoline-5-on to produce the Schiff base ligand 2,3-dimethyl-1-phenyl-4-salicylidene-3-pyrazoline-5-on (L). The prepared ligand was identified by Microelemental Analysis, and FT.IR, UV-Vis spectroscopic techniques. A new complexes of Fe(III),Co(II),Ni(II),Cu(II),Ce(III) and Pb(II) with mixed ligands of dithizone (DTZ) and Schiff base were prepared in aqueous ethanol with a 2:2:1 M:L:DTZ. The prepared complexes were characterized using flame atomic absorption, (C.H.N) Analysis, FT.IR and UV-Vis spectroscopic methods as well as magnetic susceptibility and conductivity measurements. In addition biological activity of the ligands and complexes against two selected type of bacteria
... Show MoreNew derivative molecular absorption spectrophotometric methods have been developed for the determination of Al (III) , Mn (II) , individually and binary mixtures . The aim of this model of study is to obtain analytical results characterized by adequate standard of analytical figures of merits through application of derivative Spectrophotometry (dnA/d?n). The two metals acetyl acetonates are chemically stable and are widely used as catalysts . Where Interferences are probable due to very close or nearby peaks or Summits, the Zero – Crossing derivative measurement technique is used to avoid interfering effects between two metals pairs.
Power switches require snubbing networks for driving single – phase industrial heaters. Designing these networks, for controlling the maximum allowable rate of rise of anode current (di/dt) and excessive anode – cathode voltage rise (dv/dt) of power switching devices as thyristors and Triacs, is usually achieved using conventional methods like Time Constant Method (TCM), resonance Method (RM), and Runge-Kutta Method (RKM). In this paper an alternative design methodology using Fuzzy Logic Method (FLM) is proposed for designing the snubber network to control the voltage and current changes. Results of FLM, with fewer rules requirements, show the close similarity with those of conventional design methods in such a network of a Triac drivin
... Show MoreIn recent decades, there has been increasing interest in wastewater treatment because of its direct impact on the environment and public health. Over time, other forms of treatment have been developed and modified, including extended aeration. This process is included in the suspended growth system. In this paper, a comparative study was conducted between the efficiency of the extended aeration plant and that of the trickling filter plant in removal of BOD and COD. The method of comparison was done by knowing the value of the pollutant before and after the treatment and then extract the removal ratio of each pollutant within each plant. The results showed that the percentage of removal of BOD in the trickling filte
... Show MoreIn developing countries, conventional physico-chemical methods are commonly used for removing contaminants. These methods are not efficient and very costly. However, new in site strategy with high treatment efficiency and low operation cost named constructed wetland (CW) has been set. In this study, Phragmites australis was used with free surface batch system to estimate its ability to remediate total
petroleum hydrocarbons (TPH) and chemical oxygen demand (COD) from Al-Daura refinery wastewater. The system operated in semi-batch, thus, new wastewater was weekly added to the plant for 42 days. The results showed high removal percentages (98%) of TPH and (62.3%) for COD. Additionally, Phragmites australis biomass increased significant
The pollution producing from textile industries effluents is growing since the years, due to at discharged lots of it in water without treatment. The resulting effluent is colourful, highly toxic, and poses a significant environmental hazard. This problem can be solved by using enzymic biological treatment, where the Congo red dye was used with concentrations (100,200,300,500) mg /L, pH values (3,4,5,6,7,8), and variable temperatures (25,35,45)°C, the best removal of Congo red (CR) dye under optimum conditions for degradation was at concentration of 100 mg/L, at (pH 6, 25 °C) with efficiency of 99.85 % using the peroxidase enzyme extracted from red radish plant, while the removal percentage decreased when increase dye concentration
... Show More