The possibility of using zero-valent iron as permeable reactive barrier in removing lead from a contaminated groundwater was investigated. In the batch tests, the effects of many parameters such as contact time between adsorbate and adsorbent (0-240 min), initial pH of the solution (4-8), sorbent dosage (1-12 g/100 mL), initial metal concentration (50-250 mg/L), and agitation speed
(0-250 rpm) were studied. The results proved that the best values of these parameters achieve the maximum removal efficiency of Pb+2 (=97%) were 2 hr, 5, 5 g/100 mL, 50 mg/L and 200 rpm respectively. The sorption data of Pb+2 ions on the zero-valent iron have been performed well by Langmuir isotherm model in compared with Freundlich model under the studied conditions. Finite difference method and computer solutions (COMSOL) multiphysics 3.5a software based on finite element method were used to simulate the one-dimensional equilibrium transport of lead through sand aquifer with and without presence of barrier. The predicted and experimental results proved that the reactive barrier plays a potential role in the restriction of the contaminant plume migration and a reasonable agreement between these results was recognized.
Electromyogram (EMG)-based Pattern Recognition (PR) systems for upper-limb prosthesis control provide promising ways to enable an intuitive control of the prostheses with multiple degrees of freedom and fast reaction times. However, the lack of robustness of the PR systems may limit their usability. In this paper, a novel adaptive time windowing framework is proposed to enhance the performance of the PR systems by focusing on their windowing and classification steps. The proposed framework estimates the output probabilities of each class and outputs a movement only if a decision with a probability above a certain threshold is achieved. Otherwise (i.e., all probability values are below the threshold), the window size of the EMG signa
... Show MoreThe equation of Kepler is used to solve different problems associated with celestial mechanics and the dynamics of the orbit. It is an exact explanation for the movement of any two bodies in space under the effect of gravity. This equation represents the body in space in terms of polar coordinates; thus, it can also specify the time required for the body to complete its period along the orbit around another body. This paper is a review for previously published papers related to solve Kepler’s equation and eccentric anomaly. It aims to collect and assess changed iterative initial values for eccentric anomaly for forty previous years. Those initial values are tested to select the finest one based on the number of iterations, as well as the
... Show MoreTo finalize any construction investment project, it would be necessary to identify the most significant problems and obstacles that lead to project reluctance and stalling. Unexpected events and conflicts may have disrupted these strategies and impacted project development. Due to the high initial investment costs of construction projects, crises can have an immediate impact, resulting in significant financial losses. The 2014 financial crisis was one of the most prominent crises that Iraq faced, which prompted the researcher to identify and evaluate those obstacles through this research and questionnaires using Pareto scientific theory to exclude factors that do not contribute to project lag. It was discovered that 28 o
... Show MoreThe study of economic growth indicators is of fundamental importance in estimating the effectiveness of economic development plans, as well as the great role it plays in determining appropriate economic policies in order to optimally use the factors that lead to the dynamics of growth in Iraq, especially during a certain period of time. The gross domestic product (GDP) at current prices), which is considered a part of the national accounts, which is considered as an integrated dynamic of statistics that produces in front of policy makers the possibility of determining whether the economy is witnessing a state of expansion or evaluating economic activity and its efficiency in order to reach the size of the overall economy. The research aims
... Show MoreBackground: Mondor's disease means superficial thrombophlibitis of the chest wall in human, treatment is entirely symptomatic. Hot, wet dressing and anodynes may be used for pain relief.
Objective: To evaluate the role of systemic and transdermal action of diclofenac (olfen) with respect to the symptom and sign (pain, erythema along the superficial vein), and the use of Doppler ultrasonography which is a colored ultrasound used for assessment of flow of blood in vessels.
Method: The study was performed on 12 cases with Mondor's disease in middle age female patients with the involvement of lnframammary veins in all of the them (commonly affected), 4 cases had reassurance only, 4 cases had reassurance with systemic diclofenac, and th
Tobacco products of all kinds are harmful to public health, so legislation has paid great attention to regulating the process of tobacco production and distribution, whether at the level of national or international legislation, in a way that achieves legal protection for these products, so the establishment of civil liability for tobacco companies as a result of harm to the smoker The positive and the negative provoked a jurisprudential dispute due to the specificity of the work of these companies, and the jurisprudence differed in the legal nature of tobacco companies ’liability between contractual and tort liability in a way that enables the injured smoker to obtain his right to compensation.
Abstract
Friction stir welding is a relatively new joining process, which involves the joining of metals without fusion or filler materials. In this study, the effect of welding parameters on the mechanical properties of aluminum alloys AA2024-T351 joints produced by FSW was investigated.
Different ranges of welding parameters, as input factors, such as welding speed (6 - 34 mm/min) and rotational speed (725 - 1235 rpm) were used to obtain their influences on the main responses, in terms of elongation, tensile strength, and maximum bending force. Experimental measurements of main responses were taken and analyzed using DESIGN EXPERT 8 experimental design software which was used to develop t
... Show More