Experimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using water mist system. Also the results show a reduction range of 1.3 to 18.8℃ in the wall outside surface temperature. Finally numerical simulation with ANSYS-FLUENT.14 was conducted to compare its results with the experimental results of the roof and wall tests.
Abstract
Prescribing drugs to patients to treat ailments or reducing their morbidity may not be enough, even if the drugs were all indicated and in the right dose. Clinical pharmacists play a pivotal role in conducting information and instruction to patients and conveying feedback to treating physician when appropriate, and the final goal is in the interest of the patient. Identification and classification of drug related problems and discussing them with the health care providers. Prospective, interventional, clinical study for 180 hemodialysis patients, and was designed as two phases, an observational phase to identify drug related problems and classifying them according to the latest Pharmaceutical
... Show MoreThe study aimed to survey mushroom species from fields among herbs, palm trunks, and trees in central Iraq and to identify them on the basis of morphological and molecular characteristics. As a molecular identification result with polymerase chain reaction six species were recorded (with eight isolates): Agaricus bitorquis (Quéllt) Saccardo. 1887 (SHA14); Candolleomyces candolleanus (Fr.) D. Wächter & Melzer, 2020 (SHA15); Cyclocybe cylindracea (D.C.) Vizzini & Angelini, 2014 (SHA13); Leucoagaricus hesperius Vellinga, 2010 (SHA16); Volvariella sp. (SHA17), and Volvopluteus gloiocephalus (D. C.) Vizzini, Contu & Justo, 2011 (SHA10, SHA101 and SHA12), belonging to four families of Basidiomycetes: Agaricaceae, Pluteaceae,
... Show MoreThe aim of the research is a techno-economic analysis of the use of concentrated solar energy technologies in the Iraqi city, considering the concentrated solar energy technology is a renewable energy technology that derives its resources from the sun and is replenished at a rate that exceeds its use. It is also inexhaustible and environmentally friendly energy from its environmental footprint, unlike traditional fossil energy which produces greenhouse gases and a major cause of global warming.
This research measures the costs of concentrated solar energy technology to Reduce the effects caused by other energies and work to fill part of the shortfall in the total electricity production, even at a specific percentage, in preparati
... Show More