In this work, the adsorption of reactive yellow dye (Remazol yellow FG dye) by granular activated carbon (GAC) was investigated using batch and continuous process. The batch process involved determination the equilibrium isotherm curve either favorable or unfavorable by estimation relation between adsorption capacity and concentration of dye at different dosage of activated carbon. The results were fitted with equilibrium isotherm models Langmuir and Freundlich models with R2value (>0.97). Batch Kinetic study showed good fitting with pseudo second order model with R2 (0.987) at contact time 5 h. which provesthat the adsorption is chemisorptions nature. Continuous study was done by fixed bed column where breakthrough time was increased at flow rates
(21.67, 12.5 and 6 ml/min) and initial dye concentration (80, 40, 20 and 10 mg/l) were decreased and bed depth was increased (5, 10, 15 and 20 cm). The adsorption data were fitted to the fixed-bed adsorption mathematical models Thomas and Yoon- Nelson models. The results fitted well to the Thomas and Yoon-Nelson models with correlation coefficient, R2≥ 0.944. Average relative error ARE% was applied to examine the theoretical and experimental results.
To compare the corneal epithelial thickness profile in patients with dry eyes and keratoconus suspect with normal healthy eyes.
The study involved 120 eyes with an age range from 19 to 30 years. Forty eyes had normal corneal topography and no dry eyes. Forty eyes had dry eyes but had normal corneal topography. The last 40 eyes were keratoconus suspect and had no symptoms or signs of dry eyes.
Central epithelial thickness was not different statistically for all eyes. ( p-value: 0.1). The superior epithelial thickness was 53.5 µm ±3.1 in the control
Reclaimed (recycled) asphalt pavement (RAP), the most recycled material worldwide, is the mostly reclaimed material utilized in hot mix asphalt. Polymer (Crumb rubber) incorporation frequently leads to enhanced durability and resistance to heat cracking and rutting, two forms of permanent deformation. It also relieves stiffness and minimizes fatigue damage. This study aims to gather all previous RAP-related research and crumb rubber CR, so that the impact of using these materials on mechanical, physical properties of asphalt pavement, environmental effect and cost effective are clarify and explained. The finding of this research proved that the use of RAP and CR provide considerable structural and financial enhancements to the const
... Show MoreBy unusual method for separating two isomers of a substituted nitro-coumarin using a soxhlet extractor and in controlling temperature to get a selective nitration reaction, several new Schiff base coumarins were synthesized from nitro coumarins as starting material, which were reduced by Fe in glacial acetic acid to produce corresponding amino coumarin derivatives. Then the latter was reacted with different aromatic aldehydes to produce the desired Schiff bases derivatives. After characterization by Fourier transform infrared (FT-IR), Proton nuclear magnetic resonance (1HNMR) and Carbon-13 nuclear magnetic resonance (C-NMR), all these compounds were evaluated as potential Antimicrobial and Antioxidant Agents.
In order to promote sustainable steel-concrete composite structures, special shear connectors that can facilitate deconstruction are needed. A lockbolt demountable shear connector (LB-DSC), including a grout-filled steel tube embedded in the concrete slab and fastened to a geometrically compatible partial-thread bolt, which is bolted on the steel section's top flange of a composite beam, was proposed. The main drawback of previous similar demountable bolts is the sudden slip of the bolt inside its hole. This bolt has a locked conical seat lug that is secured inside a predrilled compatible counter-sunk hole in the steel section's flange to provide a non-slip bolt-flange connection. Deconstruction is achieved by demounting the tube from the t
... Show MoreIn the present work, the thermo-fluid characteristics of a heat exchanger formed of helical coiled tubes immersed in cold water are investigated experimentally. Two types of helical coiled tube are tested, a conventional vertical single helical coiled tube and a new triple vertical helical coiled tube in parallel connection called as meshed coils. The effect of hot water flow rates inside the tubes (ranges from 2.67 to 7.08 l/min), and its inlet temperatures (namely 50, 60, 70 and 80 °C) are investigated. The experimental results show that increasing the flow rate inside the meshed coils leads to decrease the temperature difference between inlet and outlet. An enhancement of heat transfer for meshed coils compared to single coil has been n
... Show MoreThirty swabes of medical implants were collected from Al-Yarmouk's hospital which were cultured on manitole agar to isolate Staphelococcus aureus . Only four samples gave positive results with this media. It was used ten types of antibiotics to test the sensitivity of this bacterium against them. All isolates of S. aureus were recorded as multidrug resistant and were considered as MRSA. One pledge alternative therapy is the utilize of certain pure bacterocin MIC (32.5 to 62.5 μg/ml) and it was compared with vancomycin (200-400 μg/ml) with average of (8 – 15) mm diameter of inhibition zones recpectively. The first reduction of biofilm formation ability has been proved in catheters when treatedby pure bacterocin. The test shows the highes
... Show More