In this study, pebble bed as an absorber and storage material was placed in a south facing, flat plate air-type solar collector at fixed tilt angle of (45°). The effect of this material and differ- ent parameters on collector efficiency has been investigated experimentally and
theoretically. Two operation modes were employed to study the performance of the solar air heater. An inte- grated mode of continuous operation of the system during the period of (11:00 am – 3:00 pm) and non-integrated mode in which the system stored the solar energy through the day then used the stored energy during the period of (3:00 pm – 8:00 pm). The results of parametric study in case of continuous operating showed that the maximum average temperature difference of air between inlet and outlet sections observed on (0.018 kg/s) air mass flow rate were exceeded (17°C) and the maximum outlet temperature that got was exceeded (34°C) for the three months (December, January and February) of experiments. Average efficiency was ranged from 53% to 65%. In the case of storage and then operating, the maximum outlet air temperature was ranged from (27°C) up to (31°C) then
decreased with spend of energy to reach (13°C) to (18°C) and the maximum storage energy was (165.14 W) for the porosity of (0.29) , height of (20 cm) and (0.01 kg/s) mass flow rate. The results also, showed that the solar air collector supplied a solar heating fraction (SHF) with an average of (0.65) for a meeting room (3 * 4 * 7 m) located in Baghdad as a case study.
In this paper, nanofluid of TiO2/water of concentrations of 0.002% and 0.004% volume was used. This nanofluid was flowing through heat exchanger of shell and concentric double tubes with counter current flow to the hot oil. The thermal conductivity of nanofluid is enhanced with increasing concentrations of the TiO2, this increment was by 19% and 16.5% for 0.004% and 0.002% volume respectively relative to the base fluid (water). Also the heat transfer coefficient of the nanofluid is increased as Reynold's number and nanofluid concentrations increased too. The heat transfer coefficient is increased by 66% and 49% for 0.004% and 0.002% volume respectively relative to the base fluid. This study showed that the friction
... Show MoreBackground: Chief complaint of patients attending dental clinic represents the first step towards treatment plan. However, most of patients are not aware but the extent and severity of periodontal disease, which could be also, misdiagnose by the dentist. Aim of the study: To investigate whether reported chief complaint(s) are consistent with oral hygiene status Materials and methods: Records of 1102 patients, attending periodontics clinics in the college of dentistry/ university of Baghdad, were used to determine ten most commonly reported chief complaints. Sample of patients was further subdivided according to gender and age. In addition, plaque and gingival index were recorded to determine oral hygiene status. Results: Patients mostly
... Show MoreBackground. The motor response is a fundamental ability that is evident during any physical or motor activity. However, the need for this ability varies from one sport to another and depends on the specific skills required in each sport. Objectives. This study aims to compare the average motor reaction times of the arm and leg among handball, basketball, and volleyball players aged 14 to 16 years. Methods. The sample included 30 players aged 14-16 years from the sports talent care center, evenly distributed on handball, basketball, and volleyball. Standardized tests were used to measure the speed of motor response, including the Batak Micro test for hands, which records the number of responses to light stimuli in 30 seconds, and the Saqer t
... Show MoreBackground: Repeated teenage pregnancy is a major burden on the healthcare system worldwide. Objective: We aimed to compare teenagers with their first and third pregnancies and to evaluate the likelihood of neonatal complications. Materials and Methods: This cross-sectional study was performed on female teenagers (aged ≤ 19 yr) with singleton pregnancies. The subjects (n = 298) were screened over 12 months. Ninety-six women were excluded, based on the exclusion criteria. The remaining subjects (n = 202) were divided into two groups: teenagers with first pregnancy (n = 96) and teenagers with third pregnancy (n = 47). The subjects were observed throughout pregnancy and delivery. The final sample size of the first and thi
... Show More An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct
The present work investigates the effect of magneto – hydrodynamic (MHD) laminar natural convection flow on a vertical cylinder in presence of heat generation and radiation. The governing equations which used are Continuity, Momentum and Energy equations. These equations are transformed to dimensionless equations using Vorticity-Stream Function method and the resulting nonlinear system
of partial differential equations are then solved numerically using finite difference approximation. A thermal boundary condition of a constant wall temperature is considered. A computer program (Fortran 90) was built to calculate the rate of heat transfer in terms of local Nusselt number, total mean Nusselt number, velocity distribution as well as te
Nanofluids are proven to be efficient agents for wettability alteration in subsurface applications including enhanced oil recovery (EOR). Nanofluids can also be used for CO2-storage applications where the CO2-wet rocks can be rendered strongly water-wet, however no attention has been given to this aspect in the past. Thus in this work we presents contact angle (θ) measurements for CO2/brine/calcite system as function of pressure (0.1 MPa, 5 MPa, 10 MPa, 15 MPa, and 20 MPa), temperature (23 °C, 50 °C and 70 °C), and salinity (0, 5, 10, 15, and 20% NaCl) before and after nano-treatment to address the wettability alteration efficiency. Moreover, the effect of treatment pressure and temperature, treatment fluid concentration (SiO2 wt%) and
... Show MorePhase-change materials (PCMs) have a remarkable potential for use as efficient energy storage means. However, their poor response rates during energy storage and retrieval modes require the use of heat transfer enhancers to combat these limitations. This research marks the first attempt to explore the potential of dimple-shaped fins for the enhancement of PCM thermal response in a shell-and-tube casing. Fin arrays with different dimensions and diverse distribution patterns were designed and studied to assess the effect of modifying the fin geometric parameters and distribution patterns in various spatial zones of the physical domain. The results indicate that increasing the number of