The need for participants’ performance assessments in academia and industry has been a growing concern. It has attendance, among other metrics, is a key factor in engendering a holistic approach to decision-making. For institutions or organizations where managing people is an important yet challenging task, attendance tracking and management could be employed to improve this seemingly time-consuming process while keeping an accurate attendance record. The manual/quasi-analog approach of taking attendance in some institutions could be unreliable and inefficient, leading to inaccurate computation of attendance rates and data loss. This work, therefore, proposes a system that employs embedded technology and a biometric/ web-based application to enhance attendance management. The hardware encompasses the integration of an ESP8266 NodeMCU and the biometric AS608 fingerprint sensor interfaced with the database for which the front-end and back-end integration was through the React framework. The system uses a web application that displays the attendance results and scheduled course data from its database, provides feedback to lecturers on which student missed classes and calculates a student’s average attendance for the semester. By implementing this system, the accuracy of student attendance is expected to experience an appreciable improvement, eliminate proxy signing, provide a more secure alternative for attendance recording, curtail tardiness to classes, and ultimately improve student productivity on execution.
The primary aim of this study was to identify the effect of using the simultaneous electronic presentations strategy in teaching basic skills of basketball to second-grade intermediate students. The present study had a parallel group, pre-post experimental design. In the present study the students of the Salah al-Din Intermediate School for the academic year 2020-2021 constituted the research community. A total of 75 students were present in the research community. Out of 75 students 16 students were selected as the participants for the study. The students falling within the age group of 13-14 years were recruited as the study participants, making up a percentage of 21.33 of the total number. Based on the results of th
... Show MoreThe internal observing system is considered a cornerstone for the high management in all the systems. It aims at defending the things for waste and increasing efficient and application the rules and regulations and constrictions. To easier for the high management activity in the internal observing system which in presented and practiced and to what extent can depend on it. Thus it goes to evaluate the internal observing system periodically to check the weak points in that system so as the find out the mistake, in the construction of the system or mistake, by indication of the workers. The importance of this study is represented in the need of increasing the coactivity in the internal observing system so as to be in touch with the new tre
... Show MorePushover analysis is an efficient method for the seismic evaluation of buildings under severe earthquakes. This paper aims to develop and verify the pushover analysis methodology for reinforced concrete frames. This technique depends on a nonlinear representation of the structure by using SAP2000 software. The properties of plastic hinges will be defined by generating the moment-curvature analysis for all the frame sections (beams and columns). The verification of the technique above was compared with the previous study for two-dimensional frames (4-and 7-story frames). The former study leaned on automatic identification of positive and negative moments, where the concrete sections and steel reinforcement quantities the
... Show MoreThe research work present a sensitive, accurate and fast developed for the determination of oxonium ion (HCl, H2SO4 , HClO4 and tartaric acid). It relies on the formation free iodine molecule from the I--IO3--H3O+ reaction which react with fluorescein sodium salt solution causing to quench the fluorescence light (continuous fluorescence) when irradiated by laser source at 405nm. Optimum parameters were studied giving to specify the chemical and physical parameters. Two line manifold was used. The flow rate of 1.3 and 1.5 mL/min was used, 35μL sample volume no.1 and sample volume no.2 , linear dynamic range extend from 0.05-7, 0.05-7, 0.1-10 and 0.1-10 mMol.l-1 with correlation coefficient of 0.9933, 0.9964, 0.9984 and 0.9973 for HCl, H2
... Show MoreThe possibility of predicting the mass transfer controlled CaCO3 scale removal rate has been investigated.
Experiments were carried out using chelating agents as a cleaning solution at different time and Reynolds’s number. The results of CaCO3 scale removal or (mass transfer rate) (as it is the controlling process) are compared with proposed model of prandtl’s and Taylor particularly based on the concept of analogy among momentum and mass transfer.
Correlation for the variation of Sherwood number ( or mass transfer rate ) with Reynolds’s number have been obtained .