Excessive intake of fluoride, mainly through drinking water is a serious health hazard affecting humans worldwide. In this study, the defluoridation capacities of locally available raw waste beef bones have been estimated. Several experimental parameters including contact time, pH, bone dose, fluoride initial concentration, bone grains size, agitation rate, and the effect of co-existence of anions in actual samples of wastewater were studied for fluoride removal from aqueous solutions. Results indicated excellent fluoride removal effeciency up to 99.7% at fluoride initial concentration of 10 mg F/L and 120 min contact time. Maximum fluoride uptake was obtained at neutral pH range 6-7. Fluoride removal kinetic was well described by the pseudo-second order kinetic model. Both, Langmuir and Freundlich isotherm models could fit the experimental data well with correlation coefficient values > 0.99 suggesting favorable conditions of the process. Furthermore, it was found that the co-existing anions had no significant effect on fluoride removal. Ion exchange and fluoride precipitation are the modes of fluoride removal.
Water quality sensors have recently received a lot of attention due to their impact on human health. Due to their distinct features, environmental sensors are based on carbon quantum dots (CQDs). In this study, CQDs were prepared using the electro-chemical method, where the structural and optical properties were studied. These quantum dots were used in the environmental sensor application after mixing them with three different materials: CQDs, Alq3 polymer and CQDs and Alq3 solutions using two different methods: drop casting and spin coating, and depositing them on silicon. The sensitivity of the water pollutants was studied for each case of the prepared samples after measuring the change in resistance of the samples at a temperature of
... Show MoreVisualization of water flow around different bluff bodies at different Reynolds number ranging (1505 - 2492) was realized by designing and building a test rig which contains an open channel capable to ensure water velocity range (4-8cm/s) in this channel. Hydrogen bubbles generated from the ionized water using DC power supply are visualized by a light source and photographed by a digital camera. Flow pattern around a circular disk of (3.6cm) diameter and (3mm) thickness, a sphere of (3.8cm) diameter and a cylinder of
(3.2cm) diameter and (10cm) length are studied qualitatively. Parameters of the vortex ring generated in the wake region of the disk and the separation angle of water stream lines from the surface of the sphere are plott
The adsorption of cephalexin.H2O from aqueous solution on attapulgite, bentonite and kaolin has been studied at the human body temperature (37.5ËšC) and at 5, 27, 47ËšC in 0.1M hydrochloric acid (pH 1.2). The value of pH 1.2 has been chosen to simulate the pH of stomach fluid. The clays show the following order: Bentonite > attapulgite > kaolin, for their activity to adsorb cephalexin.H2O. The charged clay particles can attract molecules either by electrostatic forces, for the molecules of oppositely charged, or by inducing dipole formation in the neutral molecule. The L-shaped adsorption isotherm indicated that drug molecules arrangement in a flat geometry on the clay surface. The
... Show MoreA mineralogical study using X-ray diffraction supported by scanning electron microscopic examination on the Paleocene- Eocene Kolosh and Gercus formations from northern Iraq is conducted to show the distribution of clay minerals and their paleoenvironmental implications. Smectite palygorskite, kaolinite, illite, and chlorite are commonly present in varying proportions within the Kolosh and Gercus formations. Association of smectite and chlorite in the claystone of the Paleocene Kolosh Formation refers to marine environment of this formation, whereas development of palygorskite fibers from smectite precursor may relate to post-depositional diagenesis. In addition, the abundance of illite and kaolinite in the Eocen
... Show MoreThe study has used Geographic Information Systems (GIS) data and Arc GIS software, to produce a new map. This map contains a spatial database of the newly constructed buildings, in the area of water resources engineering college, and using the above tool for updating contains the college in any time, also the map and browse all buildings individually or in clustered, for example, browsing geometric data, statistical data and the plans of drawings, and make any necessary changes to these sectors immediately, or in the future, like the expansion of the study halls by constructed a new floor, or add supplements, prepare any electrical to any building, and anything else. The paper also, updates the old Google Earth image, f
... Show MoreDifferent formula of bioagents (Rhizobium cicceri cp-93, Azospirillum sp.,
Pseudomonas fluorescence, Trichoderma harzianum ) used in this study as a
biofertilizer on wheat crop with two level of chemical fertilizer (0 and 12.5
kg/donm Dap) compared to 50kg/donm Dap (standard amount).the study carried out
in Iraq/Diyala –Alkhales during November 2014,results showed significant increase
in no. of spikes, no. of spikelet’s, length of spike ,Weight of 1000 seed and yield of
one m2 when adding (Rhizobium cicceri cp-93,Azospirillumsp+ Trichoderma
harzianum +12.5 kg/donm Dap) in comparison with the 50kg/donm Dap. Other
formulas recorded same results with the treatment 50kg/Donm Dap with not
significant differences
Iraqi crude Atmospheric residual fraction supplied from al-Dura refinery was treated to remove metals contaminants by solvent extraction method, with various hydrocarbon solvents and concentrations. The extraction method using three different type solvent (n-hexane, n-heptane, and light naphtha) were found to be effective for removal of oil-soluble metals from heavy atmospheric residual fraction. Different solvents with using three different hydrocarbon solvents (n-hexane, n-heptane, and light naphtha) .different variables were studied solvent/oil ratios (4/1, 8/1, 10/1, 12/1, and 15/1), different intervals of perceptual (15, 30-60, 90 and 120 min) and different temperature (30, 45, 60 and 90 °C) were used. The metals removal percent we
... Show More