This paper was aimed to study the efficiency of forward osmosis (FO) process as a new application for the treatment of wastewater from textile effluent and the factors affecting the performance of forward osmosis process.
The draw solutions used were magnesium chloride (MgCl2), and aluminum sulphate (Al2 ( SO4)3 .18 H2O), and the feed solutions used were reactive red, and disperse blue dyes.
Experimental work were includes operating the forward osmosis process using thin film composite (TFC) membrane as flat sheet for different draw solutions and feed solutions. The operating parameters studied were : draw solutions concentration (10 – 90 g/l), feed solutions concentration (5 – 30 mg/l), draw solutions flow rate (10 – 50 l/hr), feed solutions flow rate (20-60 l/hr), constant pressure and temperature were maintained at 0.5 bar and 30ºC respectively. And includes operating the forward osmosis process using cellulose triacetate (CTA) membrane as flat sheet for different draw solutions and feed solutions. The operating parameters studied were : draw solutions concentration (10 – 90 g/l), and feed solutions concentration (5 – 30 mg/l), constant temperature at 30ºC. It was found that water flux increases with increasing draw solution concentration, and feed solution flow rate and decreases with increasing draw solution flow rate and feed solution concentration for TFC and CTA. It was found MgCl2 given water flux larger than Alum. And also found that reactive red given water flux larger than disperse blue.
The experiments also show that CTA membrane gives higher water flux than TFC membrane for forward osmosis operation. The increase in water flux for CTA is about 12.85% than TFC.
Introduction: The use of screw-retained hybrid arch bars (HABs) is a relatively recent development in the treatment of mandibular fractures. The purpose of this study is to compare the clinical outcome between HAB and the conventional Erich arch bar (EAB) in the closed treatment of mandibular fractures. Materials and methods: This study included 18 patients who were treated for mandibular fractures with maxillomandibular fixation (MMF), patients were randomly assigned into a control group (n = 10) in which EAB was used and study group (n = 8) in which HAB was used. The outcome variables were time required for application and removal, gingival inflammation scores, postoperative complications, and incidence of wire-stick injury or gloves perf
... Show MoreFaujasite type NaY zeolite catalyst was prepared from locally available kaolin, then the prepared NaY zeolite have been modified by exchanging of sodium ion with ammonium to produce NH4Y zeolite. NH4Y zeolite was converted to HY zeolite by ion exchanging with oxalic acid. Zinc and nickel promoters have been added to the prepared HY zeolite catalyst, and the effect of these promoters on the catalytic activity of the prepared HY catalyst was studied in fluid catalytic cracking process using light gas oil as a feedstock. The experimental results show that the promoted catalyst gives higher gas oil conversion and gasoline yield than HY zeolite catalyst at the same reaction temperature and WHSV. It was also found that the promoted catalyst gi
... Show MoreTo investigate the research objectives, the researchers put the following hypothesis:
There was no statistically significant difference at the level of (0.05) between the average score of the students of the experimental group who studied the language of rhetoric according to model of learning method, and the average score of the students of the control group who studied the same article in the traditional way acquiring rhetorical concept. The researchers relied on the experimental design with the partial setting of the post-test, which depends on the experimental group that is taught using the model of the learning method, and the control group taught using the traditional method.
... Show MoreLowering specific energy consumption (SEC) in reverse osmosis (RO) plants is one of the most important criteria in water treatment industry. The present work focused on best suggested RO pilot plant configurations for minimizing specific energy consumption, finding the best configurations experimentally to recover the water with minimizing salts in permeate side in RO module, study the factors affecting the performance of single and two stage systems, TFC membrane is used in spiral wound module. Brackish water is used as feed solution with different concentrations (2000, 3000, 4000 and 5000 ppm). The operating parameters studied were permeate flux, rejection and SEC. The experimental results showed the permeate concentration increased and w
... Show MoreGundelia, a genus of flowering plants native to the Mediterranean region, particularly in Iraq, holds promise as a sustainable adsorbent for the treatment of dye-polluted water. This study explores the potential of Gundelia seeds (GS) waste as a biobased adsorbent for removing methylene blue dye from synthesized wastewater. Utilizing various analytical techniques, including scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, and X-ray diffraction analysis (XRD), we assessed GS as an active adsorbent with performance comparable to fabricated and expensive composites. Key parameters such as pH (3-11), pH at the point of zero charge, temperature (298-328 K), dose (0.02-0.1 g), dye concentration (10-50 ppm), and
... Show MoreIn this study, a new type of circulating three-phase fluidized bed reactor was conducted by adding a spiral path and was named as spiral three-phase fluidized bed reactor (TPFB-S) to investigate the possibility for removing engine oil (virgin and waste form) from synthetic wastewater by using Ricinus communis (RC) leaves natural and activated by KOH. The biosorption process was conducted by changing particle diameter in the range 150–300 and 300–600 µm, liquid flow rate in the range 2.5–4.5 L/min and gas flow rate in range of 0–1 L/min, while other parameters initial oil emulsion concentration, pH, adsorbent concentration, agitation speed and contact time were kept constant at 2000 mg/L, 2,
Purpose Heavy metals are toxic pollutants released into the environment as a result of different industrial activities. Biosorption of heavy metals from aqueous solutions is a new technology for the treatment of industrial wastewater. The aim of the present research is to highlight the basic biosorption theory to heavy metal removal. Materials and methods Heterogeneous cultures mostly dried anaerobic bacteria, yeast (fungi), and protozoa were used as low-cost material to remove metallic cations Pb(II), Cr(III), and Cd(II) from synthetic wastewater. Competitive biosorption of these metals was studied. Results The main biosorption mechanisms were complexation and physical adsorption onto natural active functional groups. It is observed that
... Show MoreMicrobiological contamination by fungi impacts the quality and safety of wheat grain storage. This study aimed to evaluate the efficacy of cold plasma in restricting the growth of the fungus, Aspergillus niger, which was isolated from wheat grains. A dielectric barrier discharge (DBD) operating at atmospheric pressure generated cold plasma that was used to treat the fungus, and the impact of this treatment was investigated at various periods 1, 2, 4, 6, and 15 minutes. The results revealed a highly significant decrease in the growth and number of spores of Aspergillus niger compared to the controls. This study revealed an efficient technique for enhancing wheat grain storage that could be a foundation for further large-scale studies.
... Show MoreThe disposal of textile effluents to the surface water bodies represents the critical issue especially these effluents can have negative impacts on such bodies due to the presence of dyes in their composition. Biological remediation methods like constructed wetlands are more cost-effective and environmental friendly technique in comparison with traditional methods. The ability of vertical subsurface flow constructed wetlands units for treating of simulated wastewater polluted with Congo red dye has been studied in this work. The units were packed with waterworks sludge bed that either be unplanted or planted with Phragmites australis and Typha domingensis. The efficacy of present units was evaluated by monitoring of DO, Temperature, COD
... Show More
