Preferred Language
Articles
/
joe-233
Aerobic biodegradation of phenol by Immobilized Pseudomonas sp. cells in two different bio-carrier matrices
...Show More Authors

Biotreatment using immobilized cells (IC) technology has proved to be the most promising and most economical approach for the removal of many toxic organic pollutants found in petroleum-refinery wastewater (PRW) such as phenol. This study was undertaken to evaluate the degradation of phenol by Pseudomonas cells individually immobilized in two different bio-carrier matrices including polyvinyl alcohol-guar gum (PVA-GG) and polyvinyl alcohol-agar agar (PVA-AA). Results of batch experiments revealed that complete removal of phenol was attained in the first cycle after 150 min using immobilized cells (IC) in both PVA-GG and PVA-AA. Additional cycles were confirmed to evaluate the validity of recycling beads of immobilized cells for phenol biodegradation. Results revealed that the phenol percentage removals were 95, 92, 86, and 84 % for second, third, fourth, and fifth cycles, respectively using Pseudomonas immobilized in PVA-GG beads. Whereby they were 96, 92, 90, and 84 % using Pseudomonas immobilized in PVA-AA beads for the same sequence of cycles.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Medicine And Life
Potential anti-obesity effects of two-graded doses of Iraqi <i>Hibiscus tiliaceus</i> leaves extract, alone and in combination with orlistat, on high-fat diet-induced obesity in male rats
...Show More Authors

View Publication
Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Gingival Marginal Leakage of Different Tooth Colored Materials Combination as an Intermediate Layer in Class II Composite Restoration (A Comparative In Vitro Study)
...Show More Authors

Background: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 30 2021
Journal Name
College Of Islamic Sciences
Contradiction oppositon al ruwia and al fatwa and his impact in different jurists in personal status and transactions and adomment
...Show More Authors

المقدمة

 الحمد لله رب العالمين، وأفضل السلام وأتم التسليم على سيدنا محمد، وعلى آله وصحبه، أجمعين، وعلى من تبعهم بإحسان إلى يوم الدين، أما بعد.

 فإن مسألة التعارض بين الرواية، والفتوى، من المسائل المشهورة عند الأصوليين والفقهاء،وهي من مباحث السنة عند الأصوليين، والتي تبنى عليها مسائل متعددة، وهي من أسباب اختلاف الفقهاء، فإذا ما روى أحد الرواة حديثاً معيناً، ثم عمل بخلاف ما روى، فللعل

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 24 2018
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
RECORDING OF TWO SPECIES OF THE GENUS DIPARTIELLA (RAABE, 1959) STEIN, 1961 (CLIOPHORA: TRICHODINIDAE) FOR THE FIRST TIME IN IRAQ FROM GILLS OF THE COMMON CARP CYPRINUS CARPIO
...Show More Authors

    The examination of gills of the common carp Cyprinus carpio revealed the presence of two species of the family Trichodinidae belonging to the genus Dipartiella (Raabe, 1959) Stein, 1961 namely D. indiana Saha and Bandyopadhyay, 2017 and D. kazubski Mitra and Bandyopadhyay, 2009 for the first time in Iraq from Al-Graiat location on the Tigris River at Baghdad city. This also represents the first record of the genus Dipartiella from fishes of Iraq. The descriptions and measurements of these two parasite species as well as their illustrations were given.

View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Relationship Study Between Total Length with Otolith Length and Thickness in Two Fish Species: Coptodon zillii (Gervais,1848) and Cyprinus carpio” (Linnaeus,1758)
...Show More Authors
Abstract<p>This study aimed new indications that may clarify the relationships between the total and standard lengths, and the length of the otolith, as well as the thickness and weight of these bones compared to the body weights of two different species of invasive fish in the Iraqi aquatic environment, the common carp <italic>Cyprinus carpio</italic> of the Cyprinidae family, and the common Tilapia. <italic>Coptodon zillii</italic>, from the Cichlidae family. The results showed that the otolith were not related to some of the vital characteristics of the studied fish, and there were differences in the correlation coefficient between some vital measurements with high signifi</p> ... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Influence of Different Fabrication and Impression Techniques on the Marginal Adaptation of Lithium Disilicate Crowns (A comparative in vitro study)
...Show More Authors

Background: The marginal adaptation has a key role in the success and longevity of the fixed dental restoration, which is affected by the impression and the fabrication techniques .The objective of this in vitro study was to evaluate and compare the marginal fitness of lithium disilicate crowns using two different digital impression techniques (direct and indirect techniques) and two different fabrication techniques (CAD/CAM and Press techniques). Materials and Methods: Thirty two sound upper first premolar teeth of comparable size extracted for orthodontic reason were selected in this study .Standardized preparation of all teeth samples were carried out with modified dental surveyor to receive all ceramic crown restoration with 1 mm deep

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Feb 21 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of different finishing and polishing systems on surface roughness of new low polymerized composite materials (An in vitro study)
...Show More Authors

Background: Prophylaxis methods are used to mechanically remove plaque and stain from tooth surfaces; such methods give rise to loss of superficial structure and roughen the surface of composites as a result of their abrasive action. This study was done to assess the effect of three polishing systems on surface texture of new anterior composites after storage in artificial saliva. Materials and methods: A total of 40 Giomer and Tetric®N-Ceram composite discs of 12 mm internal diameter and 3mm height were prepared using a specially designed cylindrical mold and were stored in artificial saliva for one month and then samples were divided into four groups according to surface treatment: Group A (control group):10 specimens received no surfa

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of Shear Bond Strength of Sapphire Bracket Bonded to Zirconium Surface after Using Different Surface Conditioning Methods (In Vitro Study)
...Show More Authors

Background: The present study was carried out to compare shear bond strength of sapphire bracket bonded to zirconium surface after using different methods of surface conditioning and assessment of the adhesive remnant index. Materials and methods: The sample composed of 40 zirconium specimens divided into four groups; the first group was the control, the second group was conditioned by sandblast with aluminum oxide particle 50 μm, the third and fourth group was treated by (Nd: YAG) laser (1064nm)(0.888 Watt for 5 seconds) for the 1st laser group and (0.444 Watt for 10 seconds) for the 2nd laser group. All samples were coated by z-prime plus primer. A central incisor sapphire bracket was bonded to all samples with light cure adhesive res

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Effect of Recirculation Ratio on the Uniformity Flow in a High Area Ratio of Outlets Pipe at Different Entrance flow rates
...Show More Authors

The uniform flow distrbiution in the multi-outlets pipe highly depends on the several parameters act togather. Therefor, there is no general method to achieve this goal. The  goal of this study is to investigate the proposed approach that can provide significant relief of the maldistribution. The method is based on re-circulating portion of flow from the end of the header to reduce pressure at this region . The physical model consists of main manifold with uniform longitudinal section having diameter of 152.4 mm (6 in), five laterals with diameter of 76.2 mm (3 in), and spacing of 300 mm. At first, The experiment is carried out with conventional manifold, which is a closed-end. Then, small amount of water is allowed

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2010
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of microleakage Restorative Dentistry Comparison of microleakage in three different retrograde cavity preparations with Mineral Trioxide Aggregate as filling material
...Show More Authors

Background: The apical seal is the single most important factor in determining the success of surgical endodontics, the aim of this study was to compare the sealing ability of Mineral Trioxide Aggregate in three different cavity designs. Materials and Methods: Thirty extracted human single-rooted teeth were divided into three groups of ten teeth per group, a retrograde cavity preparation was carried out using a low speed handpiece and round bur with parallel walls in the first group, ultrasonic retrotip and unit in the second group and a low speed handpiece with a carbide inverted cone bur with undercuts in the third group, all the cavities were filled with MTA. microleakage was measured by dye penetration technique using methylene blue. Re

... Show More
Preview PDF