Preferred Language
Articles
/
joe-2305
Compression of an ECG Signal Using Mixed Transforms
...Show More Authors

Electrocardiogram (ECG) is an important physiological signal for cardiac disease diagnosis. With the increasing use of modern electrocardiogram monitoring devices that generate vast amount of data requiring huge storage capacity. In order to decrease storage costs or make ECG signals suitable and ready for transmission through common communication channels, the ECG data
volume must be reduced. So an effective data compression method is required. This paper presents an efficient technique for the compression of ECG signals. In this technique, different transforms have been used to compress the ECG signals. At first, a 1-D ECG data was segmented and aligned to a 2-D data array, then 2-D mixed transform was implemented to compress the ECG data in the 2-
D form. The compression algorithms were implemented and tested using multiwavelet, wavelet and slantlet transforms to form the proposed method based on mixed transforms. Then vector quantization technique was employed to extract the mixed transform coefficients. Some selected records from MIT/BIH arrhythmia database were tested contrastively and the performance of the
proposed methods was analyzed and evaluated using MATLAB package. Simulation results showed that the proposed methods gave a high compression ratio (CR) for the ECG signals comparing with other available methods. For example, the compression of one record (record 100) yielded CR of 24.4 associated with percent root mean square difference (PRD) of 2.56% was achieved.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Apr 22 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An evaluation of an Iraqi phosphate-bonded investment and a commercial type on the marginal fit of ceramometalcopings using three different investing and burnout techniques
...Show More Authors

Background: The accuracy of fitness of any dental casting is imperative for the success of any prosthodontic treatment. From the time that dental casting was first introduced, efforts have been made to produce more accurate and better fitted castings with minimal marginal discrepancy. The aim of this in vitro study was to evaluate the effects of three different investing and burnout techniques on the vertical marginal discrepancies ofceramometalcopings invested with two types of phosphate- bonded investments. Materials and methods: Sixty wax patterns were fabricated on a standardized prepared brass die representing an upper central incisor by the aid of a custom-made split mold. Three different investing and burnout techniques were applied

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Physics: Conference Series
Mixed Ligand Complexes of Schiff Base and Nicotinamide: Synthesis, Characterization and Antimicrobial Activities
...Show More Authors

A new Schiff base of HL has been synthesized from amoxicillin drug and 4- Chlorobenzophenone. Cr (III), Fe (III), Co (II), Ni (II), Cu (II), Cd (II) and Hg (II) mixed ligands complexes of Schiff base and Nicotinamide. Diagnosis of synthesis ligand and its complexes are done by 1HNMR, 13CNMR and thermal analysis for HL ligand, FTIR, UV-visible, molar conductance, CHN analysis, magnetic susceptility and atomic absorption. Octahedral geometries have been suggested for all complexes. All compounds under study were tested antimicrobial activity against four type of bacteria such as Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus Bacillis subtilis in nutrient agar.

Preview PDF
Scopus (2)
Scopus
Publication Date
Mon Aug 03 2020
Journal Name
Digest Journal Of Nanomaterials And Biostructures
PREPARATION OF MIXED In2O3 – CdO THIN FILMS BY CSP TECHNIQUE FOR LIGHT SENSING
...Show More Authors

In this work, chemical spray pyrolysis deposition (CSP) technique was used to prepare a mixed In2O3-CdO thin films with different CdO content (10, 30 and 50)%volume ratio on glass substrates at 150 ᵒC substrate temperature. The surface morphology and structural properties were measured to find the optimum conditions to improve thin films properties for using as photo detector. Current –Time, the sensitivity and response speed vary for each mixture. Samples with 10% vol. CdO content has square pulse response with average rise time nearly 1s and fall time 1s.

Publication Date
Fri Sep 27 2019
Journal Name
Iop Conf. Series: Journal Of Physics: Conf. Series
Preparation and Spectroscopic Characterization of Chromium(III) and Iron(III) Mixed Ligand Complexes
...Show More Authors

.Curcumin (Cur) and L phenylalanine (Phy) compounds were used to prepare two mixed ligand complexes with Cr (III) and Fe (III) ions. The synthesized complexes are characterized by using conductivity measurement and different spectral methods like FT-IR and UV- Vis .Molar conductance and analytical studies confirmed that the complexes exhibit octahedral geometry., suggest that the complexes are formed in 1: 1 :2 [ L : Metal : 2phe ] ratio and they proposed to have the general formulae [M(Cur)(phe)2] Cl (M= Cr (III) and Fe (III) The compound dyeing method was studied and applied to acrylic fabric.The antibacterial activity of curcumin, phenylalanine and their mixed ligand complexes were examined on pathogenic bacterial strains and showed good

... Show More
Preview PDF
Publication Date
Thu Mar 01 2012
Journal Name
Journal Of Magnetism And Magnetic Materials
Structural analysis, magnetic and electrical properties of samarium substituted lithium–nickel mixed ferrites
...Show More Authors

View Publication
Scopus (136)
Crossref (130)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Recurrent Stroke Prediction using Machine Learning Algorithms with Clinical Public Datasets: An Empirical Performance Evaluation
...Show More Authors

Recurrent strokes can be devastating, often resulting in severe disability or death. However, nearly 90% of the causes of recurrent stroke are modifiable, which means recurrent strokes can be averted by controlling risk factors, which are mainly behavioral and metabolic in nature. Thus, it shows that from the previous works that recurrent stroke prediction model could help in minimizing the possibility of getting recurrent stroke. Previous works have shown promising results in predicting first-time stroke cases with machine learning approaches. However, there are limited works on recurrent stroke prediction using machine learning methods. Hence, this work is proposed to perform an empirical analysis and to investigate machine learning al

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Maximum Bite Force among Iraqi Primary School Children in Mixed dentition
...Show More Authors

View Publication
Crossref
Publication Date
Wed Aug 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectroscopic Studies of a New Mixed Ligand Complex of Fe(III) in Aqueous Medium
...Show More Authors

A spectrophotometric study of Fe(III) mixed ligand complex has been

performed  involving  1,4 phenylenediamine  (A) and  anthran i lic acid (B) ligand  at 25°C  and  aconstant  ionic strength  of  µ= 0.05M  NaC I04•  The optimum  pH was  found  to be pH=4.l. The format ion  rat io of the new complex   is   determined   to   be   2:1:4  of   Fe(III):(A):(B).   The   molar absorptivity was determined to be :::::: 0.5 x  I 04•  Stepwise spectrum change of the complex formation  is recorded by continuous flow system. Keywords: Mixed ligand

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Extension of the Chebyshev Method of Quassi-Linear Parabolic P.D.E.S With Mixed Boundary Conditions
...Show More Authors

The researcher [1-10] proposed a method for computing the numerical solution to quasi-linear parabolic p.d.e.s using a Chebyshev method. The purpose of this paper is to extend the method to problems with mixed boundary conditions. An error analysis for the linear problem is given and a global element Chebyshev method is described. A comparison of various chebyshev methods is made by applying them to two-point eigenproblems. It is shown by analysis and numerical examples that the approach used to derive the generalized Chebyshev method is comparable, in terms of the accuracy obtained, with existing Chebyshev methods.

View Publication Preview PDF
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Iraqi Journal Of Physics
Effect of Silver Nanoparticles on Fluorescence Intensity of Fluoreseina Dye Mixed in One Solution
...Show More Authors

Metal enhanced fluorescence (MEF) is an unequaled phenomenon of metal nanoparticle surface plasmons, when light interacts with the metal nanostructures (silver nanoparticles) which result electromagnetic fields to promote the sensitivity of fluorescence. This work endeavor to study the influence of silver nanoparticles on fluorescence intensity of Fluoreseina dye by employment mixture solution with different mixing ratio. Silver nanoparticles had been manufactured by the chemical reduction method so that Ag NP layer coating had been done by hot rotation liquid method. The optical properties of the prepared samples (mixture solution of Fluoreseina dye solutions and colloidal solution with 5 minutes prepared of Ag NPs) tested by using UV-V

... Show More
View Publication Preview PDF
Crossref