Preferred Language
Articles
/
joe-2294
Removal of Cu2+, Pb2+ , And Ni 2+ Ions From Simulated Waste Water By Ion Exchange Method On Zeolite And Purolite C105 Resin
...Show More Authors

The removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on purolite C105. The obtained sorption affinity sequence was Cu 2+> Ni2+> Pb2+ in both resins.
Langmuir isotherm expressions were found to give better fit to the experimental data compared to Freundlich and BET models. Kinetic data correlated well with Lagergren first order kinetic model, indicating the reversible reaction with an equilibrium being established between liquid and solid phase.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Desalination And Water Treatment
Biosorption of Cd(II) ions by Chlorella microalgae: isotherm, kinetics processes and biodiesel production
...Show More Authors

This study aims to remove Cd(II) ions from simulated wastewater by using Chlorophyceae algae (CA). Different parameters were studied to show their effects on the biosorption efficiency of CA. These parameters are: the effect of pH 3-7, initial metal ion concentration 20-200 mg/L, sorbent dos-age 0.05-2 g/L, contact time 5-180 min, and agitation speed 100-300 rpm. We found that both the Langmuir and Freundlich models appropriate for characterizing the metal removal process. The biosorption data fit best with the results of the pseudo-second-order kinetic model, demonstrating that the chemisorption process is the dominant mechanism controlling the removal. CA was char-acterized using the scanning electron microscopy test, prior to and post bi

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of The Iraqi University
Exclusion optimal portfolio from outlier by using fuzzy c-means clustering - analytical research at the Iraqi Stock Exchange
...Show More Authors

This research aims to solve the problem of selection using clustering algorithm, in this research optimal portfolio is formation using the single index model, and the real data are consisting from the stocks Iraqi Stock Exchange in the period 1/1/2007 to 31/12/2019. because the data series have missing values ,we used the two-stage missing value compensation method, the knowledge gap was inability the portfolio models to reduce The estimation error , inaccuracy of the cut-off rate and the Treynor ratio combine stocks into the portfolio that caused to decline in their performance, all these problems required employing clustering technic to data mining and regrouping it within clusters with similar characteristics to outperform the portfolio

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 25 2021
Journal Name
Iraqi Journal Of Science
Synthesis, Characterization and Kinetic Studies of Chelate Polymer Derived from 3-Nonyl Benzene and its Use for the Removal of Some Heavy Metals from Aqueous Solutions
...Show More Authors

    A new chelate polymer (2-5-hydroxy-3-methyl-2- (3-nonyl benzene) imino) methyl) benzyl) 4-6-dimethyphenol] (K4) was prepared by using the condensation reaction method and identified by several techniques, including FT-IR, NMR, and atomic absorption spectroscopy, as well as TG-DTA thermal analysis. The kinetic equilibrium for the sorption of lead and cadmium ions on the chelate polymer surface was also investigated. The results showed that the sorption of both ions followed the pseudo-first-order and pseudo-second-order kinetic equilibrium. The rate constant values of pseudo-first-order reaction  were equal to 0.062 and 0.057 min-1  , while the values of pseudo-second-order were 0.0103 and 0.053 L.m

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis
...Show More Authors

Abstract Background: One of the most important methods to replace lost teeth is dental implants. In order to increase the strength of connection of the implant with the jaw bone to provide early loading after placement, implant is coated by different coating materials that achieved that purpose. The aim of this study was to evaluate the influence of coating CP Ti implant with calcium carbonate on the strength of bone-implant interface after two and six weeks of implantation in rabbit femur bone by torque removal test, histological and histomorphometric analysis. Materials and methods: Coating the surface of commercially pure titanium screws with extra pure synthetic calcium carbonate via electrophoretic deposition method (EPD) was done. The

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
Reactive Adsorption Desulfurization by Nanocrystalline ZnO/Zeolite A Molecular Sieves
...Show More Authors

      Nanocrystalline ZnO/Zeolite type A composite was prepared by simple method of operation by . the precipitation of zinc oxide and loading on zeolite 5A in one step. Characterization was made by X-ray diffraction (XRD), X-ray fluorescence(XRF), N2  adsorption- desorption for BET surface area, and Atomic force microscopy (AFM). Results showed that zinc oxide was loaded on zeolite as noticed by the characteristic peaks and was of nano scale having an average diameter of 88.57nm. The percentage loading of ZnO on zeolite A was 28.37% and the surface area was 222m2/g. The activity of the prepared catalyst was examined in the desulfurization of double hydrogenated diesel fuel. The process was investigated in a

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Removal of Cadmium from Industrial Wastewater using Electrocoagulation Process
...Show More Authors

Cadmium is one of the heavy metal found in the wastewater of many industries. The electrocoagulation offers many advantages for the removal of cadmium over other methods. So the removal of cadmium from wastewater by using electrocoagulation was studied to investigate the effect of operating parameters on the removal efficiency. The studied parameters were the initial pH, initial concentration, and applied voltage. The study experiments were conducted in a batch reactor with  with two pairs of aluminum electrodes with dimension  and 2mm in thick with 1.5 cm space between them. The optimum removal was obtained at pH =7, initial concentration = 50 mg/L, and applied voltage = 20 V and it was 90%.

View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Plant Archives
The effect of adding some organic and mineral substances to calcareous soil on adsorption and desorption of copper and its removal efficiency from soil
...Show More Authors

Scopus (1)
Scopus
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Preparation Activated Carbon from Scrap Tires by Microwave Assisted KOH Activation for Removal Emulsified Oil
...Show More Authors

In this paper activated carbon adsorbents produced from waste tires by chemical activation methods and application of microwave assisted KOH activation. The influence of radiation time, radiation power, and impregnation ratio on the yield and oil removal which is one of the major environmental issues nowadays and considered persistent environmental contaminants and many of them are suspected of being carcinogenic. Based on Box-Wilson central composite design, polynomial models were developed to correlate the process variables to the two responses. From the analysis of variance the significant variables on each response were identified.  Optimum conditions of 4 min radiation time, 700 W radiation power and 0.5 g/g impregnation ratio

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Heliyon
Removal of copper by Azolla filiculoides and Lemna minor: phytoremediation potential, adsorption kinetics and isotherms
...Show More Authors

View Publication
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Wed Mar 28 2018
Journal Name
Iraqi Journal Of Science
Hypothetical Method for Gamma Dose Rate Assessment to Conditioned Radioactive waste Container
...Show More Authors

Metallic solid radioactive waste class low level - short lived Radioactive Waste

(LL-SL RW) is the main type of radioactive waste generated from decommissioning operations. Transport, storage and disposal regulations require for gamma emitting radioactive waste (mainly by 137Csisotope), that the dose rate in the proximity of the container should stand below a certain threshold. Also, the conditioning technique (using cementation technique) based on certain matrix with specific ratios should be able to attenuate the gamma radiation activity to the minimum level or to acceptable dosage rate at distance of 1m from the container. In this paper ,in absence of suitable labs for waste package assessment ,hypothetical method&n

... Show More
View Publication Preview PDF