Preferred Language
Articles
/
joe-2259
Boron Removal by Adsorption onto Different Oxides
...Show More Authors

A research was conducted to determine the feasibility of using adsorption process to remove boron from aqueous solutions using batch technique. Three adsorbent materials; magnesium, aluminum and iron oxide were investigated to find their abilities for boron removal. The effects of operational parameters on boron removal efficiency for each material were determined.
The experimental results revealed that maximum boron removal was achieved at pH 9.5 for magnesium oxide and 8 for aluminum and iron oxide. The percentage of boron adsorbed onto magnesium,aluminum and iron oxide reaches up to 90, 42.5 and 41.5% respectively under appropriate conditions. Boron concentration in effluent water after adsorption via magnesium oxide comply with the allowable
concentration according to WHO and the Iraqi drinking water guidelines, i.e. below 0.5 mg/l. Aluminum and iron oxide yield effluent water with boron concentration more than allowable limits. Accordingly,magnesium oxide is more suitable as adsorbent for boron removal from water; for its high adsorbent capacity and high removal ability for boron compared with aluminum and iron oxide.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The effect of mineral levels in the mother’s circulation on the outcome of pregnancy
...Show More Authors

Background: Dietary intakes are critical during pregnancy, because inadequate amounts of key nutrients may compromise fetal development or maternal health. In addition to that maternal diet could be one of the methods to select the gender of the baby. The aim of the study is to correlate the level of the minerals in the mother’s blood with the gender and wellbeing of the baby after delivery.Patients and Methods: Fifty women were involved in this study with a mean age (23.92 ± 4.75), collected from the labor room during labor in the period between December 2013 and May 2014, in Baghdad teaching hospital. After taking a full history from the women, 10 ml of blood was withdrawn from them, 2ml in EDTA tubes for lead estimation and 8 ml in pl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Processing Eruca sativa leaves in the nanoscale and study its effectiveness for removing Cibacron red dye from their aqueous solutions
...Show More Authors

    The discharge of dyes into the water is a significant source of pollution, which is especially concerning given that textile mills are the primary contributor. Nanomaterial-based solutions to this issue have required extensive research and investigation due to their complex nature. In this research, novel nanoparticle were successfully synthesized using the leaves of the Eruca sativa plant. The nano was analyzed using scanning and transmission electron microscopy (SEM and TEM) measurements, and their crystal structure was determined using the X-ray diffraction technique (XRD). The incorporation of NPs resulted in an increase in the uptake of the Cibacron red dye. At a contact time of 30 minutes, observed a faster adsor

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri May 06 2022
Journal Name
Razi Vaccine & Serum Research Institute
Effect of Betaine on Blood Parameters Related to the Iron Status in Acrylamide-Treated Rats
...Show More Authors

Archives of Razi Institute (ARI)

View Publication
Publication Date
Sun Dec 19 2021
Journal Name
Iraqi Journal Of Science
Prevalence of anemia and determination of some hematological parameters among pregnant women in Baghdad city
...Show More Authors

From 124 women in different stage of pregnancy ,there were 83 (67%) conceded
anemic and 41(33%) were non anemic ,there were 54(65%) suffering from iron
deficiency anemia. According to the form of anemia , 27 (32.5%) were suffering
from mild anemia, 41 (49.4%) moderately anemia while15 (18.1%) severe anemia
The number of anemic pregnant women from Baghdad was 39 (47%) and the
internally displaced anemic pregnant women 44 (53%). the anemic pregnant women
who were primigravida 36 (43.4%), while the pregnant women who were multipart
gravida 47 (56.6%) .The number of anemic pregnant women was 26(31.3%) for age
of 17-27y ,33(39.8%) for age of 28-37y and 24(28.9% )for age of 38-45y .while the
number of anemic pregnant

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Study of the mechanical properties of Iron-Epoxy composite materials
...Show More Authors

Iron-Epoxy composite samples were prepared by added
different weight percentages (0, 5, 10, 15, and 20 wt %) from Iron
particles in the range of (30-40μm) as a particle size. The contents
were mixed carefully, and placed a circular dies with a diameter of
2.5 cm. Different mechanical tests (Shore D Hardness, Tensile
strength, and Impact strength ) were carried out for all samples. The
samples were immersed in water for ten weeks, and after two weeks
the samples were take-out and drying to conducting all mechanical
tests were repeated for all samples. The hardness values increased
when the Iron particle concentration increased while the Impact
strength is not affected by the increasing of Iron particles
c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 16 2022
Journal Name
Iraqi Journal Of Science
The Variation in Levels of Some Male Pituitary and Gonadal Hormones in Beta-Thalassemia Major Patients in Iraq
...Show More Authors

This study was aimed to investigate the iron overload effect on the levels of ferritin, testosterone, follicle stimulating hormone (FSH), luteinizing hormone (LH) and prolactin (PRL) in male patients with β-thalassemia. Blood levels of sex hormones and ferritin were determined in (50 males) beta-thalassemia patients, aged (16-23) years and in (30) healthy males matched for age. They were recruited from the Abin Al-Balady Hospital in Baghdad. Ichroma™ kits were used to determine the blood levels of sex hormones and ferritin. The results showed that the level of testosterone, LH and FSH were significantly (p≤ 0.05) lower in β-thalassemia male patients compared to controls. Furthermore, the level of ferritin and prolactin in male pati

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Iron Deficiency Anemia: The Utility of Upper Gastrointestinal Endoscopy and Histopathology
...Show More Authors

Background: occult blood loss must be considered as a
possible cause in every case of iron deficiency anemia.
Objective: to evaluate upper gastrointestinal endoscopy
in finding a potential cause for iron deficiency anemia
among children in Al-Anbar governorate.
Methods: Twenty five children aged 2-14 years, referred
to the gastroenterology unit in Al-Ramadi General Hospital
for upper gastrointestinal endoscopy had iron deficiency
anemia. Fiberoptic endoscopy was used under general
anesthesia and endoscopic tissue biopsies were taken from
22 patients for histopathological examination.
Results: The main presenting signs and symptoms were
pallor, abdominal pain, and stunting. The upper
gastrointestinal

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Construction of New Ion Selective Electrodes for Determination Fe(III) and Their Application in Pharmaceutical samples
...Show More Authors

Liquid membrane electrodes for the determination iron(III) were constructed based on chloramphenicol sodium succinate and iron(III) CPSS-Fe(III) as ion pair complex, with four plasticizers Di-butyl phosphate (DBP); Di-butyl phthalate (DBPH); Di-octyl phthalate (DOP); Tri-butyl phosphate (TBP); in PVC matrix . These electrodes give Nernstian and sub-Nernstian slopes (19.79, 24.60, 16.01 and 13.82mV/decade) and linear ranges from (1x10-5-1x10-2 M, 1x10-5-1x10-2 M, 1x10-6-1x10-2 M and 1x10-5-1x10-2 M) respectively. The best electrode was based on DBP plasticizer which gave a slope 19.79 mV/decade, correlation coefficient 0.9999, detection limit of 9×10-6 M, lifetime 37 day displayed good stability and reproducibility and used to determine

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 28 2019
Journal Name
The Open Rheumatology Journal
The Value of Soluble Transferrin Receptor and Soluble Transferrin Receptor-ferritin Index in Discriminating Iron Deficiency Anaemia from Anaemia of Chronic Disease in Patients With Rheumatoid Arthritis
...Show More Authors
Background:

Anaemia is a common extra-articular manifestation of rheumatoid arthritis (RA) where anaemia of chronic disease (ACD) and iron deficiency anaemia (IDA) are the two most frequent types. The distinction between these two types of anaemia has always been challenging requiring sophisticated techniques. Serum transferrin receptor (sTfR) a truncated soluble form of the transferrin receptor is one of the parameters that is influenced by the Iron content and supply to the erythrons and is not affected by inflammatory status and therefore the use of the sTfR/log ferritin (sTfR-F) index can be a reliable indicator of functional iron deficiency.

Aim of the s
... Show More
View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Removing of Hexavalent Chromium from Aqueous Solutions Using Dried Yogurt, and Studying Isotherm, Kinetic and Thermodynamic Parameters
...Show More Authors

     In this study, Yogurt was dried and milled, then shaked with distilled water to remove the soluble materials, then again dried and milled. Batch experiments were carried out to remove hexavalent chromium from aqueous solutions. Different parameters were optimized such as amount of adsorbent, treatment time, pH and concentration of adsorbate. The concentrations of Cr6+ in solutions are determined by UV-Visible spectrophotometer.  Maximum percentage removal of Cr6+ was 82% at pH 2. Two equilibrium adsorption isotherms mechanisms are tested Langmuir and Freundlich, the results showed that the isotherm obeyed to Freundlich isotherm. Kinetic models were applied to the adsorption of Cr6+ ions on the adsorbents, ps

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref