Preferred Language
Articles
/
joe-2256
Effect of Design Parameters and Support Conditions on Natural Frequency of Pipe Excited by a Turbulent Internal Flow
...Show More Authors

In this study, the effect of design parameters such as pipe diameter, pipe wall thickness, pipe material and the effect of fluid velocity on the natural frequency of fluid-structure interaction in straight pipe conveying fully developed turbulent flow were investigate numerically,analytically and experimentally. Also the effect of support conditions, simply-simply and clamped-clamped was investigated. Experimentally, pipe vibrations were characterized by accelerometer mounted on the pipe wall. The natural frequencies of vibration were analyzed by using Fast Fourier Transformer (FFT). Five test sections of two different pipe diameters of 76.2
mm and 50.8 mm with two pipe thicknesses of 3.7 mm and 2.4 mm and two pipe materials,stainless steel and polyvinyl chloride PVC in the range of Reynolds numbers from 4*104 to 5*105 were studied. Mathematically, the governing continuity and momentum equations were solved numerically by using the finite volume method to compute the characteristics of two dimensional turbulent flow. The dynamics of a pipe conveying fluid was described by the Transfer Matrix Method (TMM) which is provides a numerical technique for solving the equations of pipe vibrations for simply-simply and clamped supports. The results showed that,the natural frequencies increase with pipe diameter increase and the natural frequencies slightly increases with pipe wall thickness increase. Also, the natural frequencies in clamped-clamped supported pipe are higher than those in simply-simply supported pipe.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Design and Implementation of Single-Phase Boost PFC Converter
...Show More Authors

In this paper, a single-phase boost type ac-dc converter with power factor correction (PFC) technique is designed and implemented. A current mode control at a constant switching frequency is used as a control strategy for PFC converter. The PFC converter is a single-stage singleswitch boost converter that uses a current shaping technique to reshape the non-sinusoidal input current drawn by the bulky capacitor in the conventional rectifier. This technique should provide an input current with almost free-harmonics, comply with the IEC61000-3-2 limits, and a system operates with near unity power factor. The other function of the boost converter that should be
accomplished is to provide a regulated DC output voltage. The complete designed

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 31 2019
Journal Name
Journal Of Engineering And Applied Sciences
Design and Implementation of Electronic Infrastructure for Academic Establishment
...Show More Authors

View Publication
Crossref
Publication Date
Tue Jan 05 2016
Journal Name
Diyala Journal Of Medicine
Correlations of morphological (macroscopic and microscopic) parameters of placenta with maternal age and parity
...Show More Authors

Background: Placenta is a chief cause of maternal and perinatal mortality and significant factor in fetal growth retardation. It undergoes different variations in weight, volume, structure, shape and function continuously throughout the gestation tosupport the prenatal life. Cautious examination of placenta can give information which can be useful in the management of complications in mother and the newborn. Objective: The present work has been attempted towards determination of the morphological ( macroscopic and microscopic) parameters of human full-term placentae and their relation with different parity and age group of mothers. Patients and Methods: A whole of 40 placentae were recently collected.They were divided into four groups

... Show More
Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Medicinal And Chemical Sciences
Echocardiographic Assessment of the Aortic Stenosis Valve Area: Parameters and Outcome
...Show More Authors

Background: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.

Scopus (10)
Scopus
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Separation of Bovine Serum Albumin Using Chromatographical Column: Parameters and Simulation
...Show More Authors

A liquid-solid chromatography of Bovine Serum Albumin (BSA) on (diethylaminoethyl-cellulose) DEAE-cellulose adsorbent is worked experimentally, to study the effect of changing the influent concentration of (0.125, 0.25, 0.5, and 1 mg/ml) at constant volumetric flow rate Q=1ml/min. And the effect of changing the volumetric flow rate (1, 3, 5, and 10 ml/min) at constant influent concentration of Co=0.125mg/ml. By using a glass column of (1.5cm) I.D and (50cm) length, packed with adsorbent of DEAE-cellulose of height (7cm). The influent is introduced in to the column using peristaltic pump and the effluent concentration is investigated using UV-spectrophotometer at 30oC and 280nm wavelength. A spread (steeper) break-through curve is gained

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Detection of line shape parameters in normal and abnormal biological tissues
...Show More Authors

Doppler broadening technique is suggested to monitor the development of tumours. It depends on the sensitivity of positronium (Ps) annihilation parameters to the sub- microstructural changes in biological tissues. This technique uses high resolution HpGe detector to measure the lineshape parameters (S and W) in normal mice's mammary tissues and adenocarcinoma mammary tissues as a function of tumour growth. The results demonstrate that the central parameter (S) decreases and the wing parameter (W) increases as the tumour grow. It is found that the S parameter changes considerably with the distribution of voids which are affected by the tumour development. Therefore the present technique can successfully be employed to monitor the developm

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 15 2024
Journal Name
Iraqi Journal Of Science
Investigating the Correlations between Physical Parameters of Elliptical and Lenticular Galaxies
...Show More Authors

This study aims to investigate the features of stellar-gaseous kinematics and dynamics mass using scaling coefficient relationships (such as the Faber–Jackson relation (FJR)) of two samples of elliptical and lenticular galaxies. These two samples of 80 ellipticals and 97 lenticulars were selected from previous literature works. The Statistical Package for Social Sciences )SPSS( and Matrix Laboratory (MATLAB) program were used to find out the associations of multiple factors under investigation such as main kinematic properties of the gaseous-stellar (effective radius Re, surface density within the effective radius (Ʃeff) , stellar mass in the blue band (Mstar (B)), gas mass ( Mgas), dynamic (Mdyn) and baryonic (Mbar), supermassiv

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Indium doped ZnO Urbach energy and dispersion parameters of thin films
...Show More Authors

The characterization of ZnO and ZnO:In thin films were confirmed by spray pyrolysis technique. The films were deposited onto glass substrate at a temperature of 450°C. Optical absorption measurements were also studied by UV-VIS technique in the wavelength range 300-900 nm which was used to calculate the optical constants. The changes in dispersion and Urbach parameters were investigated as a function of In content. The optical energy gap was decreased and the wide band tails were increased in width from 616 to 844 eV as the In content increased from 0wt.% to 3wt.%. The single–oscillator parameters were determined also the change in dispersion was investigated before and after doping.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jun 11 2017
Journal Name
Al-academy
The reflection of diode technology light emitting (LED) on the modular design of external lighting
...Show More Authors

Search marked (the reflection of diode technology light emitting (LED) on the modular design of external lighting) is an analytical study of the units, external lighting for gardens and adopted in its work on the diode technology emitting light to reach the magnitude of the effect and the change happening where according to this technique was the problem of the research in which is (what emotion the formal and functional units of external lighting according diode technology light emitting) and identified in the first part of it, including the goals came Search of b (statement reversal winning technical transformation of lighting from incandescent bulbs to light emitting diode technology (LED) on each of shape design and the nature of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Engineering
Influence of Design Efficiency of Water Supply Network Inside Building on its Optimum Usage: Review
...Show More Authors

The water supply network inside the building is of high importance due to direct contact with the user that must be optimally designed to meet the water needs of users.  This work aims to review previous research and scientific theories that deal with the design of water networks inside buildings, from calculating the amount of consumption and the optimal distribution of the network, as well as ways to rationalize the use of water by the consumer.  The process of pumping domestic water starts from water treatment plants to be fed to the public distribution networks, then reaching a distribution network inside the building till it is  provided to the user.  The design of the water supply network inside the building is

... Show More
View Publication Preview PDF
Crossref