Exposure of reinforced concrete buildings to an accidental fire may result in cracking and loss in the bearing capacity of their major components, columns, beams, and slabs. It is a challenge for structural engineers to develop efficient retrofitting techniques that enable RC slabs to restore their structural integrity, after being exposed to intense fires for a long period of time. Experimental
investigation was carried out on twenty one slab specimens made of self compacting concrete, eighteen of them are retrofitted with CFRP sheets after burning and loading till failure while three of them (which represent control specimens) are retrofitted with CFRP sheet after loading till failure without burning. All slabs had been tested in a simply supported span and subjected to two-point loading. The main variables were the effect of different temperature levels (300ºC, 500ºC and 700ºC),different concrete compressive strength (20MPa, 30MPa and 40MPa) and cooling rate (gradually and sudden cooling conditions) on the behavior of retrofitted one way slabs .The structural response of each slab specimen was investigated in terms of load-deflection behavior, ultimate load carrying
capacity and mode of failure. The experimental results, generally, indicate that slabs retrofitted using CFRP sheets restored flexural strength values nearly equal to or lower than those of the reference slabs, the retrofitted slabs exhibited larger deflection than the control slabs at ultimate loads. Retrofitted control slabs after loading regained about 93.95% to 97.92% of their original load capacity
(before retrofitting) while the other slabs regained from 42.% to 84% of the load capacity of the original control specimens. Most of the tested slabs failed by concrete crushing at mid span and partial debonding of certain retrofitting systems was also observed for a few cases
The study aimed to assess Milk Thistle oi reducing the aflatoxin damage and improve the health status of local breed hens. The study was performed on 60 hens aged 35 weeks, weighing 2-2.5 kg of the body was obtained and housed on a private poultry farm in north of Baghdad (Altaji) for a period of 9 weeks from 22 October until 22 December 2020. Hens were divided to three treatments (20 hens). The first was fed a basal diet free of aflatoxin. The 2nd fed on a contaminated diet with aflatoxin (14.6 ppb) while the 3rd fed as in the 2nd with 0.5% of Milk Thistle oil /kg feed. A 5 hens from each group were slaughtered at the end of the trial for the histopathological inspection of liver, spleen and intestine tissues to evaluate the harmfu
... Show MoreThe historic cities in the Arab and Islamic world (including the cities of the holy shrines in Iraq) suffer from many and varied problems and most notably it is clear in its origin functional structure. It had been transformed from a basic place to live for a few thousand of the population to the center or part of the main center of large city populations of more than one million. Functional structure of the ancient city have been change with the beginning of the twentieth century and accelerated rate of change in the second half of the last century. The research aims to analyze the problems of the historic centers of holy cities and analyze the methods of dealing with these problems, leading to discrimination method could be the
... Show MoreA field experiment was conducted at the field of the Dept. of Field Crop Sci. / College of Agriculture / University of Baghdad . The objective was to determine the values of relative constant of three – way and double crosses of maize . Ten inbreds were used and crossed during spring and fall seasons of 2009 to produce three - way and double crosses , and ten hybrids were taken from each group . The ten hybrids were grown and selfed during spring 2010 to produce 2 seed . Three way and double crosses were sown with their parents and 2 seed during fall 2010 in RCBD with four replicates . Leaf area , total dry matter , row/ear , grain/ear , grain weight and grain weight/plant of hybrids , parents and 2 plants were taken . Results showed that
... Show MoreIn the 1980s, the French Administration Roads LCPC developed high modulus mixtures (EME) by using hard binder. This type of mixture presented good resistance to moisture damage and improved mechanical properties for asphalt mixtures including high modulus, good fatigue behaviour and excellent resistance to rutting. In Iraq, this type of mixture has not been used yet. The main objective of this research is to evaluate the performance of high modulus mixtures and comparing them with the conventional mixture, to achieve this objective, asphalt concrete mixes were prepared and then tested to evaluate their engineering properties which include moisture damage, resilient modulus, permanent deformation and fatigue characteristics. These pro
... Show MoreThe behavior investigation of castellated beams with fiber-reinforced lightweight concrete deck slab as a modified choice for composite steel-concrete beams affected by harmonic load is presented in this study. The experimental program involved six fixed-supported castellated beams of 2140mm size. Three types of concrete were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber-Reinforced Aggregate Concrete (LWACF). The specimens were divided into two groups: the first comprised three specimens tested under harmonic load effect of 30Hz operation frequency for 3 days, then the residual strength was determined through static load application. The second group included three specimens ide
... Show MoreThis manuscript investigated the effect of anchorage CFRP wrapping sheets, bolts, and laminate interlock on increasing the efficiency of flexural strengthening for the post-tension girder using CFRP composites techniques longitudinal laminates at the soffit for partially damaged loss of about 14.3% from its area of prestressed concrete beams, and the impact on restoring the original flexural capacity of PC girder. Mitigating delamination of the soffit of horizontal laminates (CFRP). The texture of the laminate and anchorages influenced the stress of the laminate carbon fiber, the mode of crack propagation and failure, and consequently, the beam's attitude has been investigated in this manuscript. The experimental findi
... Show MoreChanges in mechanical properties of material as a result of service in different conditions can be provided by mechanical testing to assist the estimation of current internal situation of these materials, or the degree of deterioration may exist in furnaces serviced at high temperature and exceed their design life. Because of the rarity works on austenitic stainless steel material type AISI 321H, in this work, ultimate tensile strength, yield strength, elongation, hardness, and absorbed energy by impact are evaluated based on experimental data obtained from mechanical testing. Samples of tubes are extracted from furnace belong to hydrotreaterunit, also samples from un-used tube material are used to make comparisons between these properti
... Show More