Preferred Language
Articles
/
joe-2243
Structural Behavior of Reinforced Concrete Hollow Beams under Partial Uniformly Distributed Load
...Show More Authors

A Longitudinal opening is used to construct hollow core beam is a cast in site or precast or pre stressed concrete member with continuous voids provided to reduce weight, cost and, as a side benefit, to use for concealed electrical or mechanical runs. Primarily is used as floor beams or roof deck systems. This study investigate the behavior of six beams (solid or with opening) of dimension (length 1000 x height 180 x width120mm) simply support under partial uniformly distributed load, four of these beam contain long opening of varied section (40x40mm) or (80x40mm). The effect of vertical steel reinforcing, opening size and orientations are investigated to evaluate the response of beams. The experimental behavior based on load-deflection measured at central and quarter of tension zones. The experimental test result shows the presence of Hollow decrease the load carrying capacity by about (37.14% to 58.33%) and increased the deflections by about (71.6% for (Hollow ratio 7.4%) to 75.5% for (Hollow ratio 14.8%)) for same applied load
compared with solid beams with the same properties. The increase shear steel reinforcing will decrease all the deformations at all stages of loading, but particularly after initial cracking and give enhancement in ultimate load capacity of beams by about 31.5% with increasing the amount of shear steel reinforcing by about 50%. Finally, ductility is increased in all cases under partial uniformly distributed load when hollow ratio decreased by about 50% or increased in shear steel reinforcing by about 50%

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Engineering
A Realistic Aggregate Load Representation for A Distribution Substation in Baghdad Network
...Show More Authors

Electrical distribution system loads are permanently not fixed and alter in value and nature with time. Therefore, accurate consumer load data and models are required for performing system planning, system operation, and analysis studies. Moreover, realistic consumer load data are vital for load management, services, and billing purposes. In this work, a realistic aggregate electric load model is developed and proposed for a sample operative substation in Baghdad distribution network. The model involves aggregation of hundreds of thousands of individual components devices such as motors, appliances, and lighting fixtures. Sana’a substation in Al-kadhimiya area supplies mainly residential grade loads. Measurement-based

... Show More
View Publication Preview PDF
Publication Date
Sun May 01 2016
Journal Name
Istanbul Bridge Conference.- Turkey
Strengthening and Load Testing for Short Span Steel Bridge for Abnormal Loads
...Show More Authors

The steel jetty selected for strengthening is in Baghdad city, over Tigris River, consists of 55 short spans, each of approximately 4 meters and one naviga-tional opening of 12 m. The bridge is 224 meters length and 8 meters in width. The strengthening system was designed to remove overstresses that occurred when the bridge was subjected to abnormal loads of 380 tons. A strengthening system which installed in spring 2008 was used where the main concept is to depend on added side supporting elements which impose reversal forces on the bridge to counteract most of the loads expected from the abnormal heavy loads. The bridge was load tested before and after the strengthening system was activated. The load test results indicate that the strengt

... Show More
Publication Date
Fri Feb 05 2021
Journal Name
Research In Intelligent And Computing In Engineering
Implementing Web Testing System Depending on Performance Testing Using Load Testing Method.
...Show More Authors

Web testing is very important method for users and developers because it gives the ability to detect errors in applications and check their quality to perform services to users performance abilities, user interface, security and other different types of web testing that may occur in web application. This paper focuses on a major branch of the performance testing, which is called the load testing. Load testing depends on an important elements called request time and response time. From these elements, it can be decided if the performance time of a web application is good or not. In the experimental results, the load testing applied on the website (http://ihcoedu.uobaghdad.edu.iq) the main home page and all the science departments pages. In t

... Show More
Publication Date
Wed Dec 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Properties of High Performance Concrete
...Show More Authors

The research deals with a new type of high-performance concrete with improved physical properties, which was prepared by using metal additives minutes (Metakaolin) and by studing their impact on the properties of mortar and concrete high-performance through destructive and non destructive tests. This type of concrete is used broadly in public buildings and in other structures . The research involved a number of experiments such as finding the activity index of burned at a temperature of 750 º C according to the standard ( ASTM C-311/03), as well as casting models for the cubic mortar mixtures and concrete containers at different rates of metakaolin ranging between (5% - 20%) as an added part to the cement mix to get a high- compressive

... Show More
View Publication Preview PDF
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Producing Sustainable Roller Compacted Concrete by Using Fine Recycled Concrete Aggregate
...Show More Authors

One-third of the total waste generated in the world is construction and demolition waste. Reducing the life cycle of building materials includes increasing their recycling and reuse by using recycled aggregates. By preventing, the need to open new aggregate quarries and reducing the amount of construction waste dumped into landfills, the use of recycled concrete aggregate in drum compacted concrete protects the environment. Four samples of PRCC were prepared for testing (compressive strength, tensile strength, flexural strength, density, water absorption, porosity) as the reference mix and (10, 15, and 20%) of fine recycled concrete aggregate as a partial replacement for fine natural aggregate by volume. The mix is designed according to

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Jul 20 2019
Journal Name
Al-nahrain Journal For Engineering Sciences
Inducing Frictional Force to Enhance the Transient Response in Beams
...Show More Authors

This paper studies the effect of contact areas on the transient response of mechanical structures. Precisely, it investigates replacing the ordinary beam of a structure by two beams of half the thickness, which are joined by bolts. The response of these beams is controlled by adjusting the tightening of the connecting bolts and hence changing the magnitude of the induced frictional force between the two beams which affect the beams damping capacity. A cantilever of two beams joined together by bolts has been investigated numerically and experimentally. The numerical analysis was performed using ANSYS-Workbench version 17.2. A good agreement between the numerical and experimental results has been obtained. In general, results s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Sn Applied Sciences
Regressor-free adaptive vibration control of constrained smart beams with axial stretching
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jul 03 2016
Journal Name
Journal Of Educational And Psychological Researches
School Refusal Behavior of Primary First Class Pupils in Baghdad
...Show More Authors

Objectives: The study aims to assess the school refusal behavior of first class pupils at primary schools and identifying the relationship between the school refusal behavior and some of socio-demographic characteristics for the pupils.

Methodology:  A descriptive-analytic study was initiated from November 1st, 2012 to April 1st, 2013. A random sample of 411 students is selected from a probability stratified sample of 17 primary schools for both sexes in 4 sectors in Baghdad Al-Rasafa and Al-Karkh districts which are selected randomly from first class of primary school. A Self administrative questionnaire (Parents' Version) which constructed by the rese

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
In-Vitro evaluation of load-deflection characteristics and force levels of nickel titanium orthodontic archwires
...Show More Authors

Background: Nickel-titanium (NiTi) archwires have become increasingly popular because of their ability to release constant light forces, which are especially useful during initial alignment and leveling phase. The aim of the present study was to investigate and compare the load–deflection characteristics of four commercially available NiTi archwires. Materials and methods: 200 NiTi 0.014, 0.016, 0.018, 0.016x0.022 and 0.019x0.025-inch nickel–titanium archwires from four different manufacturers (3M, Ortho Technology, Jiscop and Astar) were tested. The load-deflection properties of these archwires were evaluated by a full arch bending test in both palatal and gingival directionsat 37°C temperature using a universal material t

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 28 2019
Journal Name
Journal Of Mechanics Of Continua And Mathematical Sciences
NEW ROBUST ESTIMATOR OF CHANGE POINT IN SEGMENTED REGRESSION MODEL FOR BED-LOAD OF RIVERS
...Show More Authors

View Publication Preview PDF
Clarivate Crossref