Preferred Language
Articles
/
joe-2194
Performance Analysis of Four Conceptual Designs for the Air Based Photovoltaic / Thermal Collectors
...Show More Authors

The  thermal  and  electrical  performance  of  different  designs  of  air  based  hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and lower surfaces of PV panels, air temperature, air flow rate, air pressure drop, wind speed, solar radiation and ambient temperature were measured. The power produced by solar cells is measured also. A theoretical model has been developed for the collector model IV based on energy balance principle. The prediction of the thermal and hydraulic performance was obtained for the fourth model of PV/T collector by developing a Matlab computer program to solve the numerical model. The experimental results show that the combined efficiency of model III is higher than that of models II and IV. The pressure drop of model III is less than that of models I and IV, by (43.67% and 49%). The average percentage error between the theoretical and experimental results was 9.67%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Advanced Research
UV Photovoltaic detector based on Bi doped TiO2 Fabricated by Pulse Laser Deposition
...Show More Authors

Pure and doped TiO 2 with Bi films are obtained by pulse laser deposition technique at RT under vacume 10-3 mbar, and the influence of Bi content on the photocvoltaic properties of TiO 2 hetrojunctions is studied. All the films display photovoltaic in the near visible region. A broad double peaks are observed around λ= 300nm for pure TiO 2 at RT in the spectral response of the photocurrent, which corresponds approximately to the absorption edge and this peak shift to higher wavelength (600 nm) when Bi content increase by 7% then decrease by 9%. The result is confirmed with the decreasing of the energy gap in optical properties. Also, the increasing is due to an increase in the amount of Bi content, and shifted to 400nm when annealed at 523

... Show More
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Heat Transfer Analysis of Conventional Round Tube and Microchannel Condensers in Automotive Air Conditioning System
...Show More Authors

In this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Nov 01 2025
Journal Name
Kufa Journal Of Engineering
SIMULATION FOR PERFORMANCE EVALUATION OF SATELLITE-BASED QUANTUM COMMUNICATION SYSTEM
...Show More Authors

The selection and assessment of single-photon detection modules is a crucial problem in satellite-based QKD systems. The system's overall efficiency, secure key rate and quantum bit error rate are all significantly influenced by single-photon detection modules. There is a knowledge gap about the practical performance of commercially available single-photon detectors because existing research frequently relies on theoretical characteristics. This paper introduces a study on the effect of the parameters of three commercial single photon detection modules from ID Quantique company: ID Qube, ID100, and ID281 on certain Bennett-Brassard 1984 protocol parameters such as secure key rate, mean photon number per pulse, quantum bit error rate

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
2014 International Conference On Computer And Information Sciences (iccoins)
Proposed conceptual model for E-service quality in Malaysian universities
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Jun 01 2025
Journal Name
مجلة الترجمة واللسانيات
CONCEPTUAL INDEX OF ORKHUN INSCRIPTIONS
...Show More Authors

In this study, we came across various concepts in the three major Gokturk inscriptions, namely Kul Tigin, Bilge Kagan and Tunyukuk. We classified these concepts under 33 main headings such as “proper names, geography, cities, tribe, descriptive names, colors, language materials, time, plants, animals, humans, kinship, titles and ranks, professions, identity, bodun, number, politics, trade, art, wealth and poverty, religion and belief, ceremony” etc. In our study, we only considered the words that constitute nouns. While preparing the conceptual index, we divided a large part of these 33 main headings into various subheadings. We listed the words alphabetically. Since we detected different meanings of some of the headings in our index, w

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
The effect of changing the evacuated tube tilt angle and the fluid of the solar collector on the performance of a hybrid solar air conditioning system
...Show More Authors

In the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Multi-pages structure for Six Sigma performance matrix based on the technical characteristics of balanced performance and methodology Al-Sigma for measuring corporate performance: Suggestion vision
...Show More Authors

Accelerates operating managements in the facilities contemporary business environment toward redefining processes and strategies that you need to perform tasks of guaranteeing them continue in an environment performance dominated by economic globalization and the circumstances of uncertainty attempt the creation of a new structure through multiple pages seek to improve profitability and sustainable growth in performance in a climatefocuses on the development of institutional processes, reduce costs and achieve customer satisfaction to meet their demands and expectations are constantly changing. The research was presented structural matrix performance combines methodology Alsigma in order to improve customer satisfaction significantly bet

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
A study of the Effect of Air Inlet and Exit on Indoor Air Movement
...Show More Authors

This work consists of a numerical simulation to predict the velocity and temperature distributions, and an experimental work to visualize the air flow in a room model. The numerical work is based on non-isothermal, incompressible, three dimensional, k turbulence model, and solved using a computational fluid dynamic (CFD) approach, involving finite volume technique to solve continuity, momentum and energy equations, that governs the room’s turbulent flow domain. The experimental study was performed using (1/5) scaled room model of the actual dimensions of the room to simulate room air flow and visualize the flow pattern using smoke generated  from burnt herbs and collected in a smoke generator to delivered through

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 13 2024
Journal Name
Journal Of Advanced Research In Fluid Mechanics And Thermal Sciences
Influence of Surrounding Air Temperature and Humidity upon the Performance of a Gas Turbine Power Plant
...Show More Authors

Nowadays, energy demand continuously rises while energy stocks are dwindling. Using current resources more effectively is crucial for the world. A wide method to effectively utilize energy is to generate electricity using thermal gas turbines (GT). One of the most important problems that gas turbines suffer from is high ambient air temperature especially in summer. The current paper details the effects of ambient conditions on the performance of a gas turbine through energy audits taking into account the influence of ambient conditions on the specific heat capacity ( , isentropic exponent ( ) as well as the gas constant of air . A computer program was developed to examine the operation of a power plant at various ambient temperature

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Tue Dec 13 2022
Journal Name
Frontiers In Chemistry
Numerical analysis of the energy-storage performance of a PCM-based triplex-tube containment system equipped with arc-shaped fins
...Show More Authors

This study numerically intends to evaluate the effects of arc-shaped fins on the melting capability of a triplex-tube confinement system filled with phase-change materials (PCMs). In contrast to situations with no fins, where PCM exhibits relatively poor heat response, in this study, the thermal performance is modified using novel arc-shaped fins with various circular angles and orientations compared with traditional rectangular fins. Several inline and staggered layouts are also assessed to maximize the fin’s efficacy. The effect of the nearby natural convection is further investigated by adding a fin to the bottom of the heat-storage domain. Additionally, the Reynolds number and temperature of the heat-transfer fluid (HTF) are e

... Show More
Scopus (56)
Crossref (47)
Scopus Clarivate Crossref