This work consists of a numerical simulation to predict the velocity and temperature distributions, and an experimental work to visualize the air flow in a room model. The numerical work is based on non-isothermal, incompressible, three dimensional, k turbulence model, and solved using a computational fluid dynamic (CFD) approach, involving finite volume technique to solve continuity, momentum and energy equations, that governs the room’s turbulent flow domain. The experimental study was performed using (1/5) scaled room model of the actual dimensions of the room to simulate room air flow and visualize the flow pattern using smoke generated from burnt herbs and collected in a smoke generator to delivered through the prototype room. The numerical results were compared with those obtained from experiments, the correspondence between numerical and experimental was fairly good and also, a fair comparison was found with other workers in this field.
Experimental and numerical studies have been conducted for the effect of injected air bubbles on the heat transfer coefficient through the water flow in a vertical pipe under the influence of uniform heat flux. The investigated parameters were water flow rate of (10, 14 and 18) lit/min, air flow rate of (1.5, 3 and 4) lit/min for subjected heat fluxes of (27264, 36316 and 45398) W/m2. The energy, momentum and continuity equations were solved numerically to describe the motion of flow. Turbulence models k-ε was implemented. The mathematical model is using a CFD code Fluent (Ansys15). The water was used as continuous phase while the air was represented as dispersed. phase. The experimental work includes design, build and instrument a test
... Show MoreThe effect of air injection angle on the performance of airlift pump used for water pumping has been studied analytically and experimentally. An airlift pump of dimensions 42mm diameter and 2200 mm length with conventional and modified air injection device was considered. A modification on conventional injection device (normal air-jacket type) was carried out by changing injection angle from 90 (for conventional) to 45 and 22.5 (for modified). Continuity and one-dimensional momentum balance for the flow field with basic principle of two-phase flow and expressions of slip ratio and friction factor as function of flow rates were formulated. The analytical and experimental investigations were carried out f
... Show MoreTo add more details about the effect of the axial magnetic field on the plasma profile, the breakdown voltage of air was investigated at low pressure (9-15 Pa) in the presence of axial magnetic field (0.01-0.04T). The air was ignited by a DC voltage between two plain electrodes of aluminum separated by a distance (8.5cm). The measurements showed that the discharge voltage decreases to a minimum value, then returns to increase over the minimum with increasing the magnetic field strength, at all pressures in the range. It was also observed that a maximum decrease in the discharge voltage is obtained near the minimum of Paschen curve from the right side. The decrease in the discharge voltage was caused mainly by the effect of magnetic
... Show MoreThe preferable design for unsaturated symmetrical spherical
double-pole piece electron lens required good focal properties, and in this present study investigate effect of air gap wide (S) on the properties of the projector lens specialized the minimum projector
focal length 1Fr) . and the properties of the axial magnetic field
\ lnlll
distribution:(the maximum
... Show MoreThis paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. laboratory tests were performed on a direct evaporative cooler (DEC) followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was (68%). The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, satura
... Show MoreAir pollution is one of the complex problems plaguing the environment at the present time
as a result of many liberation of gases, vapors and fumes of fuels and chemicals resulting
from industrial activities . It should be noted that there are some elements of the heavy
(Heavy Metals), including toxic in the air, with different concentrations in the air depending
on the nature of the area, for example be in rural areas is lower than in cities or industrial
areas as measured parts million (ppm ) or parts per billion (ppb). Some of these important
elements in the physiological processes and enzymatic organisms but become toxic and
Qatlhand-increase Tercisahaan the permissible limits Bhave nature ,The air contaminant
Air pollution is one of the complex problems plaguing the environment at the present time
as a result of many liberation of gases, vapors and fumes of fuels and chemicals resulting
from industrial activities . It should be noted that there are some elements of the heavy (Heavy
Metals), including toxic in the air, with different concentrations in the air depending on the
nature of the area, for example be in rural areas is lower than in cities or industrial areas as
measured parts million (ppm ) or parts per billion (ppb). Some of these important elements in
the physiological processes and enzymatic organisms but become toxic and Qatlhand-increase
Tercisahaan the permissible limits Bhave nature ,The air contaminant co
Membrane distillation (MD) is a hopeful desalination technique for brine (salty) water. In this research, Direct Contact Membrane Distillation (DCMD) and Air Gap Membrane Distillation (AGMD) will be used. The sample used is from Shat Al –Arab water (TDS=2430 mg/l). A polyvinylidene fluoride (PVDF) flat sheet membrane was used as a flat sheet form with a plate and frame cell. Several parameters were studied, such as; operation time, feed temperature, permeate temperature, feed flow rate. The results showed that with time, the flux decreases because of the accumulated fouling and scaling on the membrane surface. Feed temperature and feed flow rate had a positive effect on the permeate flux, while permeate temperatu
... Show MoreIn this work, a flat-plate solar air heater (FSAH) and a tubular solar air heater (TSAH) were designed and tested numerically. The work investigates the effect of increasing the contact area between the flowing air and the absorber surface of each heater and predicts the expected results before the fabrication of the experimental rig. Three-dimensional two models were designed and simulated by the ANSYS-FLUENT 16 Program. The solar irradiation and ambient air temperature were measured experimentally on December 1st 2022, at the weather conditions of Baghdad City- Iraq, at three air mass flow rates, 0.012 kg/s, 0.032 kg/s, and 0.052 kg/s. The numerical results showed the advantage in the thermal performance of
... Show MoreKinetics study on the phenol oxidation by catalytic wet air oxidation (CWAO) using CuO.NiO/Al2O3 as heterogeneous catalyst is presented. 4 g/l phenol solution of pH 7.3 was oxidized in a trickle bed reactor with gas flow rate of 80% stochiometric excess (S.E).. In order to verify the proposed kinetics, a series of CWAO experimental tests were done at two temperatures (140 and 160° C), oxygen partial pressures (9 and 12 bar), and weight hourly space velocity (WHSV) (1, 1.5, 2, 2.5, and 3 h-1). According to Power Law, the reaction orders are found to be approximately 1 and 0.5 with respect to phenol concentration and oxygen solubility, respectively. These values favorably compare with those cited in the literature for intrinsic kinetics,
... Show More