Preferred Language
Articles
/
joe-2182
Removal of 4-Chlorophenoles from Simulated Wastewater by Advanced Oxidation Processes
...Show More Authors

The degradation and mineralization of 4-chlorophenol (4-CP) by advanced oxidation processes (AOPs) was investigated in this work, using both of UV/H2O2 and photo-Fenton UV/H2O2/Fe+3 systems.The reaction was influenced by the input concentration of H2O2, the amount of the iron catalyst, the type of iron salt, the pH and the concentration of 4-CP. A colored solution of benzoquinon can be observed through the first 5 minutes of irradiation time for UV/H2O2 system when low concentration (0.01mol/L) of H2O2 was used. The colored solution of benzoquinon could also be observed through the first 5 minutes for the UV/H2O2/Fe+3 system at high
concentration (100ppm) of 4-CP. The results have shown that adding Fe+3 to the UV/H2O2 system enhanced the rate of 4-CP oxidation at a molar ratio of H2O2/Fe+3/4-CP equals to 13/0.4/1 by a factor of 7. This reduced the consumption of H2O2 by a factor of 6 and the irradiation time required for complete degradation was reduced by a factor of 6. The experimental results have shown that the optimum reagents for a complete degradation of 4-CP(50ppm) were H2O2.=0.005mol/L, Fe+3=0.16*10-3 mol/L under acidic
condition (pH=3) and irradiation time of 15 min for the UV/H2O2/Fe+3 system with a molar ratio of H2O2/Fe+3/4-CP equals to 13/0.4/1.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 04 2024
Journal Name
Journal Of Engineering
REMOVAL OF DIRECT BLUE DYE IN TEXTILEWASTEWATER EFFLUENT BY ELECTROCOAGULATION
...Show More Authors

 Removal of direct blue dye by electrocoagulation method has been investigated using aluminum   electrode in a bench-scale electrochemical system. Current density, NaCl concentration,   electrocoagulation time, and dye concentration has been studied as effecting parameters in color   removal efficiency. Increasing of current density will increase the color removal efficiency and   energy consumption as well. While increasing NaCl concentration increase the color removal   efficiency but it decrease energy consumption. High dye concentration is needed for extra   electrocaogolation time to reach the same efficiency that obtained with low dye concentration .With   current applied 0.35 amps. and NaCl concentration of 2 g/l more

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Bioadsorption of Heavy Metals From Industrial Wastewater Using Some Species of Bacteria
...Show More Authors

Three isolated bacteria were examined to remove heavy metals from the industrial wastewater of the Diala State Company of Electrical Industries, Diyala-Iraq. The isolated bacteria were identified as Pseudomonas aeruginosa, Escherichia coli and Sulfate Reducing Bacteria (SRB). The three isolates were used as an adsorption factor for different concentrations of Lead and Copper (100, 150, and 200 ppm.), in order to examine the adsorption efficiency of these isolates. In addition, the effect of three factors on heavy metals adsorption were examined; temperature (25, 30, and 37 ?C), pH (3 and 4.5) and contact time (2 and 24 hrs). The results showed that the highest level of lead adsorption was obtained at 37 ?C by E. coli, P, aerugenosa and

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Separation And Purification Technology
Application of central composite design approach for optimisation of zinc removal from aqueous solution using a Flow-by fixed bed bioelectrochemical reactor
...Show More Authors

View Publication
Scopus (19)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Separation And Purification Technology
Application of central composite design approach for optimisation of zinc removal from aqueous solution using a Flow-by fixed bed bioelectrochemical reactor
...Show More Authors

View Publication
Scopus (19)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Effect of chelating agents on removal of 137Cs from contaminated soil
...Show More Authors

In the present research, the chemical washing method has been selected using three chelating agents: citric acid, acetic acid and Ethylene Diamine Tetraacetic Acid (EDTA) to remove 137Cs from two different contaminated soil samples were classified as fine and coarse grained. The factors that affecting removal efficiency such as type of soil, mixing ratio and molarity have been investigated. The results revealed that no correlation relation was found between removal efficiency and the studied factors. The results also showed that conventional chemical washing method was not effective in removing 137Cs and that there are further studies still need to achieve this objective.

View Publication Preview PDF
Crossref
Publication Date
Thu May 05 2022
Journal Name
Karbala International Journal Of Modern Science
Heterogeneous catalytic degradation of dye by Fenton-like oxidation over a continuous system based on Box–Behnken design and traditional batch experiments
...Show More Authors

In this study, iron was coupled with copper to form a bimetallic compound through a biosynthetic method, which was then used as a catalyst in the Fenton-like processes for removing direct Blue 15 dye (DB15) from aqueous solution. Characterization techniques were applied on the resultant nanoparticles such as SEM, BET, EDAX, FT-IR, XRD, and zeta potential. Specifically, the rounded and shaped as spherical nanoparticles were found for green synthesized iron/copper nanoparticles (G-Fe/Cu NPs) with the size ranging from 32-59 nm, and the surface area was 4.452 m2/g. The effect of different experimental factors was studied in both batch and continuous experiments. These factors were H2O2 concentration, G-Fe/CuNPs amount, pH, initial DB15

... Show More
View Publication
Scopus (11)
Crossref (7)
Scopus Crossref
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Treatment of Wastewater of Alcohol Factory by Filtration as Primary Treatment
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Sep 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Sorption of Nitrate Salts from Wastewater without and with Modification Orange Peel
...Show More Authors

This investigation deals with the use of orange peel (OP) waste as adsorbent for removal of nitrate (NO3) from simulated wastewater. Orange peel prepared in two conditions dried at 60C° (OPD) and burning at 500 °C (OPB). The effect of pH: 2-10, contact time: 30- 180 min, sorbent weight: 0.5- 3.0 g were considered. The optimal pH value for NO3 adsorption was found to be 2.0 for both adsorbents. The equilibrium data were analyzed using Langmuir and  Freundlich isotherm models. Freundlich model was found to fit the equilibrium data very well with high-correlation coefficient (R2). The adsorption kinetics was found to follow pseudo-second-order rate kinetic model, with a good correlation (R2

... Show More
View Publication Preview PDF
Publication Date
Fri May 03 2019
Journal Name
Photonics
Design Investigation of 4 × 4 Nonblocking Hybrid Plasmonic Electrooptic Switch
...Show More Authors

This paper proposes a compact, plasmonic-based 4 × 4 nonblocking switch for optical networks. This device uses six 2 × 2 plasmonic Mach-Zehnder switch (MZS), whose arm waveguide is supported by a JRD1 polymer layer as a high electro-optic coefficient material. The 4 × 4 switch is designed in COMSOL environment for 1550 nm wavelength operation. The performance of the proposed switch outperforms those of conventional (nonplasmonic) counterparts. The designed switch yields a compact structure ( 500 × 70   µ m 2 ) having V π L = 12   V · µ m , 1.5 THz optical bandwidth, 7.7 dB insertion loss, and −26.5 dB crosstalk. The capability of the switch to route 8 × 40 Gbps WDM signal is demonstrated successfully.

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jun 09 2021
Journal Name
Design Engineering
The Impact of Transforming the Educational System in Iraq from 6-3-3 to 4-4-4 on Educational Planning Standards and the Deficiency of School Buildings (Primary and Secondary Education)
...Show More Authors

        Educational services in Iraq face many problems that have reduced the efficiency of the educational process, as a result of the difficult conditions experienced by educational services in Iraq. This led to the accumulation of these problems and their exacerbation significantly over the years, as there was no fundamental solution to these problems. The study proposes a planning method for managing the educational system in Iraq, especially for the primary and secondary levels, where these negative phenomena are very prominent, especially the deficit in school buildings and the phenomenon of overcrowding in classrooms.      &am

... Show More
View Publication Preview PDF