Preferred Language
Articles
/
joe-2180
Fatigue Analysis of Hip Prosthesis
...Show More Authors

The present work covers the analytical design process of three dimensional (3-D) hip joint prosthesis with numerical fatigue stress analysis. The analytical generation equations describing the different stem constructive parts (ball, neck, tour, cone, lower ball) have been presented to reform the stem model in a mathematical feature. The generated surface has been introduced to FE solver (Ansys version 11) in order to simulate the induced dynamic stresses and investigate the effect of every design parameter (ball radius, angle of neck, radius of neck, neck ratio, main tour radius, and outer tour radius) on the max. equivalent stresses for hip prosthesis made from titanium alloy. The dynamic loading case has been studied to a stumbling case. The load has been applied on the cap tip as a concentrated load distributed on the interface of ball and socket. The results show that the decreasing of max. Fatigue stress by (175) MPa could be obtained by increasing the outer tour radius from (10)mm to (15) mm and that will change the max. Fatigue zone location from the tour section to the neck. The ball radius and neck angle must be as lower as possible to decrease the fatigue stresses. The most dominate parameter to increase the safety factor is the radius of neck.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of The Faculty Of The Medicine Baghdad
Do low back pain changes correlate with sagittal lumbar alignment changes after total hip replacement arthroplasty?
...Show More Authors

Abstract Background: The hip joint and lumbar spine are both anatomically and functionally closely related as had shown by many authors. So the abnormality in one area can affect the other e.g. hip joint osteoarthritis can cause lumbar sagittal malalignment and backache. Objectives: is to see if there is significant improvement in backache after total hip replacement? And which degree of backache improvement is associated with significant changes in lumbar lordosis? Methods and patients: a prospective open trial study was performed on 30 patients who had severe hip osteoarthritis and chronic low back pain. Total hip replacement was performed to all patients. Backache and lumbar lordosis were measured by visual analogue scale and Cobb’s a

... Show More
Preview PDF
Publication Date
Sat Sep 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Influence of Nanoreinforced Particles (Al2O3) on Fatigue Life and Strength of Aluminium Based Metal Matrix Composite
...Show More Authors

Abstract

     In this investigation, Al2O3 nano material of 50nm particles size were added to the 6061 Al aluminium alloy by using the stir casting technique to fabricate the nanocomposite of 10wt% Al2O3. The experimental results observed that the addition of 10wt% Al2O3 improved the fatigue life and strength of constant and cumulative fatigue. Comparison between the S-N curves behaviour of metal matrix (AA6061) and the nanocomposite 10wt% Al2O3 has been made. The comparison revealed that 12.8% enhancement in fatigue strength at 107cycles due to 10wt% nano reinforcement. Also cumulative fatigue l

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Jul 01 2013
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Intramedullary Versus Extramedullary Alignment Guide for the Accurate Sagital Tibial Prosthesis Alignment in Total Knee Replacement Arthroplasty
...Show More Authors

Background: long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment, several studies have correlated poor outcome with malalignment of the components. The debate on the optimal system for femoral alignment is now largely resolved, but there is still controversy about whether intramedullary or extramedullary systems are better for the tibial side.

Objecives :  is to determine whether intramedullary or extramedullary tibial alignment guide is better for accurate sagital tibial prosthesis alignment in total knee replacement arthroplasty.

Patients and methods: Of 65 patients recruited, only 48 patients (55 knees) were met the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Fatigue and Tensile Characteristics for Composite Materials Used in Prosthetic Socket
...Show More Authors

In this research, the use of natural materials like wool and cannabis as intermediate reinforcement for prosthetic limbs due to their comfort, affordability, and local availability was discussed. As part of this study on below-the-knee (BK) prosthetic sockets, two sets of samples were made using a vacuum method. These sets were made of natural fiber-reinforced polymer composites with lamination 80:20: group (Y) had 4 perlon, 1 wool 4 perlon, and group (G) had 4 perlon, 1 cannabis 4 perlon. The two groups were compared with a socket made of polypropylene. Tensile testing was used to determine the mechanical characteristics of the socket materials. The Y group has a yield stress of 17 MPs, an ultimate strength of 18.75 MPa, and an elastic

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of Shot Peening on Fatigue Properties for Corroded and Uncorroded (CK35) Steel
...Show More Authors

The traction property is one of the important mechanical properties, especially the rotary parts which are subjected to constant and variable loads There are many methods used to improve this property, and the shoot peening by metal balls is considered the most critical one. the study focuses on this characteristic of steel CK35 used in many engineering applications as the rotating shafts and railway This study shows that the fatigue strength is improved by14% after shoot peening with metal balls. The study includs the rehabilitation of damaged samples as a result of fatigue corrosion. The standard solution adopted was 36% MgCl­2 with a 30 days immersion period. These samples has been improved by 6% after it decreased by18% d

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 30 2023
Journal Name
Mathematical Modelling Of Engineering Problems
Enhanced Prosthesis Control Through Improved Shoulder Girdle Motion Recognition Using Time-Dependent Power Spectrum Descriptors and Long Short-Term Memory
...Show More Authors

Surface electromyography (sEMG) and accelerometer (Acc) signals play crucial roles in controlling prosthetic and upper limb orthotic devices, as well as in assessing electrical muscle activity for various biomedical engineering and rehabilitation applications. In this study, an advanced discrimination system is proposed for the identification of seven distinct shoulder girdle motions, aimed at improving prosthesis control. Feature extraction from Time-Dependent Power Spectrum Descriptors (TDPSD) is employed to enhance motion recognition. Subsequently, the Spectral Regression (SR) method is utilized to reduce the dimensionality of the extracted features. A comparative analysis is conducted between the Linear Discriminant Analysis (LDA) class

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Comparison of the Cyclic Fatigue of Protaper Next, 2Shape and Hyflex EDM Using Glyde
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Study the Effects of Microwave Furnace Heat on The Mechanical Properties and Estimated Fatigue life of AA2024-T3
...Show More Authors

This research aims to study the effect of microwave furnace heat on the mechanical properties and fatigue life of aluminum alloy (AA 2024-T3). Four conditions were used inside microwave furnace (specimens subjected to heat as dry for 30 and 60min. and specimens subjected to heat as wet (water) for 30 and 60 min.), and compared all results with original alloy (AA 2024-T3). Tensile, fatigue, hardness and surface roughness tests were used in this investigation. It is found that hardness of dry conditions is higher than wet conditions and it increases with increasing of time duration inside microwave furnace for dry and wet conditions. Also, tensile strength has the same behavior of hardness, but it increases with decreasing

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Engineering
Effect of Electrical Discharge Machining and Shot Blast Peening Parameters on Fatigue Life of AISI D2 Die Steel
...Show More Authors

The present paper deals with studying the effect of electrical discharge machining (EDM) and shot blast peening parameters on work piece fatigue lives using copper and graphite electrodes. Response surface methodology (RSM) and the design of experiment (DOE) were used to plan and design the experimental work matrices for two EDM groups of experiments using kerosene dielectric alone, while the second was treated by the shot blast peening processes after EDM machining. To verify the experimental results, the analysis of variance (ANOVA) was used to predict the EDM models for high carbon high chromium AISI D2 die steel. The work piece fatigue lives in terms of safety factors after EDM models were developed by FEM using ANSY

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 14 2020
Journal Name
Materials Science Forum
The Cyclic Fatigue Behavior for 6061-T6 Al Alloy Shafts Processed by Laser Shock Peening
...Show More Authors

The optimal combination of aluminum quality, sufficient strength, high stress to weight ratio and clean finish make it a good choice in driveshafts fabrication. This study has been devoted to experimentally investigate the effect of applying laser shock peening (LSP) on the fatigue performance for 6061-T6 aluminum alloy rotary shafts. Q-switched pulsed Nd:YAG laser was used with operating parameters of 500 mJ and 600 mJ pulse energies, 12 ns pulse duration and 10 Hz pulse repetition rate. The LSP is applied at the waist of the prepared samples for the cyclic fatigue test. The results show that applying 500 mJ pulse energy yields a noticeable effect on enhancing the fatigue strength by increasing the required number of cycles to fracture the

... Show More
View Publication Preview PDF
Scopus Crossref