The present work covers the analytical design process of three dimensional (3-D) hip joint prosthesis with numerical fatigue stress analysis. The analytical generation equations describing the different stem constructive parts (ball, neck, tour, cone, lower ball) have been presented to reform the stem model in a mathematical feature. The generated surface has been introduced to FE solver (Ansys version 11) in order to simulate the induced dynamic stresses and investigate the effect of every design parameter (ball radius, angle of neck, radius of neck, neck ratio, main tour radius, and outer tour radius) on the max. equivalent stresses for hip prosthesis made from titanium alloy. The dynamic loading case has been studied to a stumbling case. The load has been applied on the cap tip as a concentrated load distributed on the interface of ball and socket. The results show that the decreasing of max. Fatigue stress by (175) MPa could be obtained by increasing the outer tour radius from (10)mm to (15) mm and that will change the max. Fatigue zone location from the tour section to the neck. The ball radius and neck angle must be as lower as possible to decrease the fatigue stresses. The most dominate parameter to increase the safety factor is the radius of neck.
The wound healing process is incredibly intricate, consisting of a series of cellular activities. Although, this complex process has the potential to degenerate and result in chronic wound problems that are resistant to biological healing mechanisms. Nanoparticles can help to reduce inflammation, promote tissue regeneration, and accelerate wound healing. The proteolytic enzymes are believed to break down proteins and other molecules that can cause inflammation and impede the healing process. Wound was created in vivo using adult mice, and by taking blood samples the hematological parameters were evaluated to detected the effects of bromelain, silver nanoparticles and Br-AgNPs. The results shows an increased in white blood cells WBC, RBC, MC
... Show MoreThis study introduced the effect of using magnetic abrasive finishing method (MAF) for finishing flat surfaces. The results of experiment allow considering the MAF method as a perspective for finishing flat surfaces, forming optimum physical mechanical properties of surfaces layer, removing the defective layers and decreasing the height of micro irregularities. Study the characteristics which permit judgment parameters of surface quality after MAF method then comparative with grinding
In this paper, I highlight the bishops mentioned in the Bible in its sections
(The Old and New Testaments) where these books still retain the remaining remnant of the Bible
Issuing the prophets who preceded the mission of the Prophet Muhammad (peace and blessings of Allaah be upon him) and they must pray
And peace, as those bishops were mentioned in the Book of Formation through the recitation of the psalms
To Habakkuk, Malakhi, and Hajji.
As well as in the New Testament, which we see clearly in the four Angels: Matthew, Luke,
Disco, John.
Then the male lamented what was said of those bishops by expressing the eternal heavenly book (the Qur'an)
Al - Karim) as he focuses on this subject from multiple angles and exp
So far, APT (Advanced Persistent Threats) is a constant concern for information security. Despite that, many approaches have been used in order to detect APT attacks, such as change controlling, sandboxing and network traffic analysis. However, success of 100% couldn’t be achieved. Current studies have illustrated that APTs adopt many complex techniques to evade all detection types. This paper describes and analyzes APT problems by analyzing the most common techniques, tools and pathways used by attackers. In addition, it highlights the weaknesses and strengths of the existing security solutions that have been used since the threat was identified in 2006 until 2019. Furthermore, this research proposes a new framework that can be u
... Show MoreThis work focused on principle of higher order mode excitation using in- line Double Clad Multi-Mode Mach-Zehnder Interferometer (DC-MM-MZI). The DC-MM-MZI was designed with 50 cm etched MMF. The etching length is 5cm. The tenability of this interferometer was studied using opt grating ver.4.2.2 and optiwave
ver. 7 simulator. After removing (25, 35, 45, 55) μm from MMF and immersing this segment of MMF with water bath contained distilled water and ethanol, in addition to, air. Pulsed laser source centered at 1546.7nm ,pulse width 10ns and peak power 1.33mW was propagated via this interferometer Maximum modes were obtained in case of air surrounded media which are 9800 and 25 um removed cladding layer, with peak power 49.800 m