Preferred Language
Articles
/
joe-2175
Laminar Natural Convection in nonrectangular Enclosure with and without Fins
...Show More Authors

In the present work, steady, laminar natural convection in nonrectangular enclosures is analyzed numerically with and without fin. Vertical walls insulated while horizontal walls maintained isothermal at different temperature and the fin was placed on horizontal surface. The length of fin was equal (B/L=0.22, 0.44 and 0.66) and thickness of fin was constant. Various parameters are studied: Rayleigh number (from 104 to 107 ), Prandtl number (0.7), number of fin change from (1-3) and aspect ratio (H/L= 0.15 to 0.5). The problem is formulated in terms of the vorticity-stream function procedure. A numerical solution based on program in Fortran 90 with Tec plot program. The finite difference method is used. Streamlines and isotherms are presented for different values of parameters studied. A Nusselt number correlation is derived by using program (DGA v1.00) and mean Nusselt numbers on hot walls are also calculated at different cases. The results show the mean Nusselt numbers decreases with increasing aspect ratio (H/L).Also, predictions reveal a decrease in heat transfer in the presence of fins. The results of the calculations are compared with the previous works and it showed a good agreement.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 23 2018
Journal Name
International Journal Of Biosciences
Serum and salivary levels of thyroid antibodies (TPO-Ab&Tg-Ab) in the of hypothyroid patients with and without periodontitis
...Show More Authors

Hypothyroidism is the decrease in thyroid hormones production and thyroid gland function. Hashimoto’s thyroiditis is the most common cause of hypothyroidism with production of autoantibodies directed toward autoantigens thyroglobulin (Tg) and thyroid peroxidase (TPO). This study was carried out to determine and compare serum and salivary levels of thyroid antibodies (TPO-Ab and Tg- Ab) in hypothyroid patients (with and without periodontitis) and healthy control; as well as to estimate the possibility to evaluate and measured these antibodies in the saliva as measured in the serum. Serum and saliva samples were collected from sixty hypothyroid patients with age ranged (20-64) years (30 of patients were with periodontitis and 30 without per

... Show More
Publication Date
Tue Jan 01 2019
Journal Name
Ibn Al-haitham Jour.for Pure & Appl.sci.
Study of IL-33 and IL-1R4 in Iraqi Rheumatoid Arthritis Female Patient's with and without Dyslipidemia Prone to Atherosclerosis
...Show More Authors

This study is planned to find relationship between interleukin-33 (IL-33) with its receptor interleukin-1 receptor 4 (IL-1R4), and assurance IL-33/IL-1R4 proportion as biomarker to atherosclerosisin rheumatoid arthritis (RA) Iraqi female’s patients with and without dyslipidemia. This study was attempted at Baghdad Teaching Hospital included 60 female’s patients with RA that were isolated into: 30 patients with dyslipidemia(G2), 30 patients without dyslipidemia(G3) and 30 individuals as control group (G1). Patients were experiencing treatment by methortexiene medication, analyzed by rheumatoid factor (RF) and erythrocyte sedimentation rate (ESR) tests. All patients and control groups age ranged from (30-55) years. The results show an inc

... Show More
Publication Date
Fri Jan 04 2019
Journal Name
Drinking Water Engineering And Science Discussions
Froth Production in Potable Water without Chemicals
...Show More Authors

Abstract. Froth flotation is a well-known solid-liquid separation technique. Hydrophobicity is the main driving force for such processes. Hydrophobic solids attach to air bubbles and rise up while hydrophilic or less hydrophobic species settle down. Froth can be produced with chemical frothers such as alcohols and polyglycols. However, the use of chemicals limits the use of this separation method in applications such as drinking water, food, and pharmaceutical industries. Therefore, developing a technique that produces froth without adding any chemicals would be useful to such industries. This work demonstrates that with suitable operating parameters a 27 cm froth height can be obtained in a 20 cm diameter column by using an air

... Show More
View Publication
Crossref
Publication Date
Wed Sep 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Free Convection in an Inclined Concentric Annular Square Cavities Filled With Porous Medium and Heated By Non-Uniform Temperature
...Show More Authors

A numerical study of the two-dimensional steady free convection flow in an inclined annulus between two concentric square cavities filled with a porous medium is presented in this paper for the case when the side outer walls are kept with differentially heated temperature while the horizontal outer walls and the inner walls are insulated. The heated wall is assumed to have spatial sinusoidal temperature variation about a constant mean value. The Darcy model is used and the fluid is assumed to be a standard Boussinesq fluid. For the Cartesian coordinate system, the governing equations which were used in stream function form are discretized by using the finite difference method with successive under – relaxation method (SUR) and are solv

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Influence of Caries Infiltrant Combined with and without Conventional Adhesives on Sealing of Sound Enamel (In Vitro Study)
...Show More Authors

Background: The formation of white spot lesions around fixed orthodontic attachments is a common complication during and after fixed orthodontic treatment, which hinders the result of a successfully completed orthodontic treatment. The aim of the study was to assess the effectiveness of the Caries Infiltrant (ICON®) on prevention of caries on the smooth enamel surface when applied alone or combined with conventional adhesives. Materials and methods: Seventy eight human premolar enamel discs were randomly assigned to six groups (n=13). The discs were etched and treated with resins of different monomer content forming the following groups: (1)Untreated etched samples served as the negative control, (2) ICON® (DMG), (3) Adper™ S

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Mixed Convection Heat Transfer in a Vertical Saturated Concentric Annulus Packed with a Metallic Porous Media
...Show More Authors

Mixed convection heat transfer in a vertical concentric annulus packed with a metallic porous media and heated at a constant heat flux is experimentally investigated with water as the working fluid. A series of experiments have been carried out with a Rayleigh number range from Ra=122418.92 to 372579.31 and Reynolds number that based on the particles diameter of Red=14.62, 19.48 and 24.36. Under steady state condition, the measured data were collected and analyzed. Results show that the wall surface temperatures are affected by the imposed heat flux variation and Reynolds number variation. The variation of the local heat transfer coefficient and the mean Nusselt number are presented and analyzed. An empirical

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mixed convection in an Horizontal Rectangular Duct Including interior Circular Core with Time periodic Boundary Condition
...Show More Authors

Numerical Investigation was done for steady state laminar mixed convection and thermally and hydrodynamic fully developed flow through horizontal rectangular duct including circular core with two cases of time periodic boundary condition, first case  on the rectangular wall while keeping core wall constant and other on both the rectangular duct and core walls. The used governing equations are continuity momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function and the Body Fitted Coordinates (B.F.C.) methods. The Finite Difference approach with the Line Successive Over Relaxation (LSOR) method is used to obtain all the computational results the (B.F.C.) method is used to generate th

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 09 2021
Journal Name
Nanomaterials
Investigation of Heat Transfer Enhancement in a Triple Tube Latent Heat Storage System Using Circular Fins with Inline and Staggered Arrangements
...Show More Authors

Inherent fluctuations in the availability of energy from renewables, particularly solar, remain a substantial impediment to their widespread deployment worldwide. Employing phase-change materials (PCMs) as media, saving energy for later consumption, offers a promising solution for overcoming the problem. However, the heat conductivities of most PCMs are limited, which severely limits the energy storage potential of these materials. This study suggests employing circular fins with staggered distribution to achieve improved thermal response rates of PCM in a vertical triple-tube heat exchanger involving two opposite flow streams of the heat-transfer fluid (HTF). Since heat diffusion is not the same at various portions of the PCM unit,

... Show More
View Publication Preview PDF
Scopus (50)
Crossref (48)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Brazilian Dental Science
Assessing the level and diagnostic accuracy of osteopontin and oral health status in periodontitis patients with/without Type-2 Diabetes Mellitus
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Brazilian Dental Science
Assessing the level and diagnostic accuracy of osteopontin and oral health status in periodontitis patients with/without Type-2 Diabetes Mellitus
...Show More Authors

View Publication
Scopus (4)
Crossref (1)
Scopus Crossref