Preferred Language
Articles
/
joe-2160
Effect of Fire Flame (High Temperature) on the Behaviour of Axially loaded Reinforced SCC Short Columns
...Show More Authors

Experimental research was carried out to investigate the effect of fire flame (high temperature) on specimens of short columns manufactured using SCC (Self compacted concrete). To simulate the real practical fire disasters, the specimens were exposed to high
temperature flame, using furnace manufactured for this purpose. The column specimens were cooled in two ways. In the first the specimens were left in the air and suddenly cooled using water, after that the specimens were loaded to study the effect of degree of
temperature, steel reinforcement ratio and cooling rate, on the load carrying capacity of the reinforced concrete column specimens. The results will be compared with behaviour of columns without burning (control specimens). The results showed that, the ultimate load capacity of columns exposed to fire decreases with increasing the fire flame temperature. At burning temperature 300 Co , 500 Co and 700 Co , the average residual ultimate load capacity for gradually cooled specimens were 91%, 81% and 71% respectively. By increasing the ratio of longitudinal reinforcement 44% , the maximum improvement in the ultimate load capacity was 24% and 17% for the gradually and sudden cooling respectively at Co 500 . For the same longitudinal reinforcement ratio and fire burning temperature, the ultimate capacity for the sudden cooling specimens was less than that of gradually cooled specimens by about 10%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction
Calculating the Real Need for Fire Brigade Stations in Al-Samawah City
...Show More Authors

The location of fire brigade stations and equipment has a significant impact on the efficacy and efficiency of fire brigade department services. The challenge addressed by this study was that the fire brigade department required a consistent and repeatable technique to assess the response capabilities and safeguarding levels offered as the city of Samawah/Iraq grew and changed. Evaluating the locations of the current fire brigade stations in the city of Samawah is the aspect addressed by the research to determine the accuracy and validity of the locations of these stations by the competent authorities and their suitability to the area of the city’s neighborhoods and its residents. The Iraqi Ministry of Housing, Construction, Municipalitie

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jan 01 2012
Journal Name
International Journal Of Contemporary Mathematical Sciences
Pre-Topology Generated by the Short Path Problems
...Show More Authors

Let G be a graph, each edge e of which is given a weight w(e). The shortest path problem is a path of minimum weight connecting two specified vertices a and b, and from it we have a pre-topology. Furthermore, we study the restriction and separators in pre-topology generated by the shortest path problems. Finally, we study the rate of liaison in pre-topology between two subgraphs. It is formally shown that the new distance measure is a metric

Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Almustansyria Journal Of Arts
Presupposition in Poe’s Short story “The Black Cat
...Show More Authors

The notion of presupposition has been tackled by many linguists. They have found that the term ―presupposition” is being used in two different senses in the literature: semantic and pragmatic. As for semantic sense, Geurts (1999) has isolated some constrictions as sources of presupposition by making lists of presupposition triggers. Concerning the pragmatic sense Kennan (1971:89) uses the term pragmatic presupposition to refer to a class of pragmatic inferences which are, in fact, the relation between a speaker and the appropriateness of a sentence in the context. In spite of the fact that there are many researches that have been done in the field of presupposition but few of them in the field of short stories up to the researcher's kno

... Show More
Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
E3s Web Of Conferences 318, 03002 (2021)
A Comparative Study on Behavior of RC Columns Strengthened by CFRP and Steel Jacket
...Show More Authors

This paper studies the behavior of axially loaded RC columns which are confined with carbon fiber reinforced polymers’ sheet (CFRP) and steel jackets (SJ). The study is based on twelve axially loaded RC columns tested up to failure. It is divided into three schemes based on its strengthening type; each scheme has four columns. The main parameters in this study were the compressive strength of the concrete and steel reinforcement ratio. Furthermore, the results of the experimental test showed a substantial enhancement in the column's load-carrying capacity. When compared to the original columns, the CFRP sheet had a significant effect on improving the ductility of the column by increasing the axial deformation by about 59.2 to 95.7

... Show More
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Effect of sulfuric acid solution on thermal conductivity and impact strength of epoxy resin reinforced by silicon dioxide powder
...Show More Authors

In this search, Ep/SiO2 at (3, 6, 9, 12 %) composites is prepared by hand Lay-up method, to measure the change in the thermal conductivity and Impact Strength of epoxy resin before and after immersion in H2SO4 Solution with a 0.3N for 10 days. The results before immersion decreases with the increase of the weight ratios of the reinforcement material (SiO2), It changed from (82.6×10-2 to 38.7×10-2 W/m.°C) with change weight ratios from (3 to 12) % respectively, but after immersion time in the chemical solution where it was (65.6×10-2 W/m.°C) at the weight ratios (6 %) and became (46.6 × 10-2 W/m.°C) after immersion in sulfuric acid. The results of the Impact strength decreased by increasing the percentage weight ratio, it changed f

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Effect of water absorption on some mechanical and physical properties of epoxy/polyurethane blend reinforced with nano silica powder
...Show More Authors

The aim of this work is to evaluate some mechanical and physical
properties (i.e. the impact strength, hardness, flexural strength,
thermal conductivity and diffusion coefficient) of
(epoxy/polyurethane) blend reinforced with nano silica powder (2%
wt.). Hand lay-up technique was used to manufacture the composite
and a magnetic stirrer for blending the components. Results showed
that water had affected the bending flexural strength and hardness,
while impact strength increased and thermal conductivity decreased.
In addition to the above mentioned tests, the diffusion coefficient
was calculated using Fick’s 2nd law.

View Publication
Crossref (3)
Crossref
Publication Date
Mon Jan 08 2024
Journal Name
Al-academy
Aesthetics of experimentation In short television films
...Show More Authors

Experimentation Multi effective and fertile grew human desire to discover new ways to express beauty in artwork .And dabble term experimentation in the performing arts and arts architecture, cinema and television in the test forms and interest in the visual effects and movements seek to establish and beauty and schools of thought in literature and art. This study aims to identify

View Publication Preview PDF
Publication Date
Thu Jan 10 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Influence of Accelerated Curing on Fiber Reinforced Concrete
...Show More Authors

The adopted accelerated curing methods in the experimental work are 55ºC and 82ºC according to British standard methods. The concrete mix with the characteristics compressive strength of 35MPa is design according to the ACI 211.1, the mix proportion is (1:2.65:3.82) for cement, fine and coarse aggregate, respectively. The concrete reinforced with different volume fraction (0.25, 0.5 and 0.75)% of glass, carbon and polypropylene fibers. The experimental results showed that the accelerated curing method using 82ºC gives a compressive strength higher than 55ºC method for all concrete mixes. In addition, the fiber reinforced concrete with 0.75% gives the maximum compressive strength, flexural and splitting tensile strength for all types of

... Show More
View Publication
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Experimental Study of a Biomechanical Behaviour of Rat Patellar Tendon
...Show More Authors

Tendon is important structure of the human body, since it can sustain tensile loading. The primary function of this tissue is to stabilize the joints they attached to it during daily activities. As well as, tendon has viscoelastic properties that can determine their response to loading and restrict the potential of injuries. One of the major points that this paper works with is the study of the biomechanical behaviour of tendon in response to tensile loading to describe their biological behaviour. Also, conclude the mathematical expression that may illustrate the tendon behaviour. All of the experiments were made in Physiology laboratories / Medical College/ Al- Nahrain University on ten rats "Rattus Norvegicus" of [108- 360] gm weight f

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 10 2026
Journal Name
Journal Of Composites Science
The Structural Behavior of Encased Composite Columns Under Biaxial Loading Conditions
...Show More Authors

This study presents a theoretical investigation of encased composite columns under biaxial loading. The EUROCODE 4 theoretical model for generating the uniaxial interaction diagram was developed and used to meet biaxial requirements. The primary objective was to evaluate how internal steel ratios and configurations and concrete compressive strength influence the axial and biaxial flexural performance of the composite column. Ten models were analyzed, and the results were validated against previous experimental and analytical data. The results indicate that internal reinforcement is the primary driver of stiffness. Changing from an I-section to equivalent reinforcing bars or four steel angles significantly improves the y-axis stiffne

... Show More
View Publication
Crossref