In this work, the effect of variation of semi-angle of the conical part on the vibration characteristics of cylindrical-conical coupled structure is investigated. The shell is made of polyester resin reinforced by continuous E-glass fibers. The case is analyzed experimentally and numerically for orthotropic shell structures. The experimental program is conducted by exciting the fabricated structure by an impact hammer and monitoring the response using an attached accelerometer for different semi-angles of the conical part.
Software named SIGVIEW is used to perform the signal processing on the acquired signal in order to measure the natural frequencies and the corresponding mode shapes. The numerical investigation is achieved using ANSYS (Finite Element software) which was verified by the experimental results. Good agreement is achieved when comparing the experimental and numerical results. The maximum deviation in results was found to be (5.9%). The maximum relative nodal rotational and translational amplitudes associated with the
first normal mode of the orthotropic and isotropic shells are noted for the structure of semi-angle of cone of 45o .
Background: Stress urinary incontinence is a frequent urological disease in women; it has a great influence on an individual’s wellbeing and places a significant economic strain on any health service. The placement of urodynamic diagnostic tests in the evaluation route is an important clinical research concern in this field.
Objective: to find out whether the duration of stress urinary incontinence is associated with the finding of bladder outlet obstruction in urodynamic study or not.
Subjects and Methods: A descriptive study. With enrolled female patients had symptomatic Stress urinary incontinence as their primary complain. All the included patients w
... Show MoreBackground: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in
... Show MoreBackground: to evaluate the effect of different dentifrices on the surface roughness of two composite resins (nanofilled-based and nanoceramic – based composite resins). Materials and methods: Forty specimens (diameter 12 mm and height of 2mm) prepared from different composite resin materials: Z350 (nanofilled composite, and Ceram-X (nanoceramic) .they were subjected to brushing simulation equivalent to the period of 1 year. The groups assessed were a control group brushed with distilled water (G1), Opalescence whitening toothpasteR (G2), Colgate sensitive pro-relief (G3) and Biomed Charcoal Toothpaste (G4). The initial and final roughness of each group was tested by surface roughness tester. The results were statistically analyzed using
... Show MoreIn this research the Inter-Particle Expectation Values have been studied for atomics Helium (He) and Beryllium (Be) also for He-like ions, Be-like ions (Li-1, B+1? Li+1, Be+2, B+3) by using Hartree-Fock wave functions, We compared the results to some ions which have the same atomic number from each group with atomic number, We compared the results with published calculations to the last studied .
An experimental investigation has been made to study the influence of using v-corrugated aluminum fin on heat transfer coefficient and heat dissipation in a heat sink. The geometry of fin is changed to investigate their performance. 27 circular perforations with 1 cm diameter were made. The holes designed into two ways, inline arrangement and staggered in the corrugated edges arrangement. The experiments were done in enclosure space under natural convection. Three different voltages supplied to the heat sink to study their effects on the fins performance. All the studied cases are compared with v-corrugated smooth solid fin. Each experiment was repeated two times to reduce the error and the data recorded after reaching t
... Show MoreAccording to the famous saying of the medieval physician Paracelsus, "There is no substance without poison. Only the dose determines the extent of the toxic effect." Here, the effect of monosodium glutamate (MSG) on human health and the risks to the health of its frequent use in the short term was addressed and the long term was evaluated according to the studies of several researchers specializing in this regard. Monosodium glutamate (MSG) is known as one of the most popular food additives that classified as a flavor enhancer. Parts of the evidence were reviewed from the literature explaining its effect on immune system cells in addition to metabolic disorders by exposing individuals to obesity and what is known as metabolic syndrome, as w
... Show MoreThis work presents an experimental study of heat transfer and flow of distilled water and metal oxide nanofluid Fe3O4-distilled water at concentrations of (φ = 0.3, 0.6, 0.9 %) by volume in a horizontal pipe with constant magnetic field. All the tests are carried out with Reynolds number range (2900-9820) and uniform heat flux (11262-19562 W/m2). The results show that, the nanofluid concentration and magnetic intensity increase, the Nusselt number increases. The maximum enhancement in Nusselt number with magnetic nanofluid is (5.4 %, 26.4 %, 42.7 %) for volume concentration (0.3, 0.6, 0.9 %) respectively. The enhancement is maximized with magnetic intensity (0.1, 0.2, 0.3 tesla) respectively to (43.9, 44
... Show MoreIn this research, some robust non-parametric methods were used to estimate the semi-parametric regression model, and then these methods were compared using the MSE comparison criterion, different sample sizes, levels of variance, pollution rates, and three different models were used. These methods are S-LLS S-Estimation -local smoothing, (M-LLS)M- Estimation -local smoothing, (S-NW) S-Estimation-NadaryaWatson Smoothing, and (M-NW) M-Estimation-Nadarya-Watson Smoothing.
The results in the first model proved that the (S-LLS) method was the best in the case of large sample sizes, and small sample sizes showed that the
... Show More