Preferred Language
Articles
/
joe-2117
Assessment of Water Quality Index and Water Suitability of the Tigris River for drinking water within Baghdad City, Iraq
...Show More Authors

In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, water quality management and decision making. The application of Water Quality Index
(WQI) with sixteen physicochemical water quality parameters was performed to evaluate the quality of Tigris River water for drinking usage. This was done by subjecting the water samples collected from eight stations in Baghdad city during the period 2004-2010 to comprehensive physicochemical analysis. The sixteen physicochemical parameters included: Turbidity, Alkalinity (TA), Total Hardness (TH), Calcium (Ca), Magnesium (Mg), Iron (Fe), pH value, Electrical Conductivity (EC), Sulphate (SO4 -2), Chloride (Cl-), Total Solids (TS), Total Suspended Solids (TSS), Nitrite (NO2-), Nitrate (NO3-), Ammonia (NH3), and Orthophosphate (PO4-3). The average annual overall WQI was 224.32 through the study period. The high value of average annual overall WQI obtained is a result of the high concentrations of turbidity, total hardness, electrical conductivity, and total solids which can be attributed to the various human activities taking place at the river banks. From this analysis the quality of the Tigris River is classified as "very poor quality" ranging poor water at the river upstream near Al-Karhk WTP and unsuitable for drinking at the river downstream near Al-Wahda WTP and would need further treatment. The present study demonstrated the application of WQI in estimating and understanding the water quality of Tigris River. WQI appears to be promising in water quality management and a valuable tool in categorizing pollution sources in surface waters.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
International Journal Of Intelligent Systems And Applications In Engineering
Artificial Intelligence Based Statistical Process Control for Monitoring and Quality Control of Water Resources: A Complete Digital Solution
...Show More Authors

Scopus (3)
Scopus
Publication Date
Thu Aug 01 2024
Journal Name
Iop Conference Series: Earth And Environmental Science
Impact of Using Subsurface Water Retention Technology on Improving Water Use Efficiency of Furrow Irrigation System
...Show More Authors
Abstract<p>Evaluation was carried out on the existing furrow irrigation system located in an open agricultural field within Hor Rajabh Township, south of Baghdad, Iraq (latitude: 33°09’ N, longitude: 44°24’ E). Two plots were chosen for comparison: treatment plot T1, which used subsurface water retention technology (SWRT) with a furrow irrigation system. While the treatment plot T2 was done by using a furrow irrigation procedure without SWRT. A comparison between the two treatment plots was carried out to study the efficiency of the applied water on crop yield. In terms of agricultural productivity and water use efficiency, plot T1 outperformed plot T2, according to the study’s final fin</p> ... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Iraqi Journal Of Physics
Preparation of Silicon Nanowires Photocathode for Photoelectrochemical Water Splitting
...Show More Authors

A metal-assisted chemical etching process employing p-type silicon wafers with varied etching durations is used to produce silicon nanowires. Silver nanoparticles prepared by chemical deposition are utilized as a catalyst in the formation of silicon nanowires. Images from field emission scanning electron microscopy confirmed that the diameter of SiNWs grows when the etching duration is increased. The photoelectrochemical cell's characteristics were investigated using p-type silicon nanowires as working electrodes. Linear sweep voltammetry (J-V) measurements on p-SiNWs confirmed that photocurrent density rose from 0.20 mA cm-2 to 0.92 mA cm-2 as the etching duration of prepared SiNWs increased from 15 to 30 min. The

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Evaluating the Performance of Sharq Dijila Water Treatment Plant
...Show More Authors

The study aims mainly to evaluate the performance of Sharq Dijila water treatment plant in removing turbidity for the period of 1-4-2001 to 31-3-2004. Daily data for turbidity of raw, clarified, filtered, and supplied water were analyzed. The results of the study showed that there is a wide variation in turbidity levels of raw water fluctuating between 10-1000 NTU with mean value of 41.3 NTU. Turbidity values of the clarified water varied between 1.4-77 NTU. Based on the turbidity value of 10 NTU and 20 NTU (the design maximum turbidity) the readings gave an acceptable percentage of 32.4% and 86% respectively. The turbidity of filtered water ranged between 0.2-4.5 NTU which are completely in compliance with Iraqi and WHO standards. In ac

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 11 2019
Journal Name
Journal Of The College Of Education For Women
The South Baghdad Electrical Station and its Environmental Impact on the Tigris River
...Show More Authors

The South Baghdad electrical station located on the eastern bank of the Tigris River south of Baghdad city was selected within the municipality of Karrada between  two  latitude ( 3315 , 33 0  18 )North  and  longitude ( 44 0  27 , 44 030 ) East . The purpose of the study is to determine the contribution of the station to the effect of pollution of the Tigris water by taking water samples at the station site and two sites, one before and the other after the station, distributed over time periods of three months between each sample of water and the beginning of August and November Shabat and Mayar and analyzed water samples physically, chemically and biologic

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 26 2013
Journal Name
Environmental Geochemistry And Health
Assessment of sulfurous springs in the west of Iraq for balneotherapy, drinking, irrigation and aquaculture purposes
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Tue Feb 22 2022
Journal Name
Watre
Subsurface Flow Phytoremediation Using Barley Plants for Water Recovery from Kerosene-Contaminated Water: Effect of Kerosene Concentration and Removal Kinetics
...Show More Authors

A phytoremediation experiment was carried out with kerosene as a model for total petroleum hydrocarbons. A constructed wetland of barley was exposed to kerosene pollutants at varying concentrations (1, 2, and 3% v/v) in a subsurface flow (SSF) system. After a period of 42 days of exposure, it was found that the average ability to eliminate kerosene ranged from 56.5% to 61.2%, with the highest removal obtained at a kerosene concentration of 1% v/v. The analysis of kerosene at varying initial concentrations allowed the kinetics of kerosene to be fitted with the Grau model, which was closer than that with the zero order, first order, or second order kinetic models. The experimental study showed that the barley plant designed in a subsu

... Show More
Crossref (10)
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
Electrocoagulation for Treatment of Simulated Blowdown Water Of Cooling Tower
...Show More Authors

This study investigates the results of electrocoagulation (EC) using aluminum (Al) electrodes as anode and stainless steel (grade 316) as a cathode for removing silica, calcium, and magnesium ions from simulated cooling tower blowdown waters. The simulated water contains (50 mg/l silica, 508 mg/l calcium, and 292 mg/l magnesium). The influence of different experimental parameters, such as current density (0.5, 1, and 2 mA/cm2), initial pH(5,7, and 10), the temperature of the simulated solution(250C and 35 0C), and electrolysis time was studied. The highest removal efficiency of 80.183%, 99.21%, and 98.06% for calcium, silica, and magnesium ions, respectively, were obtained at a current de

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Iraqi Journal Of Applied Physics
Fabrication of PAN:Cellulose Membrane for Oil/Water Separation
...Show More Authors

In this study, we fabricated nanofiltration membranes using the electrospinning technique, employing pure PAN and a mixed matrix of PAN/HPMC. The PAN nanofibrous membranes with a concentration of 13wt% were prepared and blended with different concentrations of HPMC in the solvent N, N-Dimethylformamide (DMF). We conducted a comprehensive analysis of these membranes' surface morphology, chemical composition, wettability, and porosity and compared the results. The findings indicated that the inclusion of HPMC in the PAN membranes led to a reduction in surface porosity and fiber size. The contact angle decreased, indicating increased surface hydrophilicity, which can enhance flux and reduce fouling tendencies. Subsequently, we evaluated the e

... Show More
Scopus
Publication Date
Fri Apr 01 2022
Journal Name
Desalination And Water Treatment
MgCl2 and MgSO4 as draw agents in forward osmosis process for East Baghdad oilfield produced water treatment
...Show More Authors

This study investigated a novel application of forward osmosis using different types of draw solutions for oilfield produced water treatment from the East Baghdad oilfield affiliated to the Midland Oil Company (Iraq). Magnesium chloride (MgCl2) and magnesium sulfate (MgSO4) were used as draw solutions in forward osmosis process to evaluate their effectiveness. Experiments were conducted in a laboratory scale forward osmosis system with cellulose triacetate hollow fiber membrane. In this work, sodium chloride solution was used as a feed solution with a concentration of 76 g/L (same concentration as the East Baghdad oilfield produced water) and the applied external pressure on the feed solution side was 2 bar. The impact of draw solution (DS)

... Show More
View Publication Preview PDF