In this paper thermo-hydrodynamic characteristics were investigated experimentally for a new type shell-helical coiled tube heat exchanger used as a storage tank of closed loop solar water heater system. Triple concentric helical coils were made of copper tubes of (12.5mm OD and 10mm ID) with coils diameter of (207, 152.2, 97mm) for outer, middle and inner coils respectively. The experiments were carried out during a clear sky days of (March and April 2012). The parameters studied in this work are: history of average temperature of shell side of the storage tank, collector heat gain, heat rejected from coils to shell side of the storage tank, collector efficiency, thermal effectiveness of the heat exchanger (storage tank), and pressure drop. These parameters were studied at four different circulating mass flow rates of (1.8, 3, 6, 9 l/min) and for two consuming modes of supply water namely no withdrawal, and continuous withdrawal of (1 l/min). The results show that stratification temperature in the storage tank is increased for no withdrawal compared with water withdrawal, also the shell side average temperature increases with increased solar time. Collector efficiency is increased with increasing circulation flow rates, also increases with water withdrawn from storage tank. The pressure drop decreases with the increase of solar radiation .
Praise be to God, Lord of the worlds, and prayers and peace be upon our master and beloved Muhammad, the wise guide and great teacher, the guide to a straight path, the one sent as a mercy to the worlds, and upon his good and chosen family, his chosen companions, the working scholars, and those who follow them in righteousness until the Day of Judgment.
And after:
One of the important controversial topics shared between the sciences of the Noble Hadith and the Fundamentals of God is the issue of the innovator in terms of accepting and rejecting his narration and testimony, and the difference in it leads to disagreement in many branches of jurisprudence that were based on texts narrated by innovated narrators or those accu
... Show MoreThis research aims at studying and analyzing the creative research thinking of the educational staffs in private universities and colleges, and also the role of incentives, in its materialistic and moral sides in the development of such thinking and the pack of restraints which cause decline in interest level of the scientificresearch, and its weak role in the development of universities in Iraq, despite the interest of the Ministry of Higher Education and Scientific Research in Iraq in scientific research as part ofits academic and humanitarian targets.Based on study and analysis, and the using if some of statistical methods such as the Alpha Chronobaghcoefficient and the (T. Test)(F. Test),the research reached a number of conclusions.
... Show MoreEMS in accordance with ISO 14001: 2015 is considered an entry point to reduce environmental impacts, especially the effects resulting from the oil industry, which is the main source of environmental pollution and waste of natural resources, since the second revision of the standard took place in September 2015. The problem of the research was manifested in the weakness in understanding the correct guidelines that must be followed in order to obtain and maintain the standard. The purpose of this research was to give a general picture of what is behind ISO14001:2015 and how it is possible to create a comprehensive base for understanding its application by seeking the gap between the actually achieved reality, standards requirements
... Show MoreThe study aims mainly to evaluate the performance of Sharq Dijila water treatment plant in removing turbidity for the period of 1-4-2001 to 31-3-2004. Daily data for turbidity of raw, clarified, filtered, and supplied water were analyzed. The results of the study showed that there is a wide variation in turbidity levels of raw water fluctuating between 10-1000 NTU with mean value of 41.3 NTU. Turbidity values of the clarified water varied between 1.4-77 NTU. Based on the turbidity value of 10 NTU and 20 NTU (the design maximum turbidity) the readings gave an acceptable percentage of 32.4% and 86% respectively. The turbidity of filtered water ranged between 0.2-4.5 NTU which are completely in compliance with Iraqi and WHO standards. In ac
... Show MoreAn experimental study was conducted on pressure drop of water flow through vertical cylindrical packed beds in turbulent region and the influence of the operating parameters on its behavior. The bed packing was made of spherical and non-spherical particles (spheres, Rasching rings and intalox saddle) with aspect ratio range 3.46 D/dp 8.486 obtaining bed porosities 0.396 0.84 and Reynolds number 1217 21758. The system is consisted of 5 cm inside diameter Perspex column, 50 cm long; distilled water was pumped through the bed with flow rate 875, 1000, 1125, 1250,1375 and 1500 l/h and inlet water temperature 20, 30, 40 and 50 ˚C. The packed bed system was monitored by using LabVIEW program, were the result
... Show MoreThe tax system, like any other system, as a set of elements and parts that complement each other and are interrelated and interact to achieve specific goals, and is a natural reflection of the economic, social and political conditions prevailing in society, and therefore the objectives of tax policy formulated in line with the objectives of economic policy in general, which means that any change in economic policy clearly affects fiscal policy measures and fiscal policy in particular.
The problem of searching for the impact of foreign direct investment in the Iraqi tax system was focused on the study the of foreign direct investment and therole played in developing and improving the economic reality and its implicatio
... Show MoreHistory matching is a significant stage in reservoir modeling for evaluating past reservoir performance and predicting future behavior. This paper is primarily focused on the calibration of the dynamic reservoir model for the Meshrif formation, which is the main reservoir in the Garraf oilfield. A full-field reservoir model with 110 producing wells is constructed using a comprehensive dataset that includes geological, pressure-volume-temperature (PVT), and rock property information. The resulting 3D geologic model provides detailed information on water saturation, permeability, porosity, and net thickness to gross thickness for each grid cell, and forms the basis for constructing the dynamic reservoir model. The dynamic reservoir mo
... Show MoreLow-temperature stratification, high-volumetric storage capacity, and less-complicated material processing make phase-changing materials (PCMs) very suitable candidates for solar energy storage applications. However, their poor heat diffusivities and suboptimal containment designs severely limit their decent storage capabilities. In these systems, the arrangement of tubes conveying the heat transport fluid (HTF) plays a crucial role in heat communication between the PCM and HTF during phase transition. This study investigates a helical coil tube-and-shell thermal storage system integrated with a novel central return tube to enhance heat transfer effectiveness. Three-dimensional computational fluid dynamics simulations compare the proposed d
... Show More