Preferred Language
Articles
/
joe-209
Accuracy Evaluation of Digital Elevation Model Created Using Handheld Global Positioning System Receivers
...Show More Authors

This study aims to assess the accuracy of digital elevation model (DEM) created with utilization of handheld Global Positioning System (GPS) and comparing with Advanced Spaceborne Thermal Emission and Reflection Radiometer Global Digital Elevation Model (ASTER GDEM), version 2. It is known that the quality of the DEM is affected by both of accuracy of elevation at each pixel (absolute accuracy) and accuracy of presented morphology (relative accuracy). The University of Baghdad, Al Jadriya campus was selected as a study area to create and analysis the resulting DEM. Additionally, Geographic Information System (GIS) was used to visualize, analyses and interpolate GPS track points (elevation data) of the study area. In this research, three additional DEMs were created using 60%, 30% and 15% of the all GPS track points to deduce the effect of the number of the included points on the accuracy of the resulting DEM. The study findings show a high resolution for the resulting DEM less than 5m when taking into consideration all GPS tracking points that observed in this research. Moreover, the resulting DEM has relative accuracy better than absolute accuracy and reaches to around 2m. By comparing with ground control points (reference points), the quality of handheld GPS DEM shows considerable improvement better than ASTER GDEM. Thus, this study indicates to improve the accuracy level of handheld GPS DEM by about 40% with increasing the observed number of GPS track points to twice.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Developing Arabic License Plate Recognition System Using Artificial Neural Network and Canny Edge Detection
...Show More Authors

            In recent years, there has been expanding development in the vehicular part and the number of vehicles moving on the roads in all the sections of the country. Arabic vehicle number plate identification based on image processing is a dynamic area of this work; this technique is used for security purposes such as tracking of stolen cars and access control to restricted areas. The License Plate Recognition System (LPRS) exploits a digital camera to capture vehicle plate numbers is used as input to the proposed recognition system. Basically, the proposed system consists of three phases, vehicle license plate localization, character segmentation, and character recognition, the

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Jun 01 2017
Journal Name
International Journal Of Heat And Mass Transfer
Melting enhancement in triplex-tube latent thermal energy storage system using nanoparticles-fins combination
...Show More Authors

View Publication
Scopus (205)
Crossref (198)
Scopus Clarivate Crossref
Publication Date
Tue Dec 05 2023
Journal Name
Baghdad Science Journal
A Novel System for Confidential Medical Data Storage Using Chaskey Encryption and Blockchain Technology
...Show More Authors

Secure storage of confidential medical information is critical to healthcare organizations seeking to protect patient's privacy and comply with regulatory requirements. This paper presents a new scheme for secure storage of medical data using Chaskey cryptography and blockchain technology. The system uses Chaskey encryption to ensure integrity and confidentiality of medical data, blockchain technology to provide a scalable and decentralized storage solution. The system also uses Bflow segmentation and vertical segmentation technologies to enhance scalability and manage the stored data. In addition, the system uses smart contracts to enforce access control policies and other security measures. The description of the system detailing and p

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Wed Jun 01 2011
Journal Name
Journal Of Economics And Administrative Sciences
Methods of using the periodic chart in the case of the missing values of the stable AR model (2)
...Show More Authors

In this study, we investigate the behavior of the estimated spectral density function of stationary time series in the case of missing values, which are generated by the second order Autoregressive (AR (2)) model, when the error term for the AR(2) model has many of continuous distributions. The Classical and Lomb periodograms used to study the behavior of the estimated spectral density function by using  the simulation.

 

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Calculate the sum of squares for parts (vehicles) SSE in 2n global trials with total integration In a suggested manne
...Show More Authors
In order to serve the field of knowledge in the field of design and analysis of experiments by adopting formulas and methods that are easy and simple in arithmetic work, especially in experiments that require many calculations for squares, including tests of type
... Show More
View Publication
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Iraqi Journal Of Agricultural Sciences
Effect of cultural media and nutrient solution on quality and production of cucumber by using hydroponic system.
...Show More Authors

Publication Date
Sun Dec 07 2008
Journal Name
Baghdad Science Journal
Developing of Bacterial Mutagenic Assay System for Detection of Environmental and Food MutagensV – Using Anticancer Drug Cyclophosphamide
...Show More Authors

G-system composed of three isolates G3 ( Bacillus),G12 ( Arthrobacter )and G27 ( Brevibacterium) was used to detect the mutagenicity of the anticancer drug, cyclophosphamide (CP) under conditions similar to that used for standard mutagen, Nitrosoguanidine (NTG). The CP effected the survival fraction of isolates after treatment for 15 mins using gradual increasing concentrations, but at less extent comparing to NTG. The mutagenic effect of CP was at higher level than that of NTG when using streptomycin as a genetic marker, but the situation was reversed when using rifampicin resistant as a report marker. The latter effect appeared upon recording the mutagen efficiency (ie., number of induced mutants/microgram of mutagen). Measuring the R

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 12 2023
Journal Name
Iraqi Postgraduate Medical Journal
The Accuracy of Electrocardiographic Criteria for Predicting Left Ventricular Hypertrophy in adult Patients with Systemic Hypertension
...Show More Authors

ABSTRACT: BACKGROUND: Left ventricular hypertrophy is a significant risk factor for cardiovascular complications such as ischemic heart disease, heart failure, sudden death, atrial fibrillation, and stroke. A proper non-expensive tool is required for detection of this pathology. Different electrocardiographic (ECG) criteria were investigated; however, the results were conflicting regarding the accuracy of these criteria. OBJECTIVE: To assess the accuracy of three electrocardiographic criteria in diagnosis of left ventricular hypertrophy in adult patients with hypertension using echocardiography as a reference test. PATIENTS AND METHODS: This is a hospital-based cross sectional observational study which included 340 adult patients with a his

... Show More
Preview PDF
Publication Date
Sat Jun 03 2017
Journal Name
Journal Of Diagnostic Medical Sonography
The Diagnostic Accuracy of Sonography, With Graded Compression to Image Acute Appendicitis Compared to Histopathologic Results
...Show More Authors

Acute appendicitis is the most common surgical abdominal emergency. Its clinical diagnosis remains a challenge to surgeons, so different imaging options were introduced to improve diagnostic accuracy. Among these imaging modality choices, diagnostic medical sonography (DMS) is a simple, easily available, and cost effective clinical tool. The purpose of this study was to assess the accuracy of DMS, in the diagnosis of acute appendicitis compared to the histopathology report, as a gold standard. Between May 2015 and May 2016, 215 patients with suspected appendicitis were examined with DMS. The DMS findings were recorded as positive and negative for acute appendicitis and compared with the histopathological results, as a gold standard

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Comparison of Some Suggested Estimators Based on Differencing Technique in the Partial Linear Model Using Simulation
...Show More Authors

In this paper new methods were presented based on technique of differences which is the difference- based modified jackknifed generalized ridge regression estimator(DMJGR) and difference-based generalized  jackknifed ridge regression estimator(DGJR), in estimating the parameters of linear part of the partially linear model. As for the nonlinear part represented by the nonparametric function, it was estimated using Nadaraya Watson smoother. The partially linear model was compared using these proposed methods with other estimators based on differencing technique through the MSE comparison criterion in simulation study.

View Publication Preview PDF
Crossref (1)
Scopus Clarivate Crossref