Existence of these soils, sometimes with high gypsum content, caused difficult problems to the buildings and strategic projects due to dissolution and leaching of gypsum by the action of waterflow through soil mass. In this research, a new technique is adopted to investigate the performance of replacement and geosynthetic reinforcement materials to improve the gypseous soil behavior through experimential set up manufactured loaclally specially for this work. A series of tests were carried out using steel container (600*600*500) mm. A square footing (100*100) mm was placed at the center of the top surface of the bed soil. The results showed that the most effective thickness for the dune sand layer with geotextile at the interface, within the tested range, was found to be almost equal to the width of foundation. Therefore, under this depth, the soil was reinforced with geogrid
and geotextile. It can be shown that (Collapse Settlement Reduction Factor) increases to (72%) when using two layers of geogrid and one layer of geotextile under depth of replacement equal to the width of footing. In addition, the results showed that the bearing capacity increases to (1.5-2.0) time under concentric loads and (2.5-3) under eccentric loads after replacement and reinforcement of gypseous soil
Plastic soil exhibits unfavorited geotechnical properties (when saturation), which causes negative defects to engineering structures. Different attempts (included various materials) were conducted to proffer solutions to such defects by experimenting in practical ways. On one hand, these attempts aimed to improve the engineering characteristics of plastic soil, and on the other hand, to use problematic waste materials as a stabilizer, like cement kiln dust, and to reduce environmental hazards. This paper explored the shrinkage, plasticity, and strength behavior of plastic soil enhanced with cement dust. The cement dust contents were 0%, 5%, 10%, 15% and 20% by dry weight of soil. An experimental series of shrinkage and p
... Show MoreThe complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to di
... Show MoreFoundations supporting reciprocating engines, radar towers, turbines, large electric motors, and generators, etc. are subject to vibrations caused by unbalanced machine forces as well as the static weight of the machine. If these vibrations are excessive, they may damage the machine or cause it not to function properly. In the case of block foundation, if changes in size and mass of the foundation do not lead to a satisfactory design, a pile foundation may be used. In this study, the dynamic response of piles and pile Groups in dry sand is investigated experimentally. The analysis involves the displacement response under harmonic excitation. In addition, a numerical modeling by using finite element method with a three-dimensional formula
... Show MoreThe sun which is all energy sources, in today's society, hot water is used for various purposes starting from household to power production. People are adopting various ways to accomplish these goals, such as firewood heat and electrical power, so solar energy is an alternative to the dwindling resources of fossil fuels. Conversion of solar radiation into heat is one of the simplest and most direct applications of this energy, it can be used to heat water systems. A widely used flat-plate solar collector. In this study we have come to heat water using solar energy. This research presents the design and experimental analysis for using Spiral Flow Solar Water Heater (SFSWH) to enhance the thermal efficiency of a flat plate solar collector.
... Show MoreRenal failure is a disease of the kidney, in which the renal excretory function is failed to process due to depression of the GFR. Renal failure is divided into acute and chronic depending on the period of the disease. The study was designed to investigate the level of oxidative stress in RF patients. Seventy-five subjects had enrolled in the study, who divided into three groups equally, in which they are healthy control, ARF patients, and CRF patients. The results had shown a significant
Background: Chronic periodontitis (CP) is greatly prevalent condition of inflammatory behavior. Salivary biomarker total antioxidants capacity (T-AOC) status, may be related to both periodontal condition and oral hygiene. Aims of the study: To assess the level of salivary T-AOC of patients with chronic periodontitis in comparison to healthy control and to correlate between the level of this marker with the clinical periodontal parameters (plaque index (PLI), gingival index (GI), bleeding on probing (BOP), probing pocket depth (PPD), and clinical attachment level (CAL)). Materials and Methods: Ninety subjects of males and females with an age ranged between (35-55) years were participated in this study. Participants were divided into two grou
... Show MoreThis study was conducted to examine the discharge capacity of the reach of the Tigris River between Kut and Amarah Barrages of 250km in length. The examination includes simulation the current capacity of the reach by using HEC-RAS model. 247cross sections surveyed in 2012 were used in the simulation. The model was calibrated using observed discharges of 533, 800, 1025 and 3000m3/s discharged at Kut Barrage during 2013, 1995, 1995 and 1988, respectively, and its related water level at three gauge stations located along the reach. The result of calibration process indicated that the lowest Root Mean Square Error of 0.095 can be obtained when using Manning’s n coefficient of 0.026, 0.03 for th
... Show MoreIncreasing demands on producing environmentally friendly products are becoming a driving force for designing highly active catalysts. Thus, surfaces that efficiently catalyse the nitrogen reduction reactions are greatly sought in moderating air-pollutant emissions. This contribution aims to computationally investigate the hydrodenitrogenation (HDN) networks of pyridine over the γ-Mo2N(111) surface using a density functional theory (DFT) approach. Various adsorption configurations have been considered for the molecularly adsorbed pyridine. Findings indicate that pyridine can be adsorbed via side-on and end-on modes in six geometries in which one adsorption site is revealed to have the lowest adsorption energy (–45.3 kcal/mol). Over a nitr
... Show MoreThis paper focus on study the variations of monthly tropospheric NO2 concentrations over three Iraqi cities Baghdad (33.3° N, 44.4° E), Basrah (30.56° N, 47.8° E) and Erbil (36.3° N, 44.06° E). Monthly NO2 retrievals from the Ozone Monitoring Instrument (OMI) onboard Aura satellite during the period from October 2004 to March 2013 have been used. The results show a high monthly and annual NO2 concentrations at Baghdad than Basra and Erbil may be attribute to high densely populations and a high economic activity. During the whole period, Baghdad, Basrah and Erbil were exhibited an average of NO2 (8.1±2.5), (3.7±1.3) and (3.3±1.7) in unit 1015 molecules
... Show MoreIn this study; a three-dimensional model was created to simulate groundwater in Al-Haydariyah area of the governorate of Al-Najaf. A solid model was created to utilize the cross sections of 25 boreholes in the research region, and it was made out of two layers: sand and clay. The steady-state calibration was employed in six observation wells to calibrate the model and establish the hydraulic conductivity, which was 17.49 m/d for sand and 1.042 m/d for clay, with a recharge rate of 0.00007 m/day. The wells in the research region were reallocated with a distance of 1500 m between each well, resulting in 140 wells evenly distributed throughout the study area and with a discharge of 5 l/s, and the scenarios were run for 1000
... Show More