Equilibrium Moisture sorption isotherms are very important in drying and storage analysis. Experimental moisture equilibrium data (adsorption and desorption) of Aspirin were determined using the static method of saturated salt solutions and that by exposing the material to different conditions of temperatures and water activities. Three different temperatures (25, 30, 40Cº) and water activities in the range of (6.3- 83.6%) were used. The results showed that the equilibrium moisture content increased with the increase in water activity at any temperature and decreased with temperature increase at constant water activity. The water activity increases with increasing in temperature when moisture content was kept constant. The sorption isotherm curves are of type II according to Brunauer`s classification. The hysteresis effect was not distinctly expressed only for equilibrium sorption
values of Aspirin at 25ºC. The experimental results were fitted to two sorption models (GAB and Henderson).The average relative deviation between the experimental and calculated data were obtained to select the best model. The GAB and Henderson models, obtaining values of 3.54 and 1.42 % average relative deviation and coefficient of regression of 0.98 and 0.977 respectively. The Henderson model was found to be the best fit out of the two models to predict the sorption behavior of Aspirin.
Abstract The surface of kaolin was diagnosed by an AFM and the results were shown The height of the highest peak reached by a quantity of Kaolin surface is 2.5 µm, the granules, and their diameter with an average diameter of 666.1nm. Using Kaolin's adsorption properties, erythrosine was removed of its aqueous solution. It was determined that the maximal dye adsorption ranged 36.53–40.61%. The results of using the Freundlich, Langmuir, and Temkin adsorption isotherms revealed that at temperatures of (298,308,318) K, the Freundlich model was followed, the Langmuir model did not match, and the Temkin model could only be partially applied. There is also physical adsorption. One of the three kinetic models of the
... Show MoreManual probing and periodontal charting are the gold standard for periodontal diagnosis that have been used in practice over a century. These methods are affordable and reliable but they are associated with some drawbacks that cannot be avoided. Among these issues is their reliance on operator’s skills, time-consuming and tedious procedure, lack sensitivity especially in cases of early bone loss, and causing discomfort to the patient. Availability of a wide range of biomarkers in the oral biofluids, dental biofilm, and tissues that potentially reflect the periodontal health and disease accurately encouraged their use as predictive/diagnostic/monitoring tools. Analysing biomarkers during care-giving to the patient using chairside kits i
... Show MoreIt is an established fact that substantial amounts of oil usually remain in a reservoir after primary and secondary processes. Therefore; there is an ongoing effort to sweep that remaining oil. Field optimization includes many techniques. Horizontal wells are one of the most motivating factors for field optimization. The selection of new horizontal wells must be accompanied with the right selection of the well locations. However, modeling horizontal well locations by a trial and error method is a time consuming method. Therefore; a method of Artificial Neural Network (ANN) has been employed which helps to predict the optimum performance via proposed new wells locations by incorporatin
We report here the observation of 16 µm superradiance laser action generated from optical pumping of CF4 gas molecules (which is cooled to 140 Kº by a boil-off liquid-N2) by a TEA-CO2 laser 9R12 line. Output laser pulses of 7 mJ and 200 ns have been obtained.
Agricultural nozzles usually produce a different drops size depending on the pressure and the physical condition (work life) of the nozzle besides producing a wide range of the drops spectrum in the spray cloud. In this paper the standard flat fan nozzles were investigated regarding the effect of the working pressure and the nozzle physical condition (new and worn nozzles). The size of drops and the spectrum of drops across the long axis of the spray pattern were examined by using Sympatec GmbH Laser Diffraction. Reducing the working pressure from 3 to 2 and then to 1 caused production of larger drops, also using worn nozzles (especially with lower pressure) changed the drops size whi
In practical engineering problems, uncertainty exists not only in external excitations but also in structural parameters. This study investigates the influence of structural geometry, elastic modulus, mass density, and section dimension uncertainty on the stochastic earthquake response of portal frames subjected to random ground motions. The North-South component of the El Centro earthquake in 1940 in California is selected as the ground excitation. Using the power spectral density function, the two-dimensional finite element model of the portal frame’s base motion is modified to account for random ground motions. A probabilistic study of the portal frame structure using stochastic finite elements utilizing Monte Carlo simulation
... Show MoreEvaluate the acute and chronic toxicity of Ruta Chalepensis aerial part aqueous extract used in folk medicine in Iraq in Albino Wistar male and female rats. The study of chronic toxicity at the doses 100, 300 and 600mg/kg body weight in male and female rats for 90 days, recorded no mortality. Treated animals showed a normal weight change compared with control. The parameters of male fertility showed a significant decrease in the weight of testis, epididymis and seminal vesicle as well as a reduction in the number and the motility of spermatozoids at treated groups by the doses 300 and 600 mg/kg body weight compared to control group.
This work presents experimental research using draped prestressed steel strands to improve the load-carrying capacity of prestressed concrete non-prismatic beams with multiple openings of various designs. The short-term deflection of non-prismatic prestressed concrete beams (NPCBs) flexural members under static loading were used to evaluate this improvement. Six simply supported (NPCBs) beams, five beams with openings, and one solid specimen used as a reference beam were all tested as part of the experiment. All of the beams were subjected to a monotonic midpoint load test. The configuration of the opening (quadrilateral or circular), as well as the depth of the chords, were the varia