The effect of linear thermal stratification in stable stationary ambient fluid on free convective flow of a viscous incompressible fluid along a plane wall is numerically investigated in the present work. The governing equations of continuity, momentum and energy are solved numerically using finite difference method with Alternating Direct implicit Scheme. The velocity, temperature distributions
and the Nusselt number are discussed numerically for various values of physical parameters and presented through graphs. ANSYS program also used to solve the problem. The results show that the effect of stratification parameter is marginalized with the increase in Prandtl number, and the increase in Grashof number does not practically vary the effect of stratification parameter.
The two-dimensional transient heat conduction through a thermal insulation of temperature dependent thermal properties is investigated numerically using the FVM. It is assumed that this insulating material is initially at a uniform temperature. Then, it is suddenly subjected at its inner surface with a step change in temperature and subjected at its outer surface with a natural convection boundary condition associated with a periodic change in ambient temperature and heat flux of solar radiation. Two thermal insulation materials were selected. The fully implicit time scheme is selected to represent the time discretization. The arithmetic mean thermal conductivity is chosen to be the value of the approximated thermal conductivity at the i
... Show MoreApplying a well-performing heat exchanger is an efficient way to fortify the relatively low thermal response of phase-change materials (PCMs), which have broad application prospects in the fields of thermal management and energy storage. In this study, an improved PCM melting and solidification in corrugated (zigzag) plate heat exchanger are numerically examined compared with smooth (flat) plate heat exchanger in both horizontal and vertical positions. The effects of the channel width (0.5 W, W, and 2 W) and the airflow temperature (318 K, 323 K, and 328 K) are exclusively studied and reported. The results reveal the much better performance of the horizontal corrugated configuration compared with the smooth channel during both melti
... Show MoreInvestment Bases directly and closely to an environment characterized by political, social and economic stability, and through a range of policies and institutions and economic laws that affect investor confidence and convince him directing investments to country without the other, where inter conditions and circumstances affecting the trends of capital and settle in, and political situation of the country and what is characterized of stability or disorder as well as economic conditions that are affected by what is distinguishes the country from geographic and demographic characteristics are reflected on availability of production elements and country's infrastructure.
... Show MoreThe problem of independent motion control of mobile robot (МR) in conditions when unforeseen changes of conditions of interaction of wheels with a surface are considered. An example of such changes can be sudden entrance МR a slippery surface. The deployment of an autonomous unmanned ground vehicle for field applications provides the means by which the risk to personnel can be minimized and operational capabilities improved. In rough terrain, it is critical for mobile robots to maintain good wheel traction. Wheel slip could cause the rover to lose control and become trapped. This paper describes the application of fuzzy control to a feedback system within slippery environment. The study is conducted on an example of М
... Show Moreحضيت القيادة باهتمام كبير من قبل الباحثين ودورها الإيجابي في التأثير على الموظفين ونجاح المنظمات، في الآونة الأخير بدأت الدراسات تركز على الجانب المظلم للقيادة وتأثيرها على التابعين وبيئة العمل، وقد تم تحديد القيادة السامة بأنها أخطر الأساليب القيادية التي تتسبب بتكاليف مادية ومعنوية على المنظمات بمختلف جوانبها، ان القيادة السامة تأثر على دوافع المرؤوسين وقدرتهم على انجاز المهام، ورغبتهم في الاستمرار في
... Show MoreStandards of audit have been defined issued them by professional organizations the audit risk is: Failure of the auditor inadvertently to amend his opinion on the financial statements in suitable method, although these statements are Interpolated Essentially. As result the deep impacts caused by electronic operating systems in the accounting data in the audit process which audit risk has gained attention of many professional sides, especially the audit process and quality is relating with level of discovery the auditor for the mistakes of origin (misrepresentations) all their types and give the necessary confidence for the auditor to express his technical opinion in fidelity and certified financial statements which prepared electronicall
... Show MoreObjectives: To evaluate the families’ attitudes toward environment pollution, and determine the relationship
between families’ attitudes towards environment pollution and their demographic characteristics of age,
education, type of family, and socioeconomic status.
Methodology: A descriptive design is carried throughout the present study to evaluate families’ attitudes toward
environment pollution for the period of October 5th2013 to May 7th2014. A non-probability "purposive" sample of
(110) families’ is selected. The sample is comprised of two groups; (75) urban families’ and (35) rural ones. An
evaluation tool is designed and constructed for the purpose of the study. It is consisted of (4) main parts;
dem
In this study, the effect of design parameters such as pipe diameter, pipe wall thickness, pipe material and the effect of fluid velocity on the natural frequency of fluid-structure interaction in straight pipe conveying fully developed turbulent flow were investigate numerically,analytically and experimentally. Also the effect of support conditions, simply-simply and clamped-clamped was investigated. Experimentally, pipe vibrations were characterized by accelerometer mounted on the pipe wall. The natural frequencies of vibration were analyzed by using Fast Fourier Transformer (FFT). Five test sections of two different pipe diameters of 76.2
mm and 50.8 mm with two pipe thicknesses of 3.7 mm and 2.4 mm and two pipe materials,stainles