Preferred Language
Articles
/
joe-205
Investigation the Optimum Combined Dosages of Date Seeds Powder as Natural Coagulant with Chemical Coagulants in Domestic Wastewater Pretreatment
...Show More Authors

The pretreatment process can be considered one of the important processes in wastewater treatment, especially coagulation process to decrease the strength of many pollutants. This paper focused on using powdered date seeds as natural coagulant in addition to chemical coagulants (alum and ferric chloride) to find the optimum dosage of each coagulant that makes efficient removal of turbidity and chemical oxygen demand (COD) from domestic wastewater as a pretreatment process, then finding the optimum combined dosages of date seeds with alum, date seeds with ferric chloride that make efficient removal for both pollutants. Concerning turbidity, the optimum dosage for date seeds, alum and ferric chloride were 40 mg/l (79%), 70 mg/l (84%) and 60 mg/l (82%) respectively.  Concerning COD the optimum dosage for date seeds, alum, and ferric chloride were 40 mg/l (75%), 60 mg/l (83%) and 50 mg/l (86%). The study showed that the optimum combined dosage that made higher turbidity removal (95%) resulted from mixing 70 mg/l date seeds with 50 mg/l alum, while for higher COD removal 90% resulted from mixing 40 mg/l date sees with 70 mg/l ferric chloride.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 20 2020
Journal Name
Al-mustansiriyah Journal Of Science
Seasonal Variations of the Optimum Reliable Frequencies During Maximum and Minimum Periods of Solar Cycle 24
...Show More Authors

In this research, the seasonal Optimal Reliable Frequency (ORF) variations between different transmitter/receiver stations have been determined. Mosul, Baghdad, and Basra have been chosen as tested transmitting stations that located in the northern, center, and southern of Iraqi zone. In this research, the minimum and maximum years (2009 and 2014) of solar cycle 24 have been chosen to examine the effect of solar activity on the determined seasonal ORF parameter. Mathematical model has been proposed which leads to generate the Optimal Reliable Frequency that can maintain the seasonal connection links for different path lengths and bearings. The suggested ORF parameter represented by a different orders polynomial equation. The polynom

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of The Mechanical Behavior Of Materials
Investigation of the performance of integrated intelligent models to predict the roughness of Ti6Al4V end-milled surface with uncoated cutting tool
...Show More Authors
Abstract<p>Titanium alloys are broadly used in the medical and aerospace sectors. However, they are categorized within the hard-to-machine alloys ascribed to their higher chemical reactivity and lower thermal conductivity. This aim of this research was to study the impact of the dry-end-milling process with an uncoated tool on the produced surface roughness of Ti6Al4V alloy. This research aims to study the impact of the dry-end milling process with an uncoated tool on the produced surface roughness of Ti6Al4V alloy. Also, it seeks to develop a new hybrid neural model based on the training back propagation neural network (BPNN) with swarm optimization-gravitation search hybrid algorithms (PSO-GS</p> ... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
OPTIMUM WATER ALLOCATION FOR ABO-ZIRIQ MARSH ECOLOGICAL RESTORATION
...Show More Authors

Optimum allocation of water for restoration of Iraqi marshes is essential for different related authorities. Abo-Ziriq marsh area about 120 km2 is situated 40 km east of Al-Nassryia city. After comparing the measured annual water qualities with the Iraqi standards for surface water quality evaluation, Abo-Ziriq marsh water quality was in acceptable limit. Hydro balance computation were done for each month by using interface among the HEC-RAS, HEC-GeoRAS and ArcView GIS software and built a number of eco-hydro relationships to simulate the marsh ecosystem by using HEC-EFM program to estimate water allocation adequate for ecosystem requirement and constructs a GIS hydraulic reference map to show inundation area, depth grid and velocity dis

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
Determination Optimum Inventory Level for Material Using Genetic Algorithm
...Show More Authors

The integration of decision-making will lead to the robust of its decisions, and then determination optimum inventory level to the required materials to produce and reduce the total cost by the cooperation of purchasing department with inventory department and also with other company,s departments. Two models are suggested to determine Optimum Inventory Level (OIL), the first model (OIL-model 1) assumed that the inventory level for materials quantities equal to the required materials, while the second model (OIL-model 2) assumed that the inventory level for materials quantities more than the required materials for the next period.             &nb

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Aip Conference Proceedings
Synthesis and characterization of nano silica from Iraqi sand by chemical precipitation with different acid types
...Show More Authors

View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Thu Feb 26 2026
Journal Name
Int. J. Corros. Scale Inhib.
DFT and experimental investigation of a novel 1,2,4-triazole derivative as a corrosion inhibitor for carbon steel A106 G/B in HCl solution
...Show More Authors

This work introduces a newly synthesized triazole derivative, 5-([(2-furanyl)methyl]-thiomethyl)-4-(naphtha-2-yl)-3-hydroxyl-4H-1,2,4-triazole (FTNT), as an effective corrosion inhibitor for carbon steel A106 G/B in 0.1 M HCl solution. The structure of the novel derivative was confirmed by FTIR, 1 H NMR, and 13 C NMR spectra. Potentiodynamic polarization measurements reveal that FTNT markedly suppresses corrosion, with inhibition efficiency reaching 81.6% at 600 ppm. Thermodynamic analysis indicates spontaneous, physisorption/chemisorption-augmented adsorption of FTNT on the steel surface, best described by the Freundlich isotherm. Atomic force microscopy (AFM) surface examination demonstrated that a protective FTNT coating precipitated on

... Show More
Publication Date
Fri Apr 01 2022
Journal Name
Chalcogenide Letters
The dependence of the energy density states on the substitution of chemical elements in the Se6Te4-xSbx thin film
...Show More Authors

The energy density state are the powerful factor for evaluate the validity of a material in any application. This research focused on examining the electrical properties of the Se6Te4- xSbx glass semiconductor with x=1, 2 and 3, using the thermal evaporation technique. D.C electrical conductivity was used by determine the current, voltage and temperatures, where the electrical conductivity was studied as a function of temperature and the mechanical electrical conduction were determined in the different conduction regions (the extended and localized area and at the Fermi level). In addition, the density of the energy states in these regions is calculated using the mathematical equations. The constants of energy density states are det

... Show More
View Publication
Scopus (36)
Crossref (31)
Scopus Crossref
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More