Preferred Language
Articles
/
joe-2059
Investigation of Backfill Compaction Effect on Buried Concrete Pipes
...Show More Authors

The present study deals with the experimental investigation of buried concrete pipes. Concrete pipes are buried in loose and dense conditions of gravelly sand soil and subjected to different surface loadings to study the effects of the backfill compaction on the pipe. The experimental investigation was accomplished using full-scale precast unreinforced concrete pipes with 300 mm internal diameter tested in a laboratory soil box test facility set up for this study. Two loading platforms are used namely, uniform loading platform and patch loading platform. The wheel load was simulated through patch loading platform which have dimensions of 254 mm *508 mm, which is used by AASHTO to model the wheel load of a HS20 truck. The pipe-soil systems were loaded up to pipes collapse. Pipes were instrumented with strain gauges to measure circumferential strains, in addition to dial gauges, for measurements of the pipe vertical deflections and settlement of the loading platforms. The test results indicated that flexure governed the buried pipe behavior. Flexural cracks formed slightly before the ultimate load. A comparison of soil backfill, between a loose and dense compaction, showed that the dense backfill improve largely the pipe installation and the strength of
pipe-soil system

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 13 2023
Journal Name
Engineering, Technology & Applied Science Research
The Experimental and Theoretical Effect of Fire on the Structural Behavior of Laced Reinforced Concrete Deep Beams
...Show More Authors

A Laced Reinforced Concrete (LRC) structural element comprises continuously inclined shear reinforcement in the form of lacing that connects the longitudinal reinforcements on both faces of the structural element. This study conducted a theoretical investigation of LRC deep beams to predict their behavior after exposure to fire and high temperatures. Four simply supported reinforced concrete beams of 1500 mm, 200 mm, and 240 mm length, width, and depth, respectively, were considered. The specimens were identical in terms of compressive strength (  40 MPa) and steel reinforcement details. The same laced steel reinforcement ratio of 0.0035 was used. Three specimens were burned at variable durations and steady-state temperatures (one

... Show More
View Publication
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu May 17 2018
Journal Name
Archaeological Prospection
Very‐high‐resolution electrical resistivity imaging of buried foundations of a Roman villa near Nonnweiler, Germany
...Show More Authors
Abstract<p>Electrical resistivity tomography (ERT) methods have been increasingly used in various shallow depth archaeological prospections in the last few decades. These non‐invasive techniques can save time, costs, and efforts in archaeological prospection and yield detailed images of subsurface anomalies. We present the results of quasi‐three‐dimensional (3D) ERT measurements in an area of a presumed Roman construction, using a dense electrode network of parallel and orthogonal profiles in dipole–dipole configuration. A roll‐along technique has been utilized to cover a large part of the archaeological site with a 25 cm electrode and profile spacing, respectively. We have designed a new field proce</p> ... Show More
View Publication
Scopus (20)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Construction And Building Materials
Uni- and tri-axial tests and property characterization for thermomechanical effect on hydrated lime modified asphalt concrete
...Show More Authors

Permanent deformation, fatigue and thermal cracking are the three typical distresses of flexible pavement. Using hydrated lime (HL) into the conventional limestone mineral additive has been widely practiced, including in Europe, to improve the mechanical properties of hot mix asphalt (HMA) concrete and as the result the durability of the constructed pavement. Large number of experimental studies have been reported to find the optimum addition of HL for the improvement on HMA concrete mechanical properties, moisture susceptibility and fatigue resistance. Pavement in service is under complex thermomechanical stress-strain conditions due to coupled atmospheric and surrounding environment temperature variation and the traffic loading. To predic

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Experimental and Theoretical Investigation of Noise Effect in Centrifugal Fan Impeller
...Show More Authors

In this work a study was made in centrifugal fan blower to investigate the effect of impeller blade design on sound pressure level (SPL). Shroud and unshroud impeller of nine blades are used. The sound generation from flow inside the test rig at different positions was displayed by using spectral analyzer. The experiments were carried out in anechoic chamber with small holes in its walls, under ambient condition about (25-27) C ° to avoid the effect of temperature on the sound pressure level. The results showed that (SPL) decreased with the increase of distance from the source about (3-4)dB when distance varied about (0.8-1.06)m, and the (SPL) decreased with the decrease of velocity about (8-12)dB when velocity varied between (13000-260

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
The Effect of Using Different Aspect Ratios of Sustainable Copper Fiber on Some Mechanical Properties of High-Strength Green Concrete
...Show More Authors

To achieve sustainability, use waste materials to make concrete to use alternative components and reduce the production of Portland cement. Lime cement was used instead of Portland cement, and 15% of the cement's weight was replaced with silica fume. Also used were eco-friendly fibers (copper fiber) made from recycled electrical. This work examines the impact of utilizing sustainable copper fiber with different aspect ratios (l/d) on some mechanical properties of high-strength green concrete. A high-strength cement mixture with a compressive strength of 65 MPa in line with ACI 211.4R was required to complete the assignment. Copper fibers of 1% by volume of concrete were employed in mixes with four different aspect ratios

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Journal Of Engineering
Crack Growth Behavior through Wall Pipes under Impact Loading And Moisten Environment
...Show More Authors

This search concerns study the crack growth in the wall of pipes made of low carbon steel under the impact load and using the effect of moisture (rate of moisture 50%). The environmental conditions were controlled using high accuracy digital control with sensors. The pipe has a crack already. The test was performed and on two type of specimens, one has a length of 100cm and other have length 50cm. The results were, when the humidity was applied to the pipe, the crack would enhance to grow (i.e. the number of cycles needed to grow the crack will reduce). In addition, when the test performed on the specimens of length 50cm the number of cycles needed to grow the crack is increased due to the effect of bending stress on the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Optimizing Viscous Flow in Pipes Through Improved Flow Conditions and Chemical Injections
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Cathodic Protection of Copper Pipes Carrying Saline Water in the Presence of Aerobic Bacteria
...Show More Authors

Rates of zinc consumption during cathodic protection of a copper pipeline carrying saline water were measured by the loss in weight technique. The study of sacrificial anode cathodic protection of short copper tube using zinc strip extended axially in the pipe revealed that : (i) The increase of zinc consumption with time of exposure (1-3 h's) at different flow rates (turbulent flow) (300-600 l/hr) while the temperature , solution concentration and the pH were fixed at 20ºC, 3.5%wt NaCl, and pH=8 respectively in absence and presence of bacteria.(ii)Increase of zinc consumption with flow rates (300-600 l/hr) at different temperatures (10-40ºC) while solution concentration and time of exposure were fixed at 3.5 %wt NaCl and 3hr's respect

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Cathodic Protection of Copper Pipes Carrying Saline Water in the Presence of Aerobic Bacteria
...Show More Authors

Rates of zinc consumption during cathodic protection of a copper pipeline carrying saline water were measured by the loss in weight technique. The study of sacrificial anode cathodic protection of short copper tube using zinc strip extended axially in the pipe revealed that : (i) The increase of zinc consumption with time of exposure (1-3 h's) at different flow rates (turbulent flow) (300-600 l/hr) while the temperature , solution concentration and the pH were fixed at 20ºC, 3.5%wt NaCl, and pH=8 respectively in absence and presence of bacteria.(ii)Increase of zinc consumption with flow rates (300-600 l/hr) at different temperatures (10-40ºC) while solution concentration and time of exposure were fixed at 3.5 %wt NaCl and 3hr's respective

... Show More
Preview PDF
Publication Date
Sun Jan 27 2019
Journal Name
Civil Engineering Journal
Effect of Size and Location of Square Web Openings on the Entire Behavior of Reinforced Concrete Deep Beams
...Show More Authors

This paper presents an experimental and numerical study which was carried out to examine the influence of the size and the layout of the web openings on the load carrying capacity and the serviceability of reinforced concrete deep beams. Five full-scale simply supported reinforced concrete deep beams with two large web openings created in shear regions were tested up to failure. The shear span to overall depth ratio was (1.1). Square openings were located symmetrically relative to the midspan section either at the midpoint or at the interior boundaries of the shear span. Two different side dimensions for the square openings were considered, mainly, (200) mm and (230) mm. The strength results proved that the shear capacity of the dee

... Show More
View Publication
Crossref (12)
Crossref