A Strength Pareto Evolutionary Algorithm 2 (SPEA 2) approach for solving the multi-objective Environmental / Economic Power Dispatch (EEPD) problem is presented in this paper. In the past fuel cost consumption minimization was the aim (a single objective function) of economic power dispatch problem. Since the clean air act amendments have been applied to reduce SO2 and NOX emissions from power plants, the utilities change their strategies in order to reduce pollution and atmospheric emission as well, adding emission minimization as other objective function made economic power dispatch (EPD) a multi-objective problem having conflicting objectives. SPEA2 is the improved version of SPEA with better fitness assignment, density estimation, and modified archive truncation. In addition fuzzy set theory is employed to extract the best compromise solution. Several optimization run of the proposed method are carried out on 3-units system and 6-units standard IEEE 30-bus test system. The results demonstrate the capabilities of the proposed method to generate well-distributed Pareto-optimal non-dominated feasible solutions in single run. The comparison with other multi-objective methods demonstrates the superiority of the proposed method.
تضاعف انتشار مرض السكري من النوع 2 في السنوات الأخيرة نتيجة الخلل في إنتاج الأنسولين ، والذي يمكن أن يتطور ليشكل مضاعفات مرض السكري التي تؤثر على الكلى والأعصاب والعينين. ونتيجة لذلك ، فإن التشخيص المبكر والتصنيف لمرض السكري من النوع الثاني ضروريان لمساعدة الطبيب على التقييم. وفقًا لذلك ، هدفت الدراسة الحالية إلى تحديد مستويات بروتين ارتباط الريتينول 4 (RBP4) في المرضى الذين يعانون من السكري النوع الثاني وم
... Show MoreRetainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.
To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).
A two-arm parallel groups single-centre randomized c
To evaluate the effects of the ShotBlocker and vibration device on pain intensity and patient satisfaction during subcutaneous (SC) insulin injections in hospitalized adults with type 2 diabetes mellitus.
In this randomized controlled trial, 102 patients with type II diabetes mellitus were randomly assigned into 3 groups: 35 patients in the ShotBlocker group, 36 patients in the vibration group, and 31 patients in the control group. ShotBlocker was applied immediately before and during the injection, while the vibration was applied fo
In this work, the performance of the receiver in a quantum cryptography system based on BB84 protocol is scaled by calculating the Quantum Bit Error Rate (QBER) of the receiver. To apply this performance test, an optical setup was arranged and a circuit was designed and implemented to calculate the QBER. This electronic circuit is used to calculate the number of counts per second generated by the avalanche photodiodes set in the receiver. The calculated counts per second are used to calculate the QBER for the receiver that gives an indication for the performance of the receiver. Minimum QBER, 6%, was obtained with avalanche photodiode excess voltage equals to 2V and laser diode power of 3.16 nW at avalanche photodiode temperature of -10
... Show MoreDengue fever is a mosquito-borne viral infection that produces characteristic abnormalities in routine blood tests, yet these hematologic changes are typically analysed separately for each parameter rather than as a combined multivariate profile. This study investigated whether the joint hematologic profile of adult dengue patients in Bangladesh is systematically displaced from healthy adult reference values. We analysed a cohort of laboratory-confirmed adult dengue cases from a Bangladeshi hospital and focused on four core hematologic indices: haemoglobin, white blood cell count, platelet count, and platelet distribution width (PDW). External adult reference means were used to define a healthy location vector, and robust multivariate infer
... Show MoreMicrofluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)
... Show More