Preferred Language
Articles
/
joe-2035
Competitive Stripping of Multi-Organic Pollutants from Contaminated Water in Bubble Column Semi-Batch
...Show More Authors

Air  stripping  for  removal  of  Trichloroethylene  (TCE),  Chloroform  (CF)  and  Dichloromethane (DCM) from water were studied in a bubble column (0.073 m inside dia. and 1.08 m height with several sampling ports). The contaminated water was prepared from deionized water and VOCs. The presence of VOCs in feed solution was single, binary or ternary components. They were diluted to the concentrations ranged between 50 mg/l to 250 mg/l. The experiments were carried out in batch experiments which regard the bubble column as stirred tank and only gas was bubbled through stationary liquid. In this case transient measurements of VOC concentration in the liquid phase and the measured concentration profiles were modeled by bubble aeration model (BAM) to fit the experimental data fairly well. The results from batch experiments show that the removal efficiency of VOCs increases with increasing gas flow rate or gas holdup. It is found a pH=10 give the best removal rate, but all experiments were adjusted at pH=8 which allow to study other operating conditions. TCE is being removed faster than the other two components for all systems and a single component was removed faster than binary or ternary system. The KLa values were evaluated by fitting the BAM to the experimental data. It is found that KLa increased with increasing gas flow rate and TCE exhibits the highest KLa values.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 26 2024
Journal Name
Iraqi Journal Of Science
Comparison between Cefoxitin disk diffusion, Crome agar and EPI-M Screening Kit for Detection of Methicillin- Resistant Staphylococcus aureus
...Show More Authors

Specimens have been collected from one hundred and seventeen patients residing in local hospitals, 33 with burns and 84 wound injuries,. Three different methods ,Cefoxitin disk diffusion, EPI-M Screening Kit and Crome agar (MeReSa agar)with selective supplement were used to detect methicillin-resistant Staphylococcus aureus (MRSA) . A comparison was made between these 3 methods according to the results. It was found that the results of the Cefoxitin disk diffusion test were compatible with the results of culturing on Crome agar, while those obtained from the EPI-M Screening kit were not accurate and some of them gave false negative results.

View Publication Preview PDF
Publication Date
Mon Nov 05 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of Instruction-oriented Intervention for Primipara Women upon Episiotomy and Self-perineal Care at Ibn Al-Baladi Hospital
...Show More Authors

Objective: To identify the effectiveness of instruction oriented intervention for primipara women upon episiotomy and self
perineal care.
Methodology: A quasi-experimental study was carried out to determine the effectiveness of instruction-oriented
intervention for primipara women upon episiotomy and self-perineal care. A purposive "non-probability" sample of (60)
primipara mothers was selected from Ibn AL-Balady Pediatric and Maternity Hospital, Al-russafa, Baghdad. The sample
has been divided into two groups; (30) primipara women who were considered as a study group, and another (30) primipara
women who were considered as a control one. The study group was exposed to an instruction-oriented intervention. While,
the

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 06 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of incorporating carbon nanotubes on impact, transverse strength, hardness, and roughness to high impact denture base material
...Show More Authors

Background: One of the most common complications of dentures is its ability to fracture, so the aim of this study was to reinforce the high impact denture base with carbon nanotubes in different concentrations to improve the mechanical and physical properties of the denture base. Materials and methods: Three concentrations of carbon nanotubes was used 0.5%, 1%, 1.5% in a pilot study to see the best values regarding transverse strength, impact, hardness and roughness test, 1 wt% was the best concentration, so new samples for control group and 1wt% carbon nanotubes and the previous tests were of course repeated. Results: There was a significant increase in impact strength and transverse strength when we add carbon nanotubes in 1wt%, compared

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Serum Vascular Endothelial Growth Factor VEGF and Interlukin-8 As a Novel Biomarkers For Early Detection of Ovarian Tumors
...Show More Authors

Epithelial ovarian cancer is the leading cause of cancer deaths from gynecological malignancies. Angiogenesis is considered essential for tumor growth and the development of metastases. VEGF and IL?8 are potent angiostimulatory molecules and their expression has been demonstrated in many solid tumors, including ovarian cancer.VEGF and IL-8 concentrations were measured by ELISA test (HumanVEGF,IL-8). Bioassay ELISA/ US Biological / USA).The median VEGF and IL-8 levels were significantly higher in the sera of ovarian cancer patients than in those with benign tumors and in healthy controls.Pretreatment VEGF and IL-8 serum levels might be regarded as an additional tool in the differentiation of ovarian tumors.

View Publication Preview PDF
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Investigation of Beta and Gamma Rays Total Interaction Cross Section and Effective Atomic Number for CR-39Nuclear Track Detector
...Show More Authors

CR-39 is a solid state nuclear track detector (SSNTD) that has been used in many research areas. In spite of the assumption that the CR-39 detectors are insensitive to beta and gamma rays, irradiation with these rays can have significant effects on the detector properties. In this study, beta and gamma rays mass attenuation coefficients μ/ρ (cm2 g-1) for the CR-39 detector have been measured using NaI(Tl) scintillation spectrometer along with a standard geometrical arrangement in the energy region of (0.546-2.274) MeV beta rays and standard gamma sources having energy 0.356, 0.5697, 0.6617 and 1.063 MeV. The total atomic cross-section (σtot), total electronic cross-section (σT E) and the effective atomic number (Zeff) of gamma rays a

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Some Methods for Estimating the Survival Function and Failure Rate for the Exponentiated Expanded Power Function Distribution
...Show More Authors

 

     We have presented the distribution of the exponentiated expanded power function (EEPF) with four parameters, where this distribution was created by the exponentiated expanded method created by the scientist Gupta to expand the exponential distribution by adding a new shape parameter to the cumulative function of the distribution, resulting in a new distribution, and this method is characterized by obtaining a distribution that belongs for the exponential family. We also obtained a function of survival rate and failure rate for this distribution, where some mathematical properties were derived, then we used the method of maximum likelihood (ML) and method least squares developed  (LSD)

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Improve Performance of Solar Cell by using Grooves which Have Semicircular Shape on The Surface by using Program (ZEMAX)
...Show More Authors

 In this work silicon solar cell has been used with semicircular grooves to improve its efficiency by reducing reflection of rays and increasing optical path through the cell. Software program for optical design (zemax) has been used by ray tracing mode to evaluate prototype efficiency when using detector beneath the cell. The prototype has aspect ratio (A.R=0.2) which is the best efficiency at incident angle (Ï´=0ͦ) and the best acceptance angle (Ï´=50ͦ). 

View Publication Preview PDF
Publication Date
Fri Mar 10 2017
Journal Name
Superconductor Science And Technology
Conceptual designs of conduction cooled MgB<sub>2</sub> magnets for 1.5 and 3.0 T full body MRI systems
...Show More Authors

View Publication
Scopus (54)
Crossref (51)
Scopus Clarivate Crossref
Publication Date
Mon Oct 16 2023
Journal Name
F1000research
Assessment of general population knowledge, attitude, and practice on safe unused and expired drugs disposal: a cross-sectional study
...Show More Authors

Background The appropriate disposal of medication is a well-recognized issue that has convened growing recognition in several contexts. Insufficient awareness relating to appropriate methods for the disposal of unneeded medicine may result in notable consequences. The current research was conducted among the public in Iraq with the aim of examining their knowledge, attitude, and practices regarding the proper disposal of unused and expired medicines. Methods The present study used an observational cross-sectional design that was community-based. The data were obtained from using an online questionnaire. The study sample included people of diverse genders, regardless of their race or occupational status. The study mandated that all pa

... Show More
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Wed Mar 13 2024
Journal Name
Journal Of Robotics
Hierarchical Stabilization and Tracking Control of a Flexible-Joint Bipedal Robot Based on Anti-Windup and Adaptive Approximation Control
...Show More Authors

Bipedal robotic mechanisms are unstable due to the unilateral contact passive joint between the sole and the ground. Hierarchical control layers are crucial for creating walking patterns, stabilizing locomotion, and ensuring correct angular trajectories for bipedal joints due to the system’s various degrees of freedom. This work provides a hierarchical control scheme for a bipedal robot that focuses on balance (stabilization) and low-level tracking control while considering flexible joints. The stabilization control method uses the Newton–Euler formulation to establish a mathematical relationship between the zero-moment point (ZMP) and the center of mass (COM), resulting in highly nonlinear and coupled dynamic equations. Adaptiv

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref