Air stripping for removal of Trichloroethylene (TCE), Chloroform (CF) and Dichloromethane (DCM) from water were studied in a bubble column (0.073 m inside dia. and 1.08 m height with several sampling ports). The contaminated water was prepared from deionized water and VOCs. The presence of VOCs in feed solution was single, binary or ternary components. They were diluted to the concentrations ranged between 50 mg/l to 250 mg/l. The experiments were carried out in batch experiments which regard the bubble column as stirred tank and only gas was bubbled through stationary liquid. In this case transient measurements of VOC concentration in the liquid phase and the measured concentration profiles were modeled by bubble aeration model (BAM) to fit the experimental data fairly well. The results from batch experiments show that the removal efficiency of VOCs increases with increasing gas flow rate or gas holdup. It is found a pH=10 give the best removal rate, but all experiments were adjusted at pH=8 which allow to study other operating conditions. TCE is being removed faster than the other two components for all systems and a single component was removed faster than binary or ternary system. The KLa values were evaluated by fitting the BAM to the experimental data. It is found that KLa increased with increasing gas flow rate and TCE exhibits the highest KLa values.
Groundwater is very important for different uses in the present study area which represents Jisr Diyala, located in southeastern Baghdad and covered with quaternary deposits which include the shallow aquifer in the area. Groundwater and surface water were investigated to determine their suitable uses. The main ion concentrations of the wet period seemed to be lower than those in the dry period. According to TDS values, the water is classified as brackish to salty with a high degree of hardness. Most of water samples were of NaCl type due to pollution with sewage water and rock-water interaction. The results show that the water of the study area is suitable for livestock and irrigation purposes only.
A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r
... Show MoreOne of the goals of adding adjuvants to agricultural spray solutions is to enhance the droplet size characteristics of this spray. Droplet size, in turn, has an influence in the deposited spray quality, in addition to the drift and losses of spray to off-target places. The aim of this research was to evaluate the effect of adding adjuvants to two types of water from different sources on the droplet size characteristics. Two types of adjuvants were employed in the tests: the active substance content of the first adjuvant was a 50% aqueous solution of sodium salt of alkylbenzenesulfonic acid—10% (HY), whereas the second was from rapeseed oil (natural origin)—85% (OL). Both adjuvants were tested in two concentrations: the first was
... Show MoreThe chlorine concentration variation in Baghdad water networks was studied. The
chlorine data were collected from Mayoralty of Baghdad and Ministry of Environment
(MOE) for the networks for both sides of the city Karkh and Rasafa for (2008-2009). The
study of these data indicates that there are no systematic testing program .Classified GIS
maps showed that the areas far from the treatment plants have almost always low
chlorine concentration .This indicates that the problem of the low chlorine concentration
in the far areas is due to cracks of pipe along the conveyance path ,as expected. The area's
most frequently have low concentration are Al-sadir,Al-Kadhimya, and Al-Amiria . It
was found also that the chlorine c
Groundwater quality deterioration due to anthropogenic natural activities and its immense utilization in various sectors is considered a great concern. The aim of this study is to determine the groundwater quality parameters at various sources in and around Dhaka city and compare them with Bangladesh drinking water standards. In this study, six groundwater quality parameters (pH, DO, COD, TS, TDS, and arsenic) and ten groundwater samples are analyzed to determine the water quality. The collected samples have maximum and minimum pH values of 6.9 and 6.4, respectively. Maximum and minimum DO values are 0.3 and 0.1 mg/L, respectively. The arsenic concentration is 0 mg/L for all collected groundwater samples. The maximum and minimum COD
... Show MoreThin films of Magnetite have been deposited on Galvanized Steel (G-S) alloy using RF-reactive magnetron sputtering technique and protection efficiency of the corrosion of G-S. A Three-Electrodes Cell was used in saline water (3.5 % NaCl) solution at different temperatures (298, 308, 318 & 328K) using potentiostatic techniques with. Electrochemical Impedance Spectroscopy (EIS) and fitting impedance data via Frequency Response Analysis (FRA) were applied to G-S alloy with Fe3O4 and tested in 3.5 % NaCl solution at 298K.Results taken from Nyquist and Bode plots were analyzed using software provided with the instrument. The results obtained show that the rate of corrosion of G.S alloy increased with increasing the temperatures from 298 t
... Show MoreThe determination of river pollution impact on the performance of water treatment plants is achieved by two main objectives. The first is to study raw and treated water qualities and comparing them with standards and the second is to evaluate the treatment plants efficiency. The analyzed data were those water quality parameters in relation to physical, chemical and bacteriological characteristics for river water and produced water by seven water treatment plants located on Tigris River passing through Baghdad City.
The results of this study indicated that all raw water characteristic are within the surface water standards established by Iraqi and USA criteria except Bacterial Counts.
Tigris River water is of good quality to be trea
The meteorological data recorded in Al-Hilla station for the period (1984-2014) were used to describe the climatic condition of the Greater Musaiyab Project lies in Babylon Governorate, 90Km southern of Baghdad City, central of Iraq. This study found that the summation of rainfall is (112.323 mm), average of relative humidity (47.44%), temperature (25.55 C◦), sunshine (8.748 h/day) and the total of evaporation is (2268.463 mm). In this research, three classifications were applied to find the type of climate in the study area. The results of the climate classification show that, the climate of study area is characterized by dry and relatively hot in summer, and cold with low rain in winter. Thornthwiat equation was used to determine the
... Show MoreRadon concentrations are measured for water samples collected from twenty wells which were drilled in Hashimiya area in addition to twelve samples of surface water using Alpha Gaurd. 140 samples, 7 for each well, were collected represent wet season in continuous pumping and 20 samples, one for each well, were collected represent dry season. Concentration of radon in groundwater is many times of its concentration in surface water. The minimum concentration in groundwater is about (7) Bq/L and (5) Bq/L while the maximum concentration is about (31) Bq/L and (19) Bq/L in wet season and dry season respectively. The range of radon concentrations in river water is between (1.06) Bq/L and (1.21) Bq/L. This study has indicated that there is a flo
... Show More