Preferred Language
Articles
/
joe-202
Seismic Effects and Static Analysis for the Artificial Damped Outrigger Systems in Tall R.C Buildings
...Show More Authors

This paper studies the combination fluid viscous dampers in the outrigger system to add supplementary damping into the structure, which purpose to remove the dependability of the structure to lower variable intrinsic damping. It works by connecting the central core, comprising either shear walls or braced frames, to the outer perimeter columns.

     The modal considered is a 36 storey square high rise reinforced concrete building. By constructing a discrete lumped mass model, and using frequency-based response function, two systems of dampers, parallel and series systems are studied. The maximum lateral load at the top of the building is calculated, and  this load  will be applied at every floor of the building, giving a conservative solution. For static study Equivalent Lateral Force (ELF) was conducted. MATLAB software, has been used in this study.

     From analysis data, it is observed that the parallel system of dampers result lower amplitude of vibration and achieved more efficiently compared to the series system, and the horizontal displacement for each configurations by using MATLAB software is less than the analytical solution using a uniformly distributed load of 36 nodal point forces that divided the total height.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Depending the Total Quality Management Philosophy To Develop Lean Manufacturing Systems: Case Study In the General Company for Heavy Engineering Equipments
...Show More Authors

The continued acceleration in the business environment has led to the need for organizations great attention to quality applied in organizations to meet the needs of customers and stay in the market for as long as possible.

Search launched from the underlying problem is the presence of concentrations of defects and waste plaguing the company and to achieve the goal of the study detects the level of quality applied in the factory vessels and reservoirs of the General Company for Heavy Engineering Equipment, As well as calculate wastage rates occurring in the production process and find a relationship between the level of quality and ratios defective in each type of waste, it has been used quantitative meas

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Effects of local Infiltration of Bupivacaine in total hip and knee replacement for post - operative analgesia
...Show More Authors

Background: Pain is one of the most postoperative complications of surgical wound especially within first 24 hrs. leading to delay hospital discharge, stress gastritis and increasing blood pressure. As wound infiltration with long acting local anesthetic (bupivacaine) has been proved to be effective after orthopedic surgeries especially total hip and knee replacements.Objective: our study was designed to determine theeffectiveness of local infiltration of 0.5% of bupivacainebefore closure of surgical wounds in controllingpostoperative pain and improve patient’s outcome after totalhip and knee replacement surgeries in first 24hrspostoperative period.Methods: Twenty patients from class I (healthy patients) and class II (patients mild sys

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Bit Record Analysis for Bits Evaluating and Selection
...Show More Authors

The bit record is a part from the daily drilling report which is contain information about the type and the number of the bit that is used to drill the well, also contain data about  the used weight on bit  WOB ,revolution per minute RPM , rate of penetration ROP, pump pressure ,footage drilled and bit dull grade. Generally we can say that the bit record is a rich brief about the bit life in the hole. The main purpose of this research is to select the suitable bit to drill the next oil wells because the right bit selection avoid us more than one problems, on the other hand, the wrong bit selection cause more than one problem. Many methods are related to bit selection, this research is familiar with four of thos

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 27 2016
Journal Name
Newcastle University
The role of Intelligent Systems in Traditional Courtyard Houses in Baghdad, Iraq.
...Show More Authors

Publication Date
Sun May 18 2025
Journal Name
Discover Food
Analysis of the effectiveness of natural treatments for preserving apricots and the YOLOv7 application for early damage detection
...Show More Authors

Maintaining the quality of apricot fruits during storage is not an easy task due to the changes in their physical and chemical properties, so it is necessary to use less expensive, easy to apply, environmentally friendly, and safer preservatives to maintain the nutritional value of apricot. The damage to some fruits during storage can be a source of infection, which leads to the damage of healthy fruits more quickly, which requires building an intelligent model to detect damaged fruits. The aim of the research is to study the effect of immersing apricots in lemon juice once and sugar-water solution again on the quality properties of apricots, including sweetness, color, hardness, and water content. On the other hand, the YOLOv7 algorithm wa

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Civil Engineering Journal
Flexural Behavior of Composite GFRP Pultruded I-Section Beams under Static and Impact Loading
...Show More Authors

In this study, the effect of glass fiber reinforced polymer (GFRP) section and compressive strength of concrete in composite beams under static and low velocity impact loads was examined. Modeling was performed and the obtained results were compared with the test results and their compatibility was evaluated.‎ Experimental tests of four composite beams were carried out, where two of them are control specimen with 20 MPa compressive strength of concrete deck slab and 50 MPa for other. Bending characteristics were affected by the strength of concrete under impact loading case, as it increased maximum impact force and damping time at a ratio of 59% and reduced the damping ratio by 47% compared to the reference hybrid beam. Under stat

... Show More
Scopus (19)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Advances In Structural Engineering
CFRP Strengthening of RC Beams with Multiple Openings Subjected to Static and Impact Loads
...Show More Authors

The provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were

... Show More
Crossref (11)
Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Advances In Structural Engineering
CFRP Strengthening of RC Beams with Multiple Openings Subjected to Static and Impact Loads
...Show More Authors

The provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were

... Show More
View Publication
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sat Aug 21 2021
Journal Name
Engineering, Technology & Applied Science Research
A Comparison between Static and Repeated Load Test to Predict Asphalt Concrete Rut Depth
...Show More Authors

Rutting has a significant impact on the pavements' performance. Rutting depth is often used as a parameter to assess the quality of pavements. The Asphalt Institute (AI) design method prescribes a maximum allowable rutting depth of 13mm, whereas the AASHTO design method stipulates a critical serviceability index of 2.5 which is equivalent to an average rutting depth of 15mm. In this research, static and repeated compression tests were performed to evaluate the permanent strain based on (1) the relationship between mix properties (asphalt content and type), and (2) testing temperature. The results indicated that the accumulated plastic strain was higher during the repeated load test than that during the static load tests. Notably, temperatur

... Show More
View Publication
Crossref (10)
Crossref
Publication Date
Wed Jul 04 2018
Journal Name
Civil Engineering Journal
Behavior of Reinforced Reactive Powder Concrete Two-Way Slabs under Static and Repeated Load
...Show More Authors

This paper studies the behavior of reinforced Reactive Powder Concrete (RPC) two-way slabs under static and repeated load. The experimental program included testing six simply supported RPC two-way slabs of 1000 mm length, 1000 mm width, and 70 mm thickness. All the tested specimens were identical in their material properties, and reinforcement details except their steel fibers content. They were cast in three pairs, each one had a different steel fibers ratio (0.5 %, 1 %, and 1.5 %) respectively. In each pair, one specimen was tested under static load and the other under five cycles of repeated load (loading-unloading). Static test results revealed that increasing steel fibres volume fraction from 0.5 % to 1 % and from 1% to 1.5%,

... Show More
View Publication
Crossref (12)
Crossref