Preferred Language
Articles
/
joe-2009
SDPLL-Based Frequency Estimation of a Sinusoid in Colored Noise
...Show More Authors

The problem of frequency estimation of a single sinusoid observed in colored noise is addressed. Our estimator is based on the operation of the sinusoidal digital phase-locked loop (SDPLL) which carries the frequency information in its phase error after the noisy sinusoid has been acquired by the SDPLL. We show by computer simulations that this frequency estimator beats the Cramer-Rao bound (CRB) on the frequency error variance for moderate and high SNRs when the colored noise has a general low-pass filtered (LPF) characteristic, thereby outperforming, in terms of frequency error variance, several existing techniques some of which are, in addition, computationally demanding. Moreover, the present approach generalizes on existing work that addresses different methods of sinusoid frequency estimation involving
specific colored noise models such as the moving average (MA) noise model. An insightful theoretical analysis is presented to support the practical findings.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
The frequency of skin tumors and infections in patients with autoimmune diseases
...Show More Authors

KE Sharquie, AA Noaimi, ZT Burhan, Journal of Cosmetics, Dermatological Sciences and Applications, 2016 - Cited by 9

View Publication
Publication Date
Wed Oct 05 2016
Journal Name
Anbar Journal Of Agricultural Sciences
Estimation of genetic parameters in cowpea
...Show More Authors

An experiment was carried out in the fields of Agriculture College-Baghdad University during spring and autumn of 2015 by using a randomized complete blocks design with three replications. The first season hybridization was established among three pure cultivars of cowpea (Vigna uniguiculata L.) which: Ramshorn, California black eye and Rahawya in full diallel crosses according to Griffing with first method and fixed model (3 parents+ 3 diallel hybrids +3 reciprocal hybrids) and a comparison experiment was in autumn season. The result of statistical analysis showed that there was a significant difference among the parents and their hybrids for all the studied characters. The parent 1 was the higher for root nodules number , leaf number, pod

... Show More
Publication Date
Wed Aug 01 2018
Mixed Linearity Improvement Techniques for Ultra-wideband Low Noise Amplifier
...Show More Authors

<span>We present the linearization of an ultra-wideband low noise amplifier (UWB-LNA) operating from 2GHz to 11GHz through combining two linearization methods. The used linearization techniques are the combination of post-distortion cancellation and derivative-superposition linearization methods. The linearized UWB-LNA shows an improved linearity (IIP3) of +12dBm, a minimum noise figure (NF<sub>min.</sub>) of 3.6dB, input and output insertion losses (S<sub>11</sub> and S<sub>22</sub>)  below -9dB over the entire working bandwidth, midband gain of 6dB at 5.8GHz, and overall circuit power consumption of 24mW supplied from a 1.5V voltage source. Both UWB-LNA and linearized UWB-LNA designs are

... Show More
Scopus (1)
Scopus Crossref
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Radiological age estimation using third molars mineralization in a sample attending orthodontic clinics (A retrospective study)
...Show More Authors

Background: The evaluation of the chronological age is a practical method in crime investigation field that assists in identifying individuals to treat them as underage or adult. This study aimed to assess the stages of third molars mineralization in relation to chronological age of Iraqi individuals, determine the gender differences and arches (maxillary/mandibular) differences.

Materials and Methods: A total of 300 orthopantomograms of orthodontic patients were collected according to specific criteria and evaluated visually. The developmental stages of maxillary and mandibular third molars were determined according to Demirjian method. T

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Thu Aug 20 2026
Journal Name
Medical Journal Of Babylon
Frequency of DPYD Mutation in Patients with Adverse Effects of 5-Fluorouracil Therapy
...Show More Authors

Background: Fluoropyrimidines are widely used in the treatment of various solid tumors. One-third of cancer patients develop severe treatment-related toxicity. A part of fluoropyrimidine-related toxicity arises due to impaired activity of dihydropyrimidine dehydrogenase (DPD) caused by genetic variants in the DPYD gene. Objective: This study aims to determine the frequency of DPYD mutations among patients with adverse effects of 5-fluorouracil therapy. Materials and Methods: This cross-sectional study recruited 46 patients with 5-FU adverse effects. All demographic, clinical, and laboratory findings were recorded. Molecular testing was conducted to detect the DPYD mutation using the PGX-5FU StripAssay® kit, which identifies the IVS14 + 1G>

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design and Implementation for optical fiber communication system using frequency shift coding
...Show More Authors

In this research, optical communication coding systems are designed and constructed by utilizing Frequency Shift Code (FSC) technique. Calculations of the system quality represented by signal to noise ratio (S/N), Bit Error Rate (BER),and Power budget are done. In FSC system, the data of Nonreturn- to–zero (NRZ ) with bit rate at 190 kb/s was entered into FSC encoder circuit in transmitter unit. This data modulates the laser source HFCT-5205 with wavelength at 1310 nm by Intensity Modulation (IM) method, then this data is transferred through Single Mode (SM) optical fiber. The recovery of the NRZ is achieved using decoder circuit in receiver unit. The calculations of BER and S/N for FSC system a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Estimation of the average sample size and defective ratio In a finite individualized inspection with a practical application
...Show More Authors

The purpose of this research is to find the estimator of the average proportion of defectives based on attribute samples. That have been curtailed either with rejection of a lot finding the kth defective or with acceptance on finding the kth non defective.

The MLE (Maximum likelihood estimator) is derived. And also the ASN in Single Curtailed Sampling has been derived and we obtain a simplified Formula All the Notations needed are explained.

View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Proceedings Of International Conference On Computing And Communication Networks
Speech Age Estimation Using a Ranking Convolutional Neural Network
...Show More Authors

View Publication
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
The frequency of IgM-anti HAV in the sera of patients with hepatitis in Iraq
...Show More Authors

Three hundred and fifty five patients with hepatitis were investigated in this study all cases gave negative result with HBs Ag , IgM-anti HCV , IgM-anti HEV, IgM-anti HDV and anti-HIV tests . The frequency of IgM-anti HAV was 113 and the percentage was 32 % in all ages but when these patients divided into five groups dependent on ages. The highest percentage of IgM-anti HAV was (45%) in age <10 and the percentage declined with age increase till to 9% in age >41 year.

View Publication Preview PDF
Crossref (1)
Crossref