Preferred Language
Articles
/
joe-1985
Performance Evaluation of Two Stages Parallel Flow Indirect Evaporative Cooling with Aspen Pads in Baghdad Climate Conditions
...Show More Authors

This study delves into the realm of advanced cooling techniques by examining the performance of a two-stage parallel flow indirect evaporative cooling system enhanced with aspen pads in the challenging climate of Baghdad. The objective was to achieve average air dry bulb temperatures (43 oC) below the ambient wet bulb temperatures (24.95 oC) with an average relative humidity of 23%, aiming for unparalleled cooling efficiency. The research experiment was carried out in the urban environment of Baghdad, characterized by high temperature conditions. The investigation focused on the potential of the two-stage parallel flow setup, combined with the cooling capability of aspen pads, to surpass the limitations imposed by conventional cooling methods. The empirical findings underscored the capacity of the two-stage parallel flow configuration to achieve air-dry bulb temperatures surpassing the ambient wet bulb temperature.

Nonetheless, it was evident that an excessive application of water (exceeding 9 lpm) onto the aspen pads within the wet channels yielded adverse repercussions on the cooler's performance metrics, specifically in terms of wet bulb effectiveness and coefficient of performance. A range of air flows spanning from 150 CMH to 350 CMH was analyzed, revealing the influence of heightened air flow rates on the resultant dry bulb temperatures delivered by the cooling system. Notably, the peak wet-bulb effectiveness registered at 1.08, concurrently yielding a coefficient of performance measuring 7.8.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 16 2022
Journal Name
Clean Technologies
Performance Evaluation of Roughened Solar Air Heaters for Stretched Parameters
...Show More Authors

Artificial roughness applied to a Solar Air Heater (SAH) absorber plate is a popular technique for increasing its total thermal efficiency (ηt−th). In this paper, the influence of geometrical parameters of V-down ribs attached below the corrugated absorbing plate of a SAH on the ηt−th was examined. The impacts of key roughness parameters, including relative pitch p/e (6–12), relative height e/D (0.019–0.043), angles of attack α (30–75°), and Re (1000–20,000), were examined under real weather conditions. The SAH ηt−th roughened by V-down ribs was predicted using an in-house developed conjugate heat-transfer numerical model. The maximum SAH ηt−th was shown to be 78.8% as predicted under the steady-state condition

... Show More
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Jun 16 2022
Journal Name
Clean Technologies
Performance Evaluation of Roughened Solar Air Heaters for Stretched Parameters
...Show More Authors

Crossref (2)
Crossref
Publication Date
Sun May 28 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Performance Evaluation of three Indian Wheat Varieties Under Iraqi Environment
...Show More Authors

 The performance of the Indian wheat varieties (PBW34, PBW343 and WH542) was compared with the local varieties (Tamose – 2 and Abu Ghareeb).      The experiment was conducted during two seasons first 2000-2001 and second 2001-2002 at AL- Twaitha experimental station , middle of Iraq.         The results showed that (Tamose – 2) exceeded the other varieties in plant height and heading date in the two seasons, while WH542 gave the lowest plant height.  PBW34 variety showed a significant increase in 1000 grain weight followed by PBW343 in the second season. Moreover, PBW34 and PBW343 gave the highest average of 50 spike weight in the second season.&nbsp

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 01 2016
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Performance evaluation of heterogeneous network based on RED and WRED
...Show More Authors

Scopus (3)
Scopus
Publication Date
Sat Aug 18 2018
Journal Name
Journal Of Engineering And Applied Sciences
Performance Evaluation of Transport Protocols for Mobile Ad Hoc Networks
...Show More Authors

Mobile Ad hoc Networks (MANETs) is a wireless technology that plays an important role in several modern applications which include military, civil, health and real-time applications. Providing Quality of Service (QoS) for this application with network characterized by node mobility, infrastructure-less, limitation resource is a critical issue and takes greater attention. However, transport protocols effected influential on the performance of MANET application. This study provides an analysis and evaluation of the performance for TFRC, UDP and TCP transport protocols in MANET environment. In order to achieve high accuracy results, the three transport protocols are implemented and simulated with four different network topology which are 5, 10

... Show More
View Publication
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Evaluation of Three Phase Spray Direct Contact Heat Exchanger
...Show More Authors

 

The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Modeling and Simulation of Solar Module performance using Five Parameters Model by using Matlab in Baghdad City
...Show More Authors

This work presents the modeling of the electrical response of monocrystalline photovoltaic module by using five parameters model based on manufacture data-sheet of a solar module that measured in stander test conditions (STC) at radiation 1000W/m² and cell temperature 25 . The model takes into account the series and parallel (shunt) resistance of the module. This paper considers the details of Matlab modeling of the solar module by a developed Simulink model using the basic equations, the first approach was to estimate the parameters: photocurrent Iph, saturation current Is, shunt resistance Rsh, series resistance Rs, ideality factor A at stander test condition (STC) by an ite

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 16 2016
Journal Name
The Iraqi Journal Of Agricultural Sciences
PERFORMANCE EVALUATION OF FIELD AND GENETIC FOR SOME SIXTH RADIO GENERATION MUTANTS IN TOMATO
...Show More Authors

The study was conducted at the fields of the Department of Horticulture and Landscape Gardening, College of Agriculture, University of Baghdad " Abu Ghraib" during the growing seasons 2013-2014 to Evaluate the Vegetative growth , yield traits and genetic parameter of some tomato mutants. Results showed significantly increased of plant height in M6-2 mutant 245cm in Comparison with M6- 3 130 cm . M6-4 mutant significantly increasing of floral clusters 13 . Mutant M6-3 showed significantly increasing the average of, fruit weight 125.9g and plant yield 7.17 kg.plant-1 as comparison with M6-2 which showed decreasing of average of fruit weight and plant yield 79.40g and 4.38 kg.plant-1 respectively. Also results showed the highest Genetic variat

... Show More
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Prediction of Hydraulic Flow Units for Jeribe Reservoir in Jambour Oil Field Applying Flow Zone Indicator Method
...Show More Authors

The Jeribe reservoir in the Jambour Oil Field is a complex and heterogeneous carbonate reservoir characterized by a wide range of permeability variations. Due to limited availability of core plugs in most wells, it becomes crucial to establish correlations between cored wells and apply them to uncored wells for predicting permeability. In recent years, the Flow Zone Indicator (FZI) approach has gained significant applicability for predicting hydraulic flow units (HFUs) and identifying rock types within the reservoir units.

   This paper aims to develop a permeability model based on the principles of the Flow Zone Indicator. Analysis of core permeability versus core porosity plot and Reservoir Quality Index (RQI) - Normalized por

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Improve the Performance of PID Controller by Two Algorithms for Controlling the DC Servo Motor
...Show More Authors

The paper uses the Direct Synthesis (DS) method for tuning the Proportional Integral Derivative (PID) controller for controlling the DC servo motor. Two algorithms are presented for enhancing the performance of the suggested PID controller. These algorithms are Back-Propagation Neural Network and Particle Swarm Optimization (PSO). The performance and characteristics of DC servo motor are explained. The simulation results that obtained by using Matlab program show that the steady state error is eliminated with shorter adjusted time when using these algorithms with PID controller. A comparative between the two algorithms are described in this paper to show their effectiveness, which is found that the PSO algorithm gives be

... Show More
View Publication Preview PDF