This study objective is to identify the visual pollution in Karrada district main streets as an example of main streets in Baghdad, the public opinion about each pollutants, solutions to reduce and eliminate the pollution were suggested as well. In order to accomplish this objective different methods were used, 16 pollutants were selected, pictures of each pollutants were taken and a questioner were distributed randomly for 270 people to evaluate the public opinion with statistical methods. Garbage, their disposal and storage areas took the first two places as the highest offensive pollutants. The people showed that they find long lines of vehicles, debris and generators appearance ranked third, fourth and fifth respectively .This research showed that more than 70 percent of people are against the militarization of society and they consider any existence of heavy military machinery or personal is highly offensive issue. Other pollutants such as street sellers, beggars, and crossed wires considered as moderately
offensive. Car parking in inappropriate places, badly trimmed trees, large billboards in the streets and the buildings criteria considered slightly offensive. The shops billboards and cellular phone and internet towers were considered the least offensive pollutants. Major solutions is to enhance the municipality management in both planning and operation methods relayed to pollution removal, running awareness campaigns to educate the people about the visual pollution effects and how to reduce it and reduce the military appearances in the city
In this study, a new, rapid and sensitive batch and flow injection-merging zones spectrophotometric methods for the determination of hydroquinone in a pure material and in pharmaceutical preparation were proposed. These methods were based on the oxidative-coupling reaction of HQ with 2,4-dinitrophenylhydazine (DNPH) in the presence of sodium periodate and sodium hydroxide to form a dark brown water slouble dye that is stable and has maximum absorption at 530 nm, graphs of absorbance versus concentration show that Beer's low is obeyed over the concentration rang of 1-40 and 3-300 μg.ml-1 of hydroquinone, with detection limits of 0.162 and 0.510 μg.ml-1 of hydroquinone for batch and FIA methods, respectively. The optimized FIA system is
... Show MoreThe study of determing Uranium concentration in samples of teeth is the first of its kind in the Iraq . In this study Uranium concentration has been measured was (32) samples of child teeth distributed on the some of middle and south governorate of Iraq (Muthana – Dekar – Basrah – Najaf – Karbalah – Waset – Babel – Baghdad) . The Uranium concentration in teeth samples has been measured by using fission tracks registration in (CR-39) track detector that caused by the bombardment of (U235) with thermal neutrons falx from (24Am.Be) neutron source that has flux of (5x103n.cm-2S-1). The result obtained show that the Uranium concentrations in governorates were (0.18ppm), (0.172ppm), (0.160ppm), 0.150ppm) (0.89ppm), (0.07ppm) , (0.
... Show MoreThe aim of our current study was to identify the effect of particulate matter of both types (PM2.5 and PM10) resulting from hookah smoking on the hemopoietic system of workers (smokers) in closed cafes. This study included six stations (cafes) on the Rusafa side of Baghdad city and conducted a blood test that included a complete blood count (CBC). A multifunctional air quality detector measured both types of particulate matter in the morning and evening. The study included 30 men (workers and smokers) and 30 men (non-smokers), whose ages ranged from 20 to 40 years. The study found that smokers had an increase in white blood cells and red blood cells, as well as an increase in the percentage of hemoglobin (HGB), hematocrit (HCT), the mean co
... Show MoreThe effect of White Place Image ( Test Image ) A4 has been studied as a function of luminous intensity using the t tu un ng gs st te en n l la am mpp and web camera enet. It was found that the tungsten lamp gives almost even intensities for the three color band and lighting composite at low voltage .while at high voltage causes a fare from each other . The statistical characteristic(mean and stander deviation ) results for three colors composites RGB and lighting composites L showed that the mean and stander deviation increases with the increase of voltage possibly owing to the increase image resolution, which reflects the value of stander deviation for the blue band
... Show MoreNon Uniform Illumination biological image often leads to diminish structures and inhomogeneous intensities of the image. Algorithm has been proposed using Morphological Operations different types of structuring elements including (dick, line, square and ball) with the same parameters of (15).To correct the non-uniform illumination and enhancement biological images, the non-uniform background illumination have been removed from image, using (contrast adjustment, histogram equalization and adaptive histogram equalization). The used basic approach to extract the statistical features values from gray level of co-occurrence matrices (GLCM) can show the typical values for features content of biological images that can be in form of shape or sp
... Show MoreInternational satellite channels in Arabic are targeted to the region with their news bulletins and their innovative programs, attracting the interest of the Arab viewers in their news articles and programs with new ideas and methods as well as high technology in the production and synthesis of videos. Therefore, they work on framing the above, And the media policy that governs, so focused the problem of the study to try to answer the question of the President is how to frame the international satellite channels in Arabic to the phenomenon of terrorism? What are the aspects that are working to highlight and aspects that try to hide? The study adopted the survey methodology for the main news bulletins in the Russian channel today for the
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreDirect FIA methods for estimation of Naringenin (NG) in different samples were proposed. These methods are based on diazotization coupling reactions of two reagents: method (A) p-chloroaniline (PCA) and method (B) procaine hydrochloride (PRH) with NG in basic medium. Yellow dyes with maximum absorption at 416 and 415 nm were formed respectively. Calibration curves were constructed over different NG concentrations, linearity was from 1- 70 and 1- 40 µgmL-1 with detection limits of 0.55 and 0.24 µgmL-1 for (A) and (B) respectively. All analytical variables involved in the FIA procedure were evaluated and optimized. The established methods were successfully applied for the determination of NG in its supplements and u
... Show MoreA simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was
... Show More