A mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperature was varied from 35 0C to 55 0C in 5 0C increments. The study showed that R290 is the better replacement for R22 when the air conditioning system works under high ambient temperature. It has better performance as a drop in refrigerant. R407C has the closest performance to R22, followed by R410A.
Objective: To evaluate the psychological work environment's effect on the workers’ productivity in Baghdad
City industries at Al-Rusafa and Al-Karkh Sectors.
Methodology: A descriptive evaluation design is employed throughout the present study from May 25th 2012
through January 7
th
, 2014. A purposive (non probability) sample is selected for the study which includes (500)
workers from industries at AL-Russafa and AL-Kerch sectors in Baghdad City. A questionnaire is constructed to
gather data which may assist to achieve the objective of the study. Content validity of the instrument is
determined through eliciting the opinions of a panel of (10) experts and the reliability through a pilot study by
using intern
I found that it does not meet some of the requirements, including browsing and organizing structural elements, which is something in which the researcher found a scope for research, and from here she can formulate the problem of her research with the following question: Is there an actual need to develop user interface designs in the websites of Iraqi colleges of fine arts? The research included four chapters (the first chapter - the research problem - the second chapter (theoretical framework), which included three sections, the first is to identify the user interface, the second topic is the structural elements, and the third topic includes the rules of interface design and the dimensions of interaction), as well as the third chapter i
... Show MoreThis study aims to suggest an alternative to the use of quality agricultural soil in the brick industry (Iraq). The Late Miocene claystone bed in the Injana Formation in central Iraq was targeted through the study of 18 exposed sections that were sampled by using the trench sampling method. The claystones are characterized by quartz (36.4%) followed by calcite (32.8%), quartz (36.4%) feldspar (2.6%), gypsum (1.3%) and dolomite (0.7%), kaolinite (10.5%), illite (7.7%), chlorite (6.7%), palygorskite (6.0%) and montmorillonite (0.7%). New thermal mineral phases were formed at 950°C, including diopside (62.9%), quartz (18.4%), wollastonite (8.28%), akermanite (7.6%), Anorthite (6.25%), Nosean (4.9%), gehlenite (3.75%) and Lazurite (3.1
... Show MoreEvaluation of Dot. ELISA test for Diagnosis Visceral Leishmaniasis in Infected Children
Fire is one of the most critical risks devastating to human life and property. Therefore, humans make different efforts to deal with fire hazards. Many techniques have been developed to assess fire safety risks. One of these methods is to predict the outbreak of a fire in buildings, and although it is hard to predict when a fire will start, it is critical to do so to safeguard human life and property. This research deals with evaluating the safety risks of the existing building in the city of Samawah/Iraq and determining the appropriateness of these buildings in terms of safety from fire hazards. Twelve parameters are certified based on the National Fire Protection Association (NFPA20
The distress of moisture induced damage in flexible pavement received tremendous attention over the past decades. The harmful effects of this distress expand the deterioration of other known distresses such as rutting and fatigue cracking. This paper focused on the efficiency of using the waste material of demolished concrete to prepare asphalt mixtures that can withstand the effect of moisture in the pavement. For this purpose, different percentages of waste demolished concrete (0, 10, 20, 30, 50, 70 and 100) were embedded as a replacement for coarse aggregate to construct the base course. The optimum asphalt contents were determined depending on the Marshall method. Then after, two parameters were founded to evaluate the moisture
... Show MoreAbstract
This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season. The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per m
... Show More