A mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperature was varied from 35 0C to 55 0C in 5 0C increments. The study showed that R290 is the better replacement for R22 when the air conditioning system works under high ambient temperature. It has better performance as a drop in refrigerant. R407C has the closest performance to R22, followed by R410A.
This research focuses on the difficulties that face Oud's students' in the performance of Sharif Muheyddin Haider musical works. In addition, this research suggests solutions to overcome these difficulties for make it easier to play Haider's musical works. This research also addressed important topics of great relevance the title, problem and the research's aims. Moreover, Procedures of this research adopted the descriptive approach (content analysis) to attain the research's aims. Furthermore, results and discussions where covered, and conclusions of the appropriate academic solutions were achieved to overcome the performance difficulties of Haider's musical works among Oud's students'. At the end, the research presents a set of recomme
... Show MoreThis experimental study demonstrates the gable-reinforced concrete beams’ behavior with several number of openings (six and eight) and posts’ inclination, aimed to find the strength reduction in this type of beam. The major results found are: for the openings extending over similar beam length it is better to increase the number of posts (openings),
اعداد : أسرار عبد الزهراء علي - علاء الدين - ب. جواد حسن عودة عبد الله - جامعة بغداد جامعة بغداد كلية البصرة للعلوم والتكنولوجيا - كلية الإدارة والاقتصاد. كلية الإدارة والاقتصاد المركز الديمقراطي العربي – مجلة القانون الدستوري والعلوم الإدارية : العدد التاسع شباط – فبراير 2021 المجلد 3 ،
Two of the main advantages of segmental construction are economics, as well as the rapid construction technique. One of the forms of segmental construction, for structural elements, is the segmental beams that built-in short sections, which referred to segments. This research aims to exhibit a new technique for the fabrication of short-span segmental beams from wedge-shaped concrete segments and carbon fiber reinforced polymers (CFRP) in laminate form. The experimental campaign included eight short-span segmental beams. In this study, two selected parameters were considered. These parameters are; the number of layers of CFRP laminates and the adhesive material that used to bond segments to each other, forming short-span segmental be
... Show MoreIn recent years, the world witnessed a rapid growth in attacks on the internet which resulted in deficiencies in networks performances. The growth was in both quantity and versatility of the attacks. To cope with this, new detection techniques are required especially the ones that use Artificial Intelligence techniques such as machine learning based intrusion detection and prevention systems. Many machine learning models are used to deal with intrusion detection and each has its own pros and cons and this is where this paper falls in, performance analysis of different Machine Learning Models for Intrusion Detection Systems based on supervised machine learning algorithms. Using Python Scikit-Learn library KNN, Support Ve
... Show More

