A mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperature was varied from 35 0C to 55 0C in 5 0C increments. The study showed that R290 is the better replacement for R22 when the air conditioning system works under high ambient temperature. It has better performance as a drop in refrigerant. R407C has the closest performance to R22, followed by R410A.
The audience is one of the important practical elements in the theatrical show and its importance is not confined to its static activity as a receiver element only, rather it went beyond that issue as an effective and influential element in the proceedings of the show and the process of meaning construction, that it gains an active role in the construction and production of the connotation that influences and is influenced by the actor, where the communication channels are open between the two sides, consequently a kind of watching and joint interaction happens between them. Thus, it has become necessary for the actor to create a suitable environment for the onlookers in order for it to be an essential part of the show system. The
... Show MoreThe current study deals with the performance of constructed wetland (CW) incorporating a microbial fuel cell (MFC) for wastewater treatment and electricity generation. The whole unit is referred to as CW-MFC. This technique involves two treatments; the first is an aerobic treatment which occurs in the upper layer of the system (cathode section) and the second is anaerobic biological treatment in the lower layer of the system (anode section). Two types of electrode material were tested; stainless steel and graphite. Three configurations for electrodes arrangement CW-MFC were used. In the first unit of CW-MFC, the anode was graphite plate (GPa) and cathode was also graphite plate (GPc), in the second CW-MFC unit, the anode was stainless st
... Show MoreResearching performance audits according to the dimensions of financial sustainability in light of the scarcity of resources and economic and social transformations in the business environment is of utmost importance in the non-profit non-governmental organizations in achieving the goals and correct the path and address deviations, and help them in improving the outputs of processes and associated procedures and capacity The research was based on the hypothesis that the existence of a performance audit program in accordance with the dimensions of financial sustainability leads to the measurement of the commitment of the Olympic Committee. National Iraqi indicators of financial sustainability of the dimension of revenue in order to improv
... Show MoreA simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res
... Show MoreIn the petroleum industry, multiphase flow dynamics within the tubing string have gained significant attention due to associated challenges. Accurately predicting pressure drops and wellbore pressures is crucial for the effective modeling of vertical lift performance (VLP). This study focuses on predicting the multiphase flow behavior in four wells located in the Faihaa oil field in southern Iraq, utilizing PIPESIM software. The process of selecting the most appropriate multiphase correlation was performed by utilizing production test data to construct a comprehensive survey data catalog. Subsequently, the results were compared with the correlations available within the PIPESIM software. The outcomes reveal that the Hagedorn and Brown (H
... Show MorePhotonic Crystal Fiber Interferometers (PCFIs) are greatly used
for sensing applications. This work presents the fabrication and
characterization of a relative humidity sensor based on Mach-
Zehnder Interferometer (MZI), which operates in reflection mode.
The humidity sensor operation based on the adsorption and
desorption of water vapour at the silica-air interface within the PCF.
The fabrication of this sensor is simple, it only includes splicing and
cleaving the PCF with SMF.PCF (LMA-10) with a certain length
spliced to SMF (Corning-28).
The spectrum of PCFI exhibits good sensitivity to humidity
variations. The PCFI response is observed for a range of humidity
values from (27% RH to 85% RH), the positi
Optimized Link State Routing Protocol (OLSR) is an efficient routing protocol used for various Ad hoc networks. OLSR employs the Multipoint Relay (MPR) technique to reduce network overhead traffic. A mobility model's main goal is to realistically simulate the movement behaviors of actual users. However, the high mobility and mobility model is the major design issues for an efficient and effective routing protocol for real Mobile Ad hoc Networks (MANETs). Therefore, this paper aims to analyze the performance of the OLSR protocol concerning various random and group mobility models. Two simulation scenarios were conducted over four mobility models, specifically the Random Waypoint model (RWP), Random Direction model (RD), Nomadic Co
... Show MoreThe efficiency of internal combustion engines (ICE) is usually about thirty percent of the total energy of the fuel. The residual energy is lost in the exhaust gas, the lubrication, and the cooling water in the radiators. Recently much of the researcher’s efforts have focused on taking advantage of wasted energy of the exhaust gas. Using a thermoelectric generator (TEG) is one of the promising ways. However, TEG depends entirely on the temperature difference, which may be offered by the exhaust muffler. An experimental test has been conducted to study the thermal performance of a different muffler internal design. The researchers resort to the use of lost energy in an ICE using TEG, which is one of the ways to take adv
... Show More