Preferred Language
Articles
/
joe-1912
Improving Thermal Performance in the University Classrooms
...Show More Authors

Universities are among spaces where it's important to ensure thermal comfort in indoor spaces, improving the occupants' well-being and productivity. The problem of the research was to study appropriate glazing systems for the spaces of the University of Baghdad because glazing systems are one of the most important elements of the indoor environments, and it has a major impact on the thermal performance of buildings. Glass is one of the most seasoned materials that are most utilized in the design. Since it is a diaphanous material, it allows sunlight to enter the building, increasing the space's temperature, cooling loads, and energy consumption in summer. The research followed the experimental method by studying and testing(conventional, advanced, and photovoltaic glazing)by Revit and Onyx Solar analysis in the Architectural Department classes to find the appropriate type of glazing in the spaces of hot, dry areas. The results showed that advanced glazing is the best by reducing the cooling loads andincreasingthermal performance quality. Photovoltaic glazing showed its efficiency in filling part of the electrical energy needs within the spaces of the Architectural department.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 24 2018
Journal Name
Aip Conference Proceedings
The study effect of weight fraction on thermal and electrical conductivity for unsaturated polyester composite alone and hybrid
...Show More Authors

In this research prepared two composite materials , the first prepared from unsaturated polyester resin (UP) , which is a matrix , and aluminum oxide (Al2O3) , and the second prepared from unsaturated polyester resin and aluminum oxide and copper oxide (CuO) , the two composites materials (Alone and Hybrid) of percentage weight (5,10,15)% . All samples were prepared by hand layup process, and study the electrical and thermal conductivity. The results showed decrease electrical conductivity from (10 - 2.39) ×10-15 for (Up+ Al2O3) and from (10 - 2.06)×10-15 for (Up+ Al2O3+ CuO) .But increase thermal conductivity from( 0.17 - 0.505) for (Up+ Al2O3) and from (0.17 - 0.489) for (Up+ Al2O3+ CuO).

View Publication
Scopus (20)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sun Jan 02 2011
Journal Name
Journal Of Educational And Psychological Researches
Mental Health and Its Relationship with Shyness for University Students
...Show More Authors

This study aimed to show the relationship between mental health and shyness for university students in Baghdad and Al – Mustansiria university which its subject was (200) students  ,          ( 100) males and  ( 100) females , Mental Health scale which is constructed by (Al – Janabi 1991) and developed by (Hassan 2006) was used for this aim  ,The scale of shyness was built according to a questioner to the students and according to previous publications and studies .

Multiple regulation analysis step - wise was used for data analysis in order to identify the possibility to find single or couple indications for the independent variable (mental

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 01 2018
Journal Name
Journal Of Educational And Psychological Researches
Personal Efficacy And Its Relationship With Mindfulness Among University Students
...Show More Authors

The study seeks to examine the level of personal efficacy and its relation to mental alertness among university students. Besides, the statistically significant differences in regard of students' gender, and the correlation between male and female. To do this, the researcher adopted two scales: one to measure the personal efficacy which was made up by (abed al-jabaar, 2010) included (26) items, and the other to measure the mental alertness that designed by (abed Allah, 2012) included (36) items. A total of (120) student were selected randomly from three-different colleges at the Al-Mustansiriyah University for the academic year 2016-2017. The findings revealed there are no significant differences among students in regard of the personal

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Educational And Psychological Researches
Existential frustration and its relation with recrimination among university students
...Show More Authors

The study aims to identify the level of existential frustration and the level of recrimination among the students of universities, identify the statistical differences between the existential frustration and recrimination based on gender, and finally, identify the correlation between the existential frustration and recrimination. To do this, the researcher adopted the existential frustration scale of ( al-saaedi, 2009) that consisted of (43) item, he also adopted the recrimination scale of ( al-zugeibi,2008) which composed of (31) item. The total sample was (120) male and female student were chosen randomly from four colleges within the university of Baghdad for the academic year ( 2015-2016). The results revealed that the targeted sampl

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
The Study of properties structure and some optical properties forcopper Oxid (CuO) Thin film prepared by thermal evaporation in Vacume
...Show More Authors

in this paper copper oxide (cuO thin films were prepared by the method of vacum thermal evaporation a pressure.

View Publication Preview PDF
Publication Date
Thu Aug 04 2022
Journal Name
Journal Of Nanomaterials
Thermal Management of the Melting Process in a Latent Heat Triplex Tube Storage System Using Different Configurations of Frustum Tubes
...Show More Authors

In this study, the energy charging mechanism is mathematically modeled to determine the impact of design modifications on the thermofluidic behavior of a phase change material (PCM) filled in a triplex tube containment geometry. The surface area of the middle tube, where the PCM is placed, is supported by single or multi-internal frustum tubes in vertical triplex tubes to increase the performance of the heating and cooling of the system. In addition to the ordinary straight triplex tubes, three more scenarios are considered: (1) changing the middle tube to the frustum tube, (2) changing the inner tube to the frustum tube, and (3) changing both the internal and central tubes to the frustum tubes. The impact of adopting the tube desig

... Show More
View Publication
Scopus (54)
Crossref (49)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Mechanical and Thermal Properties of Epoxy-Graphite Composites
...Show More Authors

This search study the effect of particle size of graphite on the mechanical and thermal properties of epoxy composites, where graphite adopted with particle sizes (45,53,75) ?m, respectively, and the percentages by weight (0,1,3,5,7,9)% for each size of this three particle sizes.Mechanical properties represented by the bending (three-point bending) and through which the conclusion is bending stress and modulus of elasticity, thermal properties were either through thermal conductivity tests.The results showed that the ratio(1%) is the maximum value of bending stress at the three particle size and the (45 ?m) is the maximum.Thermal conductivity result show is the maximum value at ratio (1%) of particle size(53 ?m)

View Publication Preview PDF
Crossref
Publication Date
Tue Sep 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Treatment of Slack Wax by Thermal Cracking Process
...Show More Authors

This work deals with thermal cracking of slack wax produced as a byproduct from solvent dewaxing process of medium lubricating oil fraction in AL-Dura refinery. The thermal cracking process was carried out at a temperature ranges 480-540 ºC and atmospheric pressure. The liquid hourly space velocity (LHSV) for thermal cracking was varied between 1.0-2.5 . It was found that the conversion increased (61 - 83) with the increasing of reaction temperature (480 - 540) and decreased (83 - 63) with the increasing of liquid hourly space velocity (1.0 - 2.5).
The maximum gasoline yield obtained by thermal cracking process (48.52 wt. % of feed) was obtained at 500 ºC and liquid hour space velocity 1 . The obtaining liquid product at the best op

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 28 2021
Journal Name
Journal Of Economics And Administrative Sciences
The Impact of Entrepreneur Decision Making on Ambidexterity Performance: An Applied Research in the Oil Products Distribution Company/ aldawra
...Show More Authors

 

The research aims to determine the role of Entrepreneur decision-making in its dimensions in improving the activities of Ambidexterity performance in its dimensions in the researched company. The importance of the research is also evidenced by assisting the oil products distribution company/session in directing the interest of the researched company because it has a prominent role in the Iraqi industrial community for the Entrepreneur decision-making variable that Contributes to building sustainable competitive advantage. This will happen when the company has an Entrepreneur orientation and a good strategic plan is built by the smart leaders in the researched company The researcher adopted the method of the analyti

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement
...Show More Authors

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns f

... Show More
View Publication Preview PDF