Universities are among spaces where it's important to ensure thermal comfort in indoor spaces, improving the occupants' well-being and productivity. The problem of the research was to study appropriate glazing systems for the spaces of the University of Baghdad because glazing systems are one of the most important elements of the indoor environments, and it has a major impact on the thermal performance of buildings. Glass is one of the most seasoned materials that are most utilized in the design. Since it is a diaphanous material, it allows sunlight to enter the building, increasing the space's temperature, cooling loads, and energy consumption in summer. The research followed the experimental method by studying and testing(conventional, advanced, and photovoltaic glazing)by Revit and Onyx Solar analysis in the Architectural Department classes to find the appropriate type of glazing in the spaces of hot, dry areas. The results showed that advanced glazing is the best by reducing the cooling loads andincreasingthermal performance quality. Photovoltaic glazing showed its efficiency in filling part of the electrical energy needs within the spaces of the Architectural department.
Student performance may influence by several factors in all his study levels such as primary school, intermediate school and even in his college; some of these factors are psychological factors, social factors, and the factors which correlate with student environment.
In this paper we study some of these factors to discover their influence by using canonical correlation analysis to analyze the data. Many conclusions are discovered to help who focuses student performance or to make it pest in future.
CdS films were prepared by thermal evaporation at pressure (10-6torr) of 1μm thickness onto glass substrate by using (Mo) boat. The optical properties of CdS films, absorbance, transmittance and reflectance were studied in wavelength range of (300-900)nm. The refractive index, extinction coefficient, and absorption coefficient were also studied. It's found that CdS films have allowed direct and forbidden transition with energy gap 2.4eV and 2.25eV respectively and it also has high absorption coefficient (α >104cm-1).
Abstract
The leases, are regarded as one of the most controversial accounting issues in recent years, since they represents one of the important sources of funding, which may be exploited by the tenant as off- Balance sheet Financing , which negatively affects the quality of financial reporting. The Financial Accounting Standards Board (FASB) and the International Accounting Standards Board (IASB) have "significant" interest in accounting for leases . FASB issued Statement of Financial Accounting Standards 13 on lease contracts in 1976 and IASB issued IAS 17 in 1980, which was amended in 1997 and IFRS 16, issued in January 2016, which will be effective on January 1, 2019 , to solve
... Show MoreExperiments have been conducted to study the local and average heat transfer by mixed
convection for hydrodynamically fully developed, thermally developing and fully developed
laminar upward air flow in an inclined annulus with adiabatic inner cast iron tube and uniform
heated outer aluminum tube with an aspect ratio ( Ω = 0.72) and (L/Dh≈40) for both calming and
test sections). A wide range of Reynolds number from 859 to 2024 has been covered, and heat
flux has been varied from 159 W/m2 to 812 W/m2 (these values of heat flux and Reynolds
number gave Richardson number range from 0.03 to 0.٣٨), with angles of annulus inclination
φ =0o (horizontal position), φ =60o (inclined position), and φ =90o (vertical posi