In this work, a flat-plate solar air heater (FSAH) and a tubular solar air heater (TSAH) were designed and tested numerically. The work investigates the effect of increasing the contact area between the flowing air and the absorber surface of each heater and predicts the expected results before the fabrication of the experimental rig. Three-dimensional two models were designed and simulated by the ANSYS-FLUENT 16 Program. The solar irradiation and ambient air temperature were measured experimentally on December 1st 2022, at the weather conditions of Baghdad City- Iraq, at three air mass flow rates, 0.012 kg/s, 0.032 kg/s, and 0.052 kg/s. The numerical results showed the advantage in the thermal performance of the TSAH in comparison to the FSAH, represented by better air temperature difference, better heat transfer from the absorber to air, and better thermal efficiency. The TSAH has a higher thermal efficiency than the FSAH by 7 %, 19 % °C, and 22 % at 0.012 kg/s, 0.032 kg/s, and 0.052 kg/s, respectively. The improvement of the thermal characteristics of the TSAH can be referred to as the increment in the heat transfer contact area between the absorber and the flowing air.
The effect of fiber volume fraction of the carbon fiber on the thermal conductivity of the polymer composite material was studied. Different percentages of carbon fibers were used (5%, 10%, 15%, 20%, and 25%). Specimens were made in two groups for unsaturated polyester as a matrix and carbon fibers, first group has parallel arrangement of fibers and the second group has perpendicular arrangement of fibers on the thermal flow, Lee's disk method was used for testing the specimens. This study showed that the values of the of thermal conductivity of the specimens when the fibers arranged in parallel direction was higher than that when the fibers arranged in the perpendicular direction
 
... Show MoreThis research Sought to identify the correlation relationships and the impact of each of the job description and perceived organizational support, Excellent Job performance of the heads of academic departments in the faculties of the University of Sulaymaniyah Iraqi Kurdistan Region, totaling (89) as President, and to achieve this was Default plan includes research variables as well as the formulation of a number of preparation fundamental assumptions, and researchers used a questionnaire for this purpose as a tool head of the collection of data and information, as it was distributed (80) copies, and the number of retrieved them (76) a copy of a valid statistical analysis, as well as conducting personal i
... Show MoreThe topic of strategic intelligence is considered as important topics that acquires the attention of organizations, Because of its role in supplying the decision-making centers by strategic ideas according to the opportunities and threats facing the organization, in an effort to improve the performance of their organizations to reach the high performance organization.
A lot of organizations lack to strategy guides the strategic intelligence towards achieving high performance organization.
This research aims to determine the level of strategic intelligence that characterized the leaders of diseases and kidney transplant center in Medicine city. What is the application level of the
... Show MoreAssessing performance efficiency is critical to the management need for oversight, planning, and continuous periodic evaluation of the multiple activities of Northern Cement State Company in order to determine the level of achievement of the objectives set, and to correct the deviations and delays that the evaluation shows and limitation of liability. What cannot be measured cannot be managed. The aim of this research is to highlight the impact of using BSC, financial and non-financial, to give comprehensive and clear picture of the company's performance and to measure the quality of its performance by using six-sigma and the level of deviations in achieving the planned goals. Therefore, four-key hypotheses were formulated for th
... Show MoreThe thermal properties (thermal transfer and thermal expansion coefficient) of the enhanced epoxy resin (MWCNT / x-TiO2) were studied by weight ratios with the values (0%, 3%, 5%, 7% and 10%) and a constant ratio of 3% of MWCNT. The ultrasonic technology was used to prepare the neat and composites which were then poured into Teflon molds according to standard conditions. Thermo-analyzer sensor technology was used to measure thermal transfer (thermal conductivity, thermal flow, thermal diffusion, thermal energy and heat resistance). The thermal conductivity, flow, and thermal conductivity values were increased sequentially by increasing the weight ratio of the filler while the results of stored energy values an
... Show MoreNowadays, most of the on-chip plasmonic single-photon sources emit an unpolarized stream of single photons that demand a subsequent polarizer stage in a practical quantum cryptography system. In this paper, we numerically demonstrated the coupling of the light emitted from a quantum emitter (QE) at 700 nm wavelength to the propagation mode supported by an on-chip hybrid plasmonic waveguide (HPW) polarization rotator. Our results proved that the light emitted is linearly polarized at 0º, 45º/−45º, and 90º with propagation lengths of 5 μm, 3.3 μm, and 3.9 μm, respectively. Moreover, high power-conversion efficiency was obtained from an applied transverse magnetic (TM) mode (0º-polarization) to a transverse electric (TE) (90º-polari
... Show MoreThe present work aimed to examine the nature and degree of the cross-correlations among three different ionospheric indices: these are Optimum Working Frequency (OWF), Highest Probable Frequency (HPF), and Best Usable Frequency (BUF). VOCAP and ASASPS models were adopted to determine the datasets of the selected ionospheric indices. The determination was made for different transceiver stations that provide certain HF connection links during the minimum and maximum years of solar cycle 24, 2009 and 2014, respectively. Matlab program was implemented to produce the geodesic parameters for the selected transceiver stations. The determination was made for different path lengths (500, 1000, 1500, and 2000) Km and bearings (0o, 45
... Show More